274 resultados para Dental Impression Materials

em Repositório Institucional UNESP - Universidade Estadual Paulista "Julio de Mesquita Filho"


Relevância:

100.00% 100.00%

Publicador:

Resumo:

STATEMENT OF PROBLEM: Difficulties in sterilizing impressions by traditional methods have led to chemical disinfection as an alternative, and some studies have shown that disinfectants may adversely affect impressions. PURPOSE: This study investigated the effect of disinfection methods on the dimensional stability of 6 elastomeric materials. MATERIAL AND METHODS: Impression materials were submitted to the following treatments: immersion in 5.25% sodium hypochlorite solution for 10 minutes, immersion in 2% glutaraldehyde solution for 30 minutes, and no immersion (control). After treatments, impressions were poured, and respective stone casts were measured with a Nikon Profile projector and compared with the master model. RESULTS: The elastomeric materials had different reproduction capacities, and the disinfecting treatments did not differ from the control.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this work the color dependence of resin composites with the background color was evaluated. The objective was to measure since what thickness the color of the sample stops being influenced by the color of the background over which the resin is placed and the methodology used in experiment was based in analyzing the contrast of digital images of the sample over a black background. The results shown that since 0.8 mm the images contrast becomes almost constant; it prove that since this thickness the color of resin composite depends on the optical resin properties only. The experiment was repeated under three conditions of luminosity to evaluate the influence of it on the image contrast and the results obtained were identical.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose: This study evaluated the influence of surface abrasion of transfer copings to obtain a precise master cast for a partially edentulous restoration with different inclinations. Materials and Methods: Replicas (N = 30) of a metal matrix (control group) containing two implants at 90° and 65° in relation to the benchtop were obtained using a polyether impression material and three impression techniques: square impression copings splint with dental floss and autopolymerizing acrylic resin (TRS), square impression copings abraded with aluminum oxide (TA), and square impression copings abraded with aluminum oxide and adhesive-coated (TAA). The replicas obtained in type V stone were digitalized, and the images were exported to AutoCAD software to perform the readings of possible degree alterations in implant inclinations. The results were submitted to analysis of variance (ANOVA) and Tukey test (α < 0.05). Results: Comparing the techniques with regard to the 90° implant inclination, no statistical difference was observed between the three techniques and the control group. Analyzing the three techniques with regard to the 65° implant inclination, no significant difference was seen between technique TA and the control group. Conclusions: Technique TA presented more accurate master casts than TRS and TAA techniques. The angulated implant (65°) tended to generate more imprecise master casts than implants perpendicular to the surface. © 2008 by The American College of Prosthodontists.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objectives: This in vitro study compared the dimensional accuracy of stone index (I) and three impression techniques: tapered impression copings (T), squared impression copings (S) and modified squared impression copings (MS) for implant-supported prostheses. Methods: A master cast, with four parallel implant abutment analogs and a passive framework, were fabricated. Vinyl polysiloxane impression material was used for all impressions with two metal stock trays (open and closed tray). Four groups (I, T, S and MS) were tested (n = 5). A metallic framework was seated on each of the casts, one abutment screw was tightened, and the gap between the analog of implant and the framework was measured with a stereomicroscope. The groups' measurements (80 gap values) were analyzed using software (LeicaQWin - Leica Imaging Systems Ltd.) that received the images of a video camera coupled to a Leica stereomicroscope at 100× magnification. The results were statistically analyzed with Kruskal-Wallis One Way ANOVA on Ranks test followed by Dunn's Method, 0.05. Results: The mean values of abutment/framework interface gaps were: Master Cast = 32 μm (SD 2); Group I = 45 μm (SD 3); Group T = 78 μm (SD 25); Group S = 134 μm (SD 30); Group MS = 143 μm (SD 27). No significant difference was detected among Index and Master Cast (P = .05). Conclusion: Under the limitations of this study, it could be suggested that a more accurate working cast is possible using tapered impression copings techniques and stone index. © 2013 Japan Prosthodontic Society.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The accuracy of impressions that transfer the relationship of the implant to the metal framework of the prosthesis continues to be a problem. This study was designed to evaluate the accuracy of the transfer process under variable conditions with regard to implant analog angulations, impression materials, and techniques. Replicas (n = 60) of a metal matrix (control) containing four implants at 90°, 80°, 75°, and 65° in relation to the horizontal surface were obtained by using three impression techniques: T1 - indirect technique with conical copings in closed trays; T2 - direct technique with square copings in open trays; and T3 - square copings splinted with autopolymerizing acrylic resin; and four elastomers: P-polysulfide; I-polyether; A-addition silicone; and Z-condensation silicone. The values of the implant analog annulations were assessed by a profilometer to the nearest 0.017°, then submitted to analysis of variance for comparisons at significance of 5% (P < .05). For implant analog at 90°, the material A associated with T2 and material Z with T3 behaved differently (P < .05) from all groups. At 80°, all materials behaved differently (P < .01) with T1. At 75°, when T1 was associated, materials P and A showed similar behavior, as well as materials I and Z; however, P and A were different from I and Z (P < .01). When T3 was associated, all experimental groups behaved differently among them (P < .01). At 65°, the materials P and Z behaved differently (P < .01) from the control group with T1, T2, and T3; the materials I and A behaved differently from the control group (P < .01) when T1 and T2, respectively, were associated. The more perpendicular the implant analog annulation is in relation to the horizontal surface, the more accurate the impression. The best materials were material I and A and the most satisfactory technique was technique 3.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The Combination Syndrome represents an important pathologic condition of the masticatory system that requires a complex rehabilitation treatment. The presence of flaccid mucosa is one of the most common features due to bone resorption of the pre-maxilla caused by anterior hyperfunction of the mandibular teeth on the maxillary complete denture, where the impact of oclusal loading in this region results in movement of the maxillary prosthesis into the ridge, resulting in increased resorption of the residual ridge, internal misfit and loss of the retention of the maxillary complete denture. The presence of flaccid mucosa, in such cases, leads to problems of support and stability of the maxillary complete denture, which can be treated by surgical reduction of the thickness of the tissue or using specific techniques of fabrication of prostheses. This article describes the oral rehabilitation of a patient with the Combination Syndrome where the surgical reduction of flaccid mucosa was not performed, using a modified technique of functional impression in two steps, with the objective of generating forces and less distortion in flaccid mucosa during functional impression.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The present study aims at evaluating dimensional alteration of stone casts made from impressions with a standard irreversible hydrocolloid and an antimicrobial one. For this, an alginate without disinfectant (Type II Jeltrate) and other containing chlorhexidine (Type II Avagel) were used, which rose by the same regime of treatment: without disinfection; immersion; and spraying. A 1% sodium hypochlorite solution was used for 10 minutes. To obtain the impressions, a perforated impression tray was made from a standard metal model. After molding, the molds were washed in running water for 30 seconds to simulate removal of saliva. Then, with the exception of the control group, these molds were subjected to disinfection treatment. After 10 minutes they were washed again. 60 samples poured with type V special gypsum (Durone) were obtained, that were measured 3 times in a stereomicroscope (SZX12, Olympus) to record the average of dimensional alterations. The disinfection treatment did not bring significant changes in the models obtained from both alginate tested (standard p = 0.7102; with chlorhexidine p = 0.5832). The results showed a statistically significant and additional advantage of the traditional alginate on alginate with chlorhexidine, with respect to dimensional alteration (p < 0.05).

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The dental trade has offered dental impression and dental stone for orthodontic use ensuring accurate models. The compatibility between these materials is defined by the wetting of the model surfaces by the mixture water/stone poured over it and the influenced by the method of disinfection of model and disinfectant solution used. It was evaluated the influence of spray disinfection with sodium hypochlorite 1% on the wettability of two commercial alginate (Jeltrate ® - Dentsply and Orthoprint ® - Zhermack) at two commercial type III gypsum (Rio ® - ME and AOBussoli Orthogesso Orthogesso ®-SA). Twenty models were fabricated for each type of alginate, which were divided into two groups (water and sodium hypochlorite), receiving respectively water and sodium hypochlorite 1% spray. Each group of models was then further divided into two subgroups, and on their surface were poured 2 ml of type III gypsum (Gesso Rio® or Orthogesso®). Reached the final setting of the gypsum specimens were sectioned vertically and medially, settled water with sandpaper No. 400 and mounted on suitable device for reading (in the right and left) of the contact angle Carl Zeiss microscope (precision, 001). The results were submitted to ANOVA and founded statistical significance for solutions used. It was concluded that sodium hypochlorite spray improved wettability of alginates studied.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The cares at the manipulation of the alginate (condensation, disinfection of the impression and the time elapsed until the leak of the plaster) deserve special attention considering the great amount of distortions occurring every time the impression is not fill of plaster in a brief space of time and appropriate storage conditions. Besides its adaptation to the plaster suffers influence of the events happened after the impression is removed of the mouth. The purpose of this research was to evaluate the wetting capacity of three brands of alginate (Jeltrate™,Hydrogum™ e Orthoprint™) by the plaster type III (Rio™) under the influence of disinfection by sodium hypochlorite 1% sprays and the time of storage of 15 minutes,30 minutes, 1 hour, 6, 12 and 24 hours. There were made 60 impressions of each brand of alginate divided in two groups (water and sodium hypochlorite 1%) rearranged after the application of the sodium hypochlorite spray according to the storage time (15 or 30 minutes and 1,6,12, or 24 hours). On the surface of the impressions 2ml of plaster were flowed, proportioned and condensed in agreement with manufacturer‘s instructions. After the final setting expansion the casts were sectioned vertically and medially, regularized at the cut surface (emery paper 400) and setted for reading the contact angle at the microscope Carl Zeiss. The obtained results, submitted to statistical treatment (ANOVA) revealed significant differences when compared the employed solutions (water and sodium hypochlorite 1%) and the time of storage. The sodium hypochlorite 1% exhibited the smallest contact angles and the times of storage of 15 minutes and 6 hours the smallest and larger angles, respectively. It can be concluded that the alginate impressions exhibited larger adaptation to the plaster when disinfected by hypochlorite of sodium 1% and stocked by 15 minutes.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The anatomical and functional impressions philosophies are presented to the professionals who are active in the area, so that they can review concepts and thus obtain more precise molds, based on scientific knowledge. In parallel, impression techniques recommended by the Prosthodontics subject from Araçatuba Dental School – UNESP are also commented.