13 resultados para Dayly routine

em Repositório Institucional UNESP - Universidade Estadual Paulista "Julio de Mesquita Filho"


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Despite the existence of highly sensitive tests, inconclusive serological results are frequent in chronic chagasic infection. This study aimed to define a diagnostic conduct for 30 individuals with inconclusive serology (G3) for chagasic infection assisted at the Outpatient Unit for Infectious and Parasitic Diseases of the Botucatu School of Medicine. Twenty-one individuals with negative serology (G1) and 33 with positive serology (G2) were also studied. Serological methods ELISA, HAI, IFI and immunoblotting TESA-cruzi were used for G1, G2 and G3, and parasitological methods xenodiagnosis, hemoculture and PCR-LIT were used for G2 and G3 individuals. ELISA, HAI and IFI were performed in 5 different blood samples in G2 and G3. TESA-cruzi was carried out only once in G1, G2 and G3 and, since it is the most sensitive, it was utilized as standard. In G3, positivity for ELISA reached 86% in the fifth blood sample; the ELISA+HAI+IFI combination showed a maximum of 44.8% in the second sample; and TESA-cruzi, 76% in one single sample. Xenodiagnosis positivity was 9.4%; hemoculture showed 15.2%; and PCR-LIT exhibited 22% positivity in G2. Nevertheless, in G3, positivity percentage was 3.4% for xenodiagnosis, 6.7% for PCR-LIT, and no positive result was found for hemoculture. In G3, PCR-LIT resolved one case which was still inconclusive according to serology tests. In order to define inconclusive diagnoses, the results suggest the combined use of ELISA+HAI+IFI in 2 blood samples, decreasing the occurrence of false positive/negative results. If results remain inconclusive, the performance of TESA-cruzi and PCR-LIT, if necessary, is recommended.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The identification of appropriate laboratory measures to confirm clinical hypotheses is important in routine paracoccidioidomycosis medical care. The clinical records and laboratory reports of 401 paracoccidioidomycosis patients attended at the Tropical Diseases Area, Faculdade de Medicina de Botucatu, from 1974 to 2008 were reviewed. Direct mycological (DM), cell block (CB), histopathological (HP), and double immunodiffusion (DID) tests were evaluated before treatment. Typical Paracoccidioides brasiliensis yeast forms were observed in clinical specimens of 86% of the patients, but 14% were detected only by serological test. DM of 51 different tissue specimens produced 74.5% sensitivity, and 62.5% sensitivity was observed in 112 sputum samples. CB in 483 sputum samples generated 55.3% sensitivity. HP performed in 239 samples from different tissues revealed 96.7% sensitivity. Serology carried out in 351 patients and 200 healthy controls provided 90.0% sensitivity, 100.0% specificity, 100.0% positive predictive value, 85.1% negative predictive value and 93.6% accuracy. Comparisons of laboratory measurements performed in the same patient showed that sensitivity decreases from HP to DID to CB and DM, with the last two assays providing similar sensitivities. This study demonstrated that P. brasiliensis identification by HP, CB, and/or DM associated with DID is sufficient to establish the laboratorial diagnosis of paracoccidioidomycosis in practically all cases. (C) 2011 Royal Society of Tropical Medicine and Hygiene. Published by Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A simple, rapid, and sensitive spectrophotometric method for routine analysis of saccharin in commercial noncaloric sweeteners is proposed. This method is based on the reaction of saccharin with tetrachloro-p-benzoquinone (p-chloranil) accelerated by hydrogen peroxide and conducted in an ethanol:acetone (4:1) medium, producing a violet-red compound (γ max = 550 nm). Beer's law is obeyed in a concentration range of 2.05 × 10 -4 to 3.00 × 10 -3 M with an excellent correlation coefficient (r = 0.9998). The detection limit was 1.55 × 10 -5 M, and the effect of interferences on the spectrophotometric measurements was evaluated. The proposed procedure was applied successfully to the determination of saccharin in noncaloric sweeteners. Recoveries were within 99.2-104.3% with standard deviations ranging from to 0.5-1.6%. Results of the proposed method compare very favorably with those given by the high-performance liquid chromatography method recommended by the Food and Drug Administration.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The results obtained through biological research usually need to be analyzed using computational tools, since manual analysis becomes unfeasible due to the complexity and size of these results. For instance, the study of quasispecies frequently demands the analysis of several, very lengthy sequences of nucleotides and amino acids. Therefore, bioinformatics tools for the study of quasispecies are constantly being developed due to different problems found by biologists. In the present study, we address the development of a software tool for the evaluation of population diversity in quasispecies. Special attention is paid to the localization of genome regions prone to changes, as well as of possible hot spots.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This research proposes to apply techniques of Mathematics Morphology to extract highways in digital images of high resolution, targeting the upgrade of cartographic products. Remote Sensing data and Mathematical Morphological techniques were integrated in the process of extraction. Mathematical Morphology's objective is to improve and extract the relevant information of the visual image. In order to test the proposed approach some morphological operators related to preprocess, were applied to the original images. Routines were implemented in the MATLAB environment. Results indicated good performances by the implemented operators. The integration of the technologies aimed to implement the semiautomatic extraction of highways with the purpose to use them in processes of cartographic updating.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Modal analysis is widely approached in the classic theory of power systems modelling. This technique is also applied to model multiconductor transmission lines and their self and mutual electrical parameters. However, this methodology has some particularities and inaccuracies for specific applications, which are not clearly described in the technical literature. This study provides a brief review on modal decoupling applied in transmission line digital models and thereafter a novel and simplified computational routine is proposed to overcome the possible errors embedded by the modal decoupling in the simulation/ modelling computational algorithm. © The Institution of Engineering and Technology 2013.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective. The myeloid-related proteins 8 and 14 (MRP-8/MRP-14) and neutrophil-derived S100A12 are biomarkers of inflammation. They can be used to determine the relapse risk in patients with juvenile idiopathic arthritis (JIA) after stopping antiinflammatory treatment. In this study, we tested the performance of different enzyme-linked immunosorbent assays (ELISAs) in order to validate systems available for routine use.Methods. MRP-8/MRP-14 and S100A12 serum concentrations of 188 JIA patients in remission were analyzed. Commercially available test systems were compared to experimental ELISAs established in house. The ability of the assays to identify JIA patients at risk for relapse was analyzed.Results. For MRP-8/MRP-14, the PhiCal Calprotectin and Buhlmann MRP8/14 Calprotectin ELISAs revealed hazard ratios of 2.3 and 2.1, respectively. For S100A12, the CircuLex S100A12/EN-RAGE ELISA revealed a hazard ratio of 3.1. The commercial assays allowed a JIA relapse prediction that was at least comparable to the experimental ELISAs.Conclusion. For the prediction of JIA relapse after stopping medication, the biomarkers MRP-8/MRP-14 and S100A12 can be determined by using assays that are available for routine use. The tested commercial MRP-8/MRP-14 and S100A12 ELISAs showed a performance comparable to well-established experimental ELISA protocols when assay-specific cutoffs for the indication of relapse prediction are thoroughly applied.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Glomerulitis and peritubular capillaritis have been recognized as important lesions in acute renal rejection (AR). We studied glomerulitis and peritubular capillaritis in AR by 2 methods and investigated associations with C4d, type/grade of AR, and allograft survival time. Glomerulitis was measured according to Banff scores (glomerulitis by Banff Method [gBM]) and by counting the number of intraglomerular inflammatory cells (glomerulitis by Quantitative Method [gQM]). Capillaritis was classified by the Banff scoring system (peritubular capillaritis by Banff Method [ptcBM]) and by counting the number of cells in peritubular capillaries in 10 high-power fields (hpf; peritubular capillaritis by Quantitative Method [ptcQM]). These quantitative analyses were performed in an attempt to improve our understanding of the role played by glomerulitis and capillaritis in AR. The g0 + g1 group (gBM) associated with negative C4d (P = .02). In peritubular capillaritis, a larger number of cells per 10 hpf in peritubular capillaries (ptcQM) were observed in positive C4d cases (P = .03). The group g2 + g3 (gBM) correlated with graft loss (P = .01). Peritubular capillaritis was not significantly related to graft survival time. Our study showed that the Banff scoring system is the best method to study glomerulitis and observed that the evaluation of capillaritis in routine biopsies is difficult and additional studies are required for a better understanding of its meaning in AR biopsy specimens of renal allografts.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Some changes in the application of the numeric trapezoidal integration are analyzed for applications considering pi circuits. It is considered numeric and computational proceedings for improving the numeric results obtained with associations of pi circuits. In numeric integration solutions of the linear systems, it is common to represent these associations of pi circuits by only one matrix. This representation introduces undesirable numeric oscillations in simulations of the dynamics of wave propagation in electrical systems. The proposed changes improve the results of application of cascades of pi circuits associated to the trapezoidal integration, avoiding that the numerical oscillations, or Gibb's oscillations, have high values and are slowly damped. For the carried out simulations, different number of pi circuits and voltage sources are checked, confirming the reduction of the influence of the numeric oscillations on the obtained results. (C) 2014 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper describes the importance of an innovative analytical technique for drugs and pharmaceuticals quantification, using Fouriertransform infrared (FTIR) transmission spectroscopy. This method does not use organic solvents, which is one great advantage over the most common analytical methods. This fact contributes to minimize the generation of organic solvent waste by the industry and thereby reduces the impact of its activities on the environment. The method involved absorbance measurements of the band corresponding to one of the chosen group in the molecule. Obviously, the method should be validated according to ICH guidelines, showing linearity, precision, accuracy and robustness, over a concentration range, using small amounts to prepare the analyte. The validated method is able to quantify drugs and pharmaceuticals and can be used as an environmentally friendly alternative for the routine analysis in pharmaceutical industry quality control.