28 resultados para Cyanoacrylate
em Repositório Institucional UNESP - Universidade Estadual Paulista "Julio de Mesquita Filho"
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
The aim of this study was to evaluate the tensile strength of orthodontic wires bonded onto the enamel with cyanoacrylate ester. To obtain the specimens, 120 human premolars (extracted for orthodontic or periodontal reasons) were included in acrylic blocks of rapid polymerization with three teeth each. Four groups were formed with ten specimens each. In the specimens, a dental splint model was made with cyanoacrylate ester and round stainless steel wire. In groups I, II and III, cyanoacrylate ester was used with round steel wires, with variation in diameter: 0.014 inches; 0.016 inches and 0.018 inches, respectively. In group IV, round steel wire 0.018 inches was used with photo polymerizing resin composite with previous acid etching. The adhesive force of the materials was measured in two points under the action of the tensiometer (ETM-USA). The number of loose wires was counted along with those that remained fixed according to the different levels of force applied because of the direction of the tensile force (vertical or horizontal) and the diameter of the wire used. The data obtained were first submitted to a descriptive analysis and then submitted to a statistical analysis (Friedman's Test and Dunn's Test of Multiple Comparison - Epi-info 3.2). Within the limitations of the experimental conditions presented, the cyanoacrylate ester or 'Super Bonder (R)' maintained bonded to enamel and steel wires (0.016 and 0.018 inches) during the tensile strength tests under different levels of applied forces.
Resumo:
This paper reports a case of tooth replantation in which the splinting was performed with stainless steel orthodontic wire and a widely marketed brand of quick-setting cyanoacrylate ester adhesive (Super Bonder((R))). The long-term clinical and radiographic success of the case reported in this paper indicates that the splinting technique using a quick-setting cyanoacrylate ester adhesive may be a feasible option for making a rapid, simple and efficient contention of replanted teeth in situations where the routinely used materials are not readily available.
Resumo:
Objective: The purpose of this study was to perform histological and histometric analyses of the repair process of autogenous bone grafts fixed at rat calvaria with ethyl-cyanoacrylate adhesive. Material and Methods: Thirty-two rats were divided into two groups (n=16), Group I - Control and Group II - Adhesive. Osteotomies were made at the right parietal bone for graft obtainment using a 4-mm-diameter trephine drill. Then, the bone segments were fixed with the adhesive in the parietal region of the opposite side to the donor site. After 10 and 30 days, 8 animals of each group were euthanized and the calvarias were laboratorially processed for obtaining hematoxylin and eosin-stained slides for histological and histometric analyses. Results: An intense inflammatory reaction was observed at the 10-day period. At 30 days, this reaction was less intense, despite the presence of adhesive at the recipient-site/graft interface. Graft incorporation to the recipient site was observed only at the control group, which maintained the highest graft size at 10 and 30 days. Conclusions: Although the fragment was stable, the presence of adhesive in Group II did not allow graft incorporation to the recipient site, determining a localized, discrete and persistent inflammatory reaction.
Resumo:
This study compared the fixation of autogenous onlay bone grafts with cyanoacrylate glue (Super Bonder) and with titanium screws. Twenty rabbits underwent bilateral parietal ostectomies. Bone segments were fixed anteriorly to the resulting bone defect. In group I, the grafts were fixed with 4 min long, 1.5 mm diameter screws; in group II, adhesive was used. The animals were killed after 5, 15, 30, 60 and 120 days. Histomorphometric analysis was used to quantify the maintenance of the graft area. Discrete areas of inflammatory reaction were seen in both groups after 5 days and for group II after 15 days. After 30 days, new bone formation was seen at the interface of the grafts. After 120 days, the graft was incorporated into the host bed in group I and partially incorporated in group II. There was a significant statistical difference regarding the mean graft areas between 15 and 120 days (p < 0.001) and between fixation methods (p < 0.002). Fixation with adhesive promoted a significantly greater area of bone graft than screw fixation, independent of time period. The adhesive was biocompatible, presented similar stability to the screw and maintained the bone area, although there was a delay in graft incorporation.
Resumo:
Background Tissue adhesives have been widely used for wound closure, especially in children, because they are painless, fast, and easy to use and result in minimal scarring.Objective To analyze the biocompatibility of an adhesive based on n-butyl-cyanoacrylate in the subcutaneous tissue of rats.Materials and Methods Two surgical sites were prepared (approximately 3 cm apart): one on the left side of the animal and the other on the right side); polyethylene tubes were implanted in each surgical site. The tube on the left was filled with n-butyl-cyanoacrylate (treated group) and the tube on the right side was unfilled (control group). After 7, 30, and 120 days, the animals were killed, and the specimens were processed for histologic analysis.Results No significant inflammatory reaction occurred in the treated group, showing results similar to the control group.Conclusion This adhesive based on n-butyl-cyanoacrylate is biocompatible in the subcutaneous tissue of rats.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
The present study analyzes the repair process of autogenous bone graft in a block fixed with ethyl cyanoacrylate and 2-octyl cyanoacrylate adhesives in rat calvaria. Forty-eight rats, divided into 3 groups, received round osteotomies at the right parietal bone for the attainment of autogenous bone graft fragment, which was fixed at the opposite side to the donor site with ethyl cyanoacrylate (ethyl group) and 2-octyl cyanoacrylate (octyl group) adhesives. In the control group, bone fragment was only juxtaposed at the parietal bone surface without any fixation material. The animals were euthanized after 10 and 60 postoperative days. The calvariae were processed in a laboratory for the attainment of slides stained through the hematoxylin and eosin technique for histological and histometric analysis. The qualitative analysis showed a discrete inflammatory infiltrate in the control group and moderate inflammatory infiltrate in the ethyl and octyl groups at the 10-day period, which remained at the 60-day period, mainly in the octyl group. The bone fragment remained bonded to the recipient site through the adhesive, but graft incorporation was not observed in any of the specimens. Resorption was higher in the octyl group followed by the ethyl and control groups, both at the 10-and 60-day periods, but with no statistical significance (P < .05). Although promoting graft fixation and its maintenance at the recipient site, both studied adhesives did not allow the graft incorporation, producing a localized and discrete inflammatory reaction, which persisted at 60 days, being more intense in the octyl cyanoacrylate group.
Resumo:
Em eqüinos, as enterotomias no cólon descendente são necessárias para remover enterólitos, corpos estranhos e material alimentar compactado que não podem ser removidos por técnicas conservativas. Este segmento intestinal possui um suprimento sangüíneo pobre, além de predisposição a complicações pós-operatórias relacionadas à contaminação bacteriana. Assim, este estudo foi conduzido com o objetivo de efetuar avaliações clínicas e anatomopatológicas do emprego de adesivo tecidual à base de cianoacrilato no cólon descendente de eqüinos, comparando-o a uma técnica de sutura aposicional convencional. A intervenção cirúrgica foi realizada em 15 animais posicionados em decúbito lateral direito, através de laparotomia pelo flanco esquerdo, sob anestesia geral inalatória. Após a exteriorização do cólon descendente, foram realizadas duas enterotomias de cinco centímetros de extensão cada, distanciadas 20cm uma da outra. Os animais foram aleatoriamente distribuídos em cinco tempos de observação de três animais cada e sacrificados aos três, sete, 14, 35 e 70 dias de pós-operatório. O adesivo butil-2-cianoacrilato e o fio de poliglactina 910 mostraram-se igualmente apropriados para uso em enterorrafias desse órgão, sendo que o fio de poliglactina 910 provocou inflamação inicial mais intensa que o cianoacrilato e, mais tardiamente, ambos causaram inflamação granulomatosa do tipo corpo estranho observada, primeiramente, junto ao fio de poliglactina 910 (7º dia) e, a partir do 35º dia, ao redor do cianoacrilato.
Resumo:
OBJETIVO: Avaliar a ligação entre músculos oculares extrínsecos e esferas de polietileno poroso usando um bioadesivo. MÉTODOS: Estudo experimental envolvendo 8 coelhos albinos submetidos a enucleação do olho direto com colocação de implante esférico de polietileno poroso de 12 mm de diâmetro unido aos músculos oculares extrínsecos por meio do bioadesivo 2-octil-cianoacrilato. Noventa dias após a cirurgia os animais foram sacrificados e o conteúdo orbitário removido. em 4 animais foi realizado estudo biomecânico, avaliando-se a força de ruptura entre a musculatura e a esfera (grupo implante) e entre a musculatura e a esclera nos olhos contralaterais (grupo controle). Nos outros 4 animais foi realizada análise histológica. RESULTADO: A avaliação biomecânica revelou que a força de ruptura entre esfera-músculo e esclera-músculo foram semelhantes quando se usa o adesivo de cianoacrilato. O exame histológico mostrou reação fibrovascular no local da adesão entre a musculatura e a esfera, sem efeitos deletérios aos tecidos. Ao redor dos implantes foi possível observar pseudocápsula e no interior, neovasos e tecido fibrovascular preenchendo os espaços entre os grânulos do polietileno. CONCLUSÃO: O adesivo 2-octil-cianoacrilato mantém boa força de adesão na união entre os músculos e as esferas de polietileno poroso, com redução do tempo cirúrgico e sem efeitos deletérios aos tecidos orbitais. Desta forma, deve-se considerar o uso do bioadesivo na reconstrução da cavidade anoftálmica.
Resumo:
FUNDAMENTOS - Adesivos teciduais têm sido muito usados para síntese de ferida, em função de ser um método indolor, rápido e de fácil execução. OBJETIVOS -Analisar e comparar compatibilidade dos adesivos, etil- cianoacrilato (Super Bonder) e butilcianoacrilato (Histoacryl), e a reparação de incisões em dorso de ratos entre o fio de sutura e os respectivos adesivos. MÉTODOS - Foram usados 15 ratos. Realizaram-se duas lojas cirúrgicas no dorso. em cada uma, foi implantado um tubo de polietileno (10mm x 1mm), os quais foram preenchidos com os adesivos Super Bonder (lado direito) e Histoacryl (lado esquerdo). As incisões, do lado esquerdo, foram coaptadas com Super Bonder, e as do lado direito, com Histoacryl. Uma incisão mediana, entre as duas incisões,foi realizada e suturada com fio de seda. Os animais foram mortos, depois de 7(sete), 35(trinta) e 120 (cento e vinte dia) dias. RESULTADOS: Os adesivos usados, no presente estudo, não promoveram reação inflamatória, quando usados para síntese das incisões. Porém, estes adesivos, quando implantados no subcutâneo, promoveram reação inflamatória até 120 (cento e vinte dia) dias, no entanto, a reação é mais intensa com Histoacryl. CONCLUSÕES: Super Bonder e Histoacryl permitem o processo cicatricial dos tecidos incisados; facilitam a sutura das incisões. Desta forma, estes podem ser utilizados para sínteses de feridas, lacerações ou incisões cutâneas.
Resumo:
Purpose: This study tested the hypothesis that the tribochemical silica coating on ceramic surfaces increases the bond strength of resin cement to a glass-infiltrated zirconium-based ceramic. Materials and Methods: Fifteen blocks of In-Ceram Zirconia from CEREC InLab (5 per group) and 15 composite blocks (Z-250) 5 mm x 5 mm x 4 mm were made. The ceramic surfaces were polished, and the blocks were divided into three groups: (1) airborne abrasion with 110-μm aluminum oxide particles; (2) Rocatec system, tribochemical silica coating; and (3) CoJet system, tribochemical silica coating. The ceramic blocks were cemented to the composite blocks using Panavia F according to the manufacturer's specifications. All samples were stored in 37°C distilled water for 7 days and later sectioned in two axes using a diamond disk under cooling to obtain specimens with a cross-sectional area of approximately 1 mm2 (n = 45). Each specimen was then attached with cyanoacrylate glue to an adapted device for the microtensile test, which was carried out on a universal testing machine. Results: The results were subjected to ANOVA and Tukey's test. Group 2 (23.0 ± 6.7 MPa) and group 3 (26.8 ± 7.4 MPa) showed greater bond strength than group 1 (15.1 ± 5.3 MPa). There was no significant difference between groups 2 and 3. All failures were in the adhesive zone. Conclusion: The hypothesis was confirmed - the tribochemical systems increased the bond strength between Panavia F and In-Ceram Zirconia.