5 resultados para Contact Resistance

em Repositório Institucional UNESP - Universidade Estadual Paulista "Julio de Mesquita Filho"


Relevância:

60.00% 60.00%

Publicador:

Resumo:

This work introduces the results from the performing of impedance spectroscopy on the transition metals oxide Ca1.2La0.8FeIrO6. It was sought to understand the behavior of one sample from its impedance spectra for different AC voltages and temperature values and if an applied external magnetic field at room temperature would cause some change on it. The results revealed that the Ca1.2La0.8FeIrO6 at high temperatures shows conductive and inductive behavior and that the resistance increases with frequency, phenomenon known as Kelvin effect. At 150 K, the spectrum real part no longer consists with the theoretical prediction of Kelvin effect, starting to be influenced by the utilized voltages, condition that inexists on theory. At low temperatures (10, 20, 30 K) it was observed resistive and capacitive behavior, being possible on these conditions, associate to the sample a paralel RC circuit in series with a contact resistance with a fitting from the ZSim software. This fitting allowed the obtaining of capacitance, DC resistance and contact resistance values. The application of a 700G magnetic field at room temperature didn't cause changes on the spectra

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper describes a technique for extending the force range of thin conductive polymer force sensors used for measuring contact force. These sensors are conventionally used for measuring force by changing electrical resistance when they are compressed. The new method involves measuring change in electrical resistance when the flexible sensor, which is sensitive to both compression and bending, is sandwiched between two layers of spring steel, and the structure is supported on a thin metal ring. When external force is applied, the stiffened sensor inside the spring steel is deformed within the annular center of the ring, causing the sensor to bend in proportion to the applied force. This method effectively increases the usable force range, while adding little in the way of thickness and weight. Average error for loads between 10 N and 100 N was 2.2 N (SD = 1.7) for a conventional conductive polymer sensor, and 0.9 N (SD = 0.4) using the new approach. Although this method permits measurement of greater loads with an error less than 1 N, it is limited since the modified sensor is insensitive to loads less than 5 N. These modified sensors are nevertheless useful for directly measuring normal force applied against handles and tools and other situations involving forceful manual work activities, such as grasp, push, pull, or press that could not otherwise be measured in actual work situations.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

When the carious tissue is eliminated either by conventional methods (with burs) or with lasers, the risk of accidentally damage the surface of adjacent teeth may occur, which hypothetically could lead to a more susceptible surface for canes formation. This in vitro study aims to evaluate the caries resistance of the dental enamel surface irradiated by the Nd:YAG laser applied in conditions simulating accidental exposition. Thirteen third molars were used in this study. The experimental groups were: G1: sound control and control + carious; G2: contact Nd:YAG laser at 0.75, 1, 2, or 3 W; 10 Hz; 3 sec (27, 35, 71, and 106 J/cm(2)); G3: same parameters from G2 + caries artificial induction through the demineralization and demineralization (DES/RE) dynamic model. The caries resistance analysis was evaluated by the superficial morphological aspect through SEM images and also by Ca/P proportion through energy dispersive X-ray spectroscopy (EDX). The micrograph images showed that the Nd:YAG laser changed the normalmorphology of the enamel prisms resulting in a melted and re-solidified surface intensified with the power increase. Significant statistical differences were observed applying the Kruskal-Wallis statistical test (p <= 0.01) among the Nd:YAG laser irradiated groups and the control with caries regarding the Ca/P proportion. As an exception, this was not observed when 3 W; 10 Hz; 3 sec; 106 J/cm(2) was applied and posteriously submitted to a cariogenic challenge. The results indicate that the Nd:YAG laser accidental irradiation at low power settings did not represent risks to the enamel caries resistance.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Comparative studies between brown dog tick Rhipicephalus sanguineus populations from Brazil (Jaboticabal, São Paulo) and Argentina (Rafaela, Santa Fé) showed significant biological, morphological and genetic differences between them. This work aimed to study, in a comparative way, the acquisition of resistance in domestic dogs to R. sanguineus from Jaboticabal and Rafaela, after successive and controlled infestations. Ticks were kept in a BOD incubator under controlled conditions (27 °C, 80 % relative humidity, 12-h photoperiod). Ten dogs, Dachshund breed, males and females, 6 months old, short- or long-haired, without prior contact with ticks, were used as hosts. They were distributed into two experimental groups composed of five animals each: G1 infested with ten adult couples of R. sanguineus (Jaboticabal) per animal, and G2 infested with ten adult couples of R. sanguineus (Rafaela) per animal. Ticks' biological parameters and titration of antibodies from the dogs' sera by ELISA test were used for comparison between the strains. Results of the biological parameters showed that the dogs did not acquire immunity to either of the R. sanguineus strains after repeated infestations. The ELISA test showed low antibody titers in sera of dogs from G2, in successive infestations, and higher antibody responses post second and third infestations in G1. It also demonstrated cross-reactivity between sera of dogs infested with R. sanguineus (Jaboticabal) and antigens from R. sanguineus (Rafaela) and vice versa. We conclude that Dachshund dogs did not develop resistance against neither Jaboticabal nor Rafaela strains of R. sanguineus.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The purpose of this work is the deposition of films in order to increase the corrosion resistance of AISI 304 steel, which is a material used to construct the reactors for bioethanol production. This deposition inhibits the permeation of corrosive species to the film-metal interface. Thin films were prepared by radio-frequency plasma enhanced chemical vapor deposition (RF-PECVD) method using plasmas of hexamethyldisiloxane/argon/oxygen mixtures excited by signals of different powers. The plasma was generated by the application of RF power of 13.56 MHz to the sample holder while keeping grounded the topmost electrode and the chamber walls. The effect of the RF power on the properties of the samples was investigated by perfilometry, X-ray photoelectron spectroscopy (XPS), contact angle, and electrochemical impedance spectroscopy (EIS). The results of the corrosion resistance tests of the AISI 304 steel were interpreted in terms of the energy delivered to the growing layer by plasma excitation power.