63 resultados para Diagnostic imaging services

em Repositório Institucional UNESP - Universidade Estadual Paulista "Julio de Mesquita Filho"


Relevância:

90.00% 90.00%

Publicador:

Resumo:

The incidence of encephalic tumors in dogs and cats has increased in recent years due to the constant advancement of methods of specialist Diagnostic Imaging: Magnetic Resonance Imaging (MRI) and Computed Tomography (CT), used in small animals. These tools, which were distant in the past, are now becoming increasingly important as an additional aid to the identification of tumor processes in the Central Nervous System. The objective, of the present study, was describe imaging findings obtained in 32 cases of encephalic tumors, through techniques of CT and MR imaging procedures during the years 2004 to 2011. Were diagnosed 19/32 by MRI and 13/32 by CT, being the most affected breed Boxer (9/32), the mean age was 10 years.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The Quality Control services for diagnostic imaging is essential to ensure that their activities occur as planned. Procedures are aimed at a positive cost-benefit to the institution and risk-benefit to the patients. And this requires trained and skilled professionals working with high technology equipment. The company PhyMED Consultores em Física Médica e Radioproteção Ltda., a Pioneer in the field of Medica Physics in Rio Grande do Sul, is dedicated to providing consulting services in healthcare. Physicists are experienced working in many areas of diagnostic imaging

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The paper presents the radiometric parameters determined by the medical physicist during routine radiotherapy planning service in cases of breast cancer . The contours of the breast volume in patients undergoing radiation breast tumors at the Hospital das Clinicas, Faculty of Medicine , UNESP, Botucatu ( HCFMB ) during the year 2012 were analyzed . In order to analyze the influence of physical and radiometric parameters for the determination of the dose distribution of irradiated breast volume , four measurements of isodose curves were prepared in four different heights breast , and compared with the isodose curves plotted computationally . In the routine of planning , the medical physicist must determine the isodose curve that gives the best dose distribution homogeneity in the irradiated volume . The choice of the treatment plan can be done by dedicated computer systems , which require significantly costly investments available services having better financial support . In the Service of Medical Physics , Department of Radiotherapy , HC FMB , we use a two-dimensional software for determination of isodose curves , however , this software is out of date and frequently becomes inoperable due to the lack of maintenance and it is a closed system without feasibility of interference from computer professionals . This fact requires manual preparation of isodose curves , which are subject to uncertainties due to the subjectivity in the clinical interpretation of medical radiation oncologist and medical physicist responsible for planning , plus dispendiar significant calculation time . The choice of the optimal isodose curve depends on the energy of the radiation beam , the geometry and dimensions of the irradiated area . The contours of the breast studied in this work evaluations showed that , for a given energy input , such as the energy of 1.25 MeV of gamma radiation Unit Telecobaltoterapia , the determination of the percentage depth dose ( PDP ) ...

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Scintimammography using Tc-99m-sestamibi is a noninvasive and painless diagnostic imaging method that is used to detect breast cancer when mammography is inconclusive Because of the advantages of labeling v '7,ith Tc-99m-sestamibi and its high efficiency in detecting carcinomas, it is the most widespread agent for this purpose Its accumulation in the tumor has multifactorial causes and does not depend on the presence of architectural distortion or local or diffuse density variation in the breast The objective of tfiis study was to evaluate the accuracy of scintimammography 1 for detecting breast cancer One hundred and fifty-seven patients presenting 158 palpable and non-palpable breast nodules were evaluated Three patients were male and 154 were female, aged between 14 and 81 years All patients underwent scintimammography, and the nodule was subjected i to cytological or histological study, i e, the gold standard for diagnosing cancer One hundred and eleven malignant and 47 benign nodules were detected, with predominance of ductal carcinomas (n=94) and fibroadenoma/fibrocysiic condition (n=11/n=11), respectively The mean size was 3 11 cm (7-10 cm) among the malignant nodules and 2 07 cm among the benign nodules (0 5-10 cm) The sensitivity, specificity, positive predictive value, negative predictive value and accuracy were 89, 89, 95, 78 and 89%, respectively Analysis on the histological types showed that the technique was more effective on tumors that were more aggressive, such as ductal carcinoma In this study, Tc-99m-sestamibi scintim immography was shown to be an important tool for diagnosing breast cancer when mammography was inconclusive

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

80.00% 80.00%

Publicador:

Resumo:

OBJETIVO: Avaliar quantitativamente as mudanças da posição palpebral e as medidas da fenda palpebral de indivíduos acima dos 50 anos. MÉTODOS: Estudo observacional, tendo sido avaliados 325 indivíduos, com idade acima de 50 anos, segundo distância intercantal, largura e altura da fenda palpebral, ângulo palpebral externo e interno, distância entre o reflexo pupilar e a margem da pálpebra superior (distância reflexo-margem) e a área total da fenda palpebral. Utilizou-se filmadora Sony Lithium para obtenção das imagens digitais, com o indivíduo fixando um objeto a 1 metro de distância, sendo as imagens transferidas posteriormente para computador McIntosh G4 e processadas pelo programa NIH 1.58. Os dados foram submetidos à análise estatística. RESULTADOS: Os participantes apresentavam dermatocálase (96,5%), ptose do supercílio (60,8%), prolapso de gordura orbital (50,0%) ou ptose palpebral (39,1%). As alterações foram bilaterais em 68,8% dos indivíduos. A distância intercantal aumentou com a idade; a largura da fenda palpebral, a distância reflexo-margem e a medida do ângulo externo diminuíram nos mais idosos. As diferenças foram mais significativas quando os olhos foram estudados separadamente. CONCLUSÃO: A distância intercantal aumenta, ao passo que a largura da fenda palpebral, a distância reflexo-margem e a área total da fenda palpebral diminuem com o aumento da idade.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Descreveu-se a anatomia da região cervical de equinos adultos, com base em imagens obtidas no exame de tomografia computadorizada helicoidal realizado em peças anatômicas de equinos adultos. A tomografia computadorizada foi o método de imagem diagnóstica de escolha e possibilita as reconstruções de imagens tridimensionais e em outros planos anatômicos, como sagital e coronal. Todas as imagens foram adquiridas e avaliadas em filtro e janela para tecido ósseo. Observaram-se diferenças anatômicas e as particularidades normais das vértebras, principalmente da região occipitoatlantoaxial, a qual apresenta maior incidência de alterações.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Purpose: the purpose of this in vivo study was to compare the accuracy of primary incisor length determined by direct digital radiography (straight-line measurement and grid superimposition) and measurement of the actual tooth length. Methods. Twenty-two primary maxillary incisors that required extractions were selected from 3- to 5-year-old children. The teeth were radiographed with an intraoral sensor using the long cone technique and a sensor holder (30-cm focus-to-sensor distance). The exposure time was 03 seconds. Tooth length was estimated by using straight-line and grid measurements provided by the distance measurement feature of the Computed Dental Radiography digital dental imaging system. The actual tooth length was obtained by measuring the extracted tooth with G digital caliper. Data were analyzed statistically by Pearson's correlation coefficient and a paired t test. Results: There were statistically significant differences (P=.007) between the 2 measurement techniques and between the actual tooth lengths and grid measurements. There was no statistically significant difference (P=38) between straight-line measurements and actual tooth lengths, showing that the straight-line measurements were more accurate. Underestimation of the actual tooth length, however, occurred in 45% of the straight-line measurements and in 73% of the grid measurements. Conclusion: It is possible to determine primary tooth length in digital radiographs using onscreen measurements with 0 reasonable degree of accuracy.

Relevância:

80.00% 80.00%

Publicador:

Relevância:

80.00% 80.00%

Publicador:

Resumo:

BACKGROUND: Ultrasonography (US), Computed Tomography (CT), and Magnetic Resonance imaging (MR) were compared for the staging of renal tumors. The differences between these imaging techniques were also studied for their ability to detect adenopathies, vascular invasion, distant intra-abdominal metastases, and particularly adjacent organ invasion. METHODS: Thirty-one patients with solid or complex renal masses were prospectively studied using US, CT, and MR. Differences between the results obtained were studied using the COCHRAN G test and the McNEMAR test. The sensitivity and specificity of each diagnostic technique were compared against a gold standard of the surgical and histopathological findings. RESULTS: The following sensitivities were obtained: For the detection of adenopathy, US 63.6%, CT and MR 90.9%. For vascular invasion, US 42.8%, CT and MR 85.7%. For the adjacent organ invasion, US 28.5%, CT 85.7%, and MR 71.4%. Some of the criteria that suggest invasion of adjacent structures include: the envelopment of the adjacent structures by the tumor, tumor extension into the adjacent structures with an irregular appearance, and alterations in shape, size, and density of adjacent structures. Loss of fat planes between the tumor and adjacent structures is not a sign of tumor invasion. CONCLUSIONS: Significant differences were found in the detection capacity of US in relation to CT and MR, which were similar. All three techniques were highly sensitive and specific only in the detection of distant abdominal metastases. In addition to the accuracy of these diagnostic modalities for the detection and staging of tumors, invasiveness, risks and cost should be considered in relation to relative costs and benefits.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

A left paravertebral mass discovered incidentally on routine examination in a 39-year-old woman is described. Computerized tomography studies revealed a 7 × 6 cm, well circumscribed, noncalcified soft tissue mass with lobular borders abutting the left inferior pulmonary vein and descending aorta. It was not possible to determine the exact anatomic location of the mass based on the imaging studies as both peripheral lung tumors and posterior mediastinal lesions may exhibit the imaging findings described here. At thoracotomy, the mass was seen to be well circumscribed, focally attached to the pleura but without involvement of lung parenchyma, and situated in the left posterior mediastinum. On histological examination, the lesion showed the classical features of myxopapillary ependymoma. Immunohistochemical studies confirmed this impression by demonstrating strong positivity of the tumor cells for S-100 protein, glial fibrillary acidic protein, and CD99 and negative staining with other differentiation markers. A review of the literature with a discussion of the histologic and radiologic differential diagnosis of these lesions is presented. © 2006 Elsevier Inc. All rights reserved.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Objective: the current study aims at following up radiographically the evolution of the midpalatal suture during the expansion procedure since the opening of the suture until bone formation. Methods: the sample comprised 38 patients in the mixed dentition stage submitted to the rapid palatal expansion protocol of the Hospital for Rehabilitation of Craniofacial Anomalies. Results: it was observed an individual variation on the period of bone ossification of the midpalatal suture, which justifies the radiographic follow-up as determinant for the appliance removal. Due to long-term post-treatment stability, the expander should be removed after the new suture is completely formed. Conclusions: the findings show that it is necessary more than three months for the complete reorganization of the midpalatal suture during the passive phase of the rapid palatal expansion.

Relevância:

80.00% 80.00%

Publicador:

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Recurrent venous thromboembolism is a significant problem leading to increased morbidity and mortality. It has a high impact on patients' quality of life and imposes a great financial burden on society. Cumulative recurrence has been reported as 40% at 10 years, while the chance of developing postthrombotic signs and symptoms in the lower extremities almost quadruples when ipsilateral. There is also a higher chance of developing pulmonary hypertension. Important factors for recurrence are unprovoked episodes of deep vein thrombosis, malignancy and older age. The evidence for other factors is controversial. Accurate diagnosis and treatment tailored to the patients' history, thrombotic events and risk factors are necessary to optimize management and prevent recurrence.