26 resultados para Construcciones de adobe

em Repositório Institucional UNESP - Universidade Estadual Paulista "Julio de Mesquita Filho"


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of this study was to describe a new technique by using Adobe Photoshop CS (San Jose, CA) image-analysis software to evaluate the radiographic changes of chronic periapical lesions after root canal treatment by digital subtraction radiography. Thirteen upper anterior human teeth with pulp necrosis and radiographic image of chronic periapical lesion were endodontically treated and radiographed 0, 2, 4, and 6 months after root canal treatment by using a film holder. The radiographic films were automatically developed and digitized. The radiographic images taken 0, 2, 4, and 6 months after root canal therapy were submitted to digital subtraction in pairs (0 and 2 months, 2 and 4 months, and 4 and 6 months) choosing image, calculation, subtract, and new document tools from Adobe Photoshop CS image-analysis software toolbar. The resulting images showed areas of periapical healing in all cases. According to this methodology, the healing or expansion of periapical lesions can be evaluated by means of digital subtraction radiography by using Adobe Photoshop CS software.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Few quantitative data exist on pupil diameter, particularly in children. In this article we describe an analysis of pupil diameter and pupil area in normal preschool children during attentive gaze (AG) and spontaneous gaze (SG) using digital imaging. The pupil diameter and pupil area of 200 preschool children aged 4 to 6 years were evaluated. The images were recorded with a digital camera, transferred to a computer, processed by movie software and submitted to the Invert filter of Adobe Photoshop (R) software. Three consecutive measures of pupil diameter and pupil area were taken for both eyes during AG and SG. Arithmetic means of each parameter were calculated and data were expressed in millimeters. Mean pupil diameter was similar for both eyes, presenting values of 4.9 mm during AG and 4.1 mm during SG. Mean pupil area was also similar for both eyes, presenting values of 15.6 mm(2) and 9.1 mm(2) during AG and SG, respectively. There were no differences between boys and girls. However, 6-year-old children showed lower pupil diameter and area under both evaluation conditions.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of this study was to analyze the color alterations performed by the CIE L*a*b* system in the digital imaging of shade guide tabs, which were obtained photographically according to the automatic and manual modes. This study also sought to examine the observers' agreement in quantifying the coordinates. Four Vita Lumin Vaccum shade guide tabs were used: A3.5, B1, B3 and C4. An EOS Canon digital camera was used to record the digital images of the shade tabs, and the images were processed using Adobe Photoshop software. A total of 80 observations (five replicates of each shade according to two observers in two modes, specifically, automatic and manual) were obtained, leading to color values of L*, a* and b*. The color difference (AE) between the modes was calculated and classified as either clinically acceptable or unacceptable. The results indicated that there was agreement between the two observers in obtaining the L*, a* and b* values related to all guides. However, the B1, B3, and C4 shade tabs had AE values classified as clinically acceptable (Delta E = 0.44, Delta E = 2.04 and Delta E = 2.69, respectively). The A3.5 shade tab had a AE value classified as clinically unacceptable (Delta E = 4.17), as it presented higher values for luminosity in the automatic mode (L* = 54.0) than in the manual mode (L* = 50.6). It was concluded that the B1, B3 and C4 shade tabs can be used at any of the modes in digital camera (manual or automatic), which was a different finding from that observed for the A3.5 shade tab.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objectives: The aim of this study was to compare two methods for the evaluation of periapical lesion changes following endodontic therapy (digital subtraction technique and morphometric analysis) by outlining the radiolucent area.Methods: 13 human anterior teeth with pulp necrosis and chronic periapical lesions were used. Periapical radiographs were taken immediately after endodontic therapy (0) and then 2 months, 4 months and 6 months post treatment, using an intraoral radiographic film holder stabilized with impression material. The films were processed in a standard manner and the digitized images were submitted to digital subtraction using Adobe Photoshop 6.0. New bone formation or bone resorption areas were then measured. In the morphometric analysis, the periapical lesions were outlined using VixWin 2000 and the area (in square millimetres) was recorded. The obtained data were submitted to agreement analysis for comparison of the two techniques.Results: There was no correlation between the areas of radiographic changes detected by digital subtraction and periapical lesion outline (r=0.02-0.45). The new bone formation areas observed by digital subtraction presented higher values, with bone changes being especially evident in the 2 month follow-up radiographs, which suggests a higher sensitivity for this method.Conclusions: Both methods are suitable for the evaluation of periapical lesion changes, but the digital subtraction technique is more sensitive for detecting radiographic periapical changes. Dentomaxillofacial Radiology (2009) 38, 438-444. doi: 10.1259/dmfr/53304677

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Novos processos de produção de conteúdo estão reconfigurando os organogramas e os fluxogramas de setores ligados à criação de programas informativos e de entretenimento nas emissoras de televisão. A elaboração de conteúdos centrados em um modo de Comunicação que procura contemplar a participação e a colaboração da audiência nas construções discursivas impõe a existência de estruturas capazes de responder às demandas de uma plataforma multimídia, engendrada por tecnologias que possibilitem a conectividade entre os diversos dispositivos móveis e portáteis. Além de evidenciar os desafios de caráter organizacional, o presente trabalho, baseado em pesquisa bibliográfica e documental, tem como objetivo discutir as implicações estéticas dos conteúdos gerados para o consumo multimídia. Assim, toma como objeto de análise a estrutura e a programação da Televisão Universitária Unesp, da Universidade Estadual Paulista, em fase de implantação no campus de Bauru-SP.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Esta pesquisa é um estudo transversal realizado junto a 2282 estudantes de ambos os sexos que cursavam as três séries do ensino médio em três cidades do interior do oeste paulista. O instrumento de coleta de dados empregado foi um questionário autoaplicável com 131 questões. Neste artigo, abordamos as trajetórias sexuais de adolescentes de ambos os sexos que mantêm práticas sexuais homoeróticas ou não. Discutimos as relações desses adolescentes com seus familiares e grupos de pares e a questão de sair do armário como ferramenta política. Tendo como base as concepções de Sedgwick, analisamos os momentos em que sair do armário pode ser uma entre tantas maneiras de manifestação das diferentes sexualidades em relação à heteronormatividade. Apoiando-nos nas colocações de teóricos pós-estruturalistas, abordamos também as construções teóricas e as produções discursivas sobre a adolescência, apontando novas manifestações da juventude na contemporaneidade. Por fim, percebemos a existência de amplos fatores que afetam as decisões de jovens não heterossexuais quanto a sair (ou não) do armário para além da homofobia: eventos pessoais, histórias de vida e mesmo a revelação de sua sexualidade aos pais e/ou a outras pessoas.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objectives: To compare simulated periodontal bone defect depth measured in digital radiographs with dedicated and non-dedicated software systems and to compare the depth measurements from each program with the measurements in dry mandibles.Methods: Forty periodontal bone defects were created at the proximal area of the first premolar in dry pig mandibles. Measurements of the defects were performed with a periodontal probe in the dry mandible. Periapical digital radiographs of the defects were recorded using the Schick sensor in a standardized exposure setting. All images were read using a Schick dedicated software system (CDR DICOM for Windows v.3.5), and three commonly available non-dedicated software systems (Vix Win 2000 v.1.2; Adobe Photoshop 7.0 and Image Tool 3.0). The defects were measured three times in each image and a consensus was reached among three examiners using the four software systems. The difference between the radiographic measurements was analysed using analysis of variance (ANOVA) and by comparing the measurements from each software system with the dry mandibles measurements using Student's t-test.Results: the mean values of the bone defects measured in the radiographs were 5.07 rum, 5.06 rum, 5.01 mm and 5.11 mm for CDR Digital Image and Communication in Medicine (DICOM) for Windows, Vix Win, Adobe Photoshop, and Image Tool, respectively, and 6.67 mm for the dry mandible. The means of the measurements performed in the four software systems were not significantly different, ANOVA (P = 0.958). A significant underestimation of defect depth was obtained when we compared the mean depths from each software system with the dry mandible measurements (t-test; P congruent to 0.000).Conclusions: the periodontal bone defect measurements in dedicated and in three non-dedicated software systems were not significantly different, but they all underestimated the measurements when compared with the measurements obtained in the dry mandibles.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objectives: the purpose of this study was to evaluate the correlation between central incisor form and face form in 4 racial groups and to investigate if there was agreement among experts in categorizing the central incisor forms. Method and Materials: A total of 160 subjects (40 whites, 40 mulattos, 40 blacks, and 40 Asians) ranging from 18 to 33 years of age were selected. Digital photographic records were made, 1 full-face and 1 intraoral view of the maxillary right central incisor. The outline tracings of the tooth and face images were obtained using Adobe Photoshop 5.0 software. The outline tracings were printed in distinct transparencies, and 3 prosthodontists determined if there was correspondence between the tooth and the face forms by superimposition of the transparencies. If there was disagreement among the prosthodontists' evaluations, the prevalent decision was considered. The experts also classified the central incisor forms into square, ovoid, tapering, or combination at 2 different sessions. At the first session, no instructions were given. At the second session, the prosthodontists were instructed to follow Williams' method of classification. Results: A correspondence between tooth and face forms was found in 23.75% of all cases. Agreement on the tooth form classifications among the prosthodontists occurred in 30.62% of all cases at the first session and 24.37% at the second session. Conclusion: There is not a highly defined correlation between central incisor form and face form in any racial group studied. In addition, the experts were not in fair agreement in categorizing tooth forms.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Since bovine teeth have been used as substitutes for human teeth in in vitro dental studies, the aim of this study was to compare the radiographic density of bovine teeth with that of human teeth to evaluate their usability for radiographic studies. Thirty bovine and twenty human teeth were cut transversally in 1 millimeter-thick slices. The slices were X-rayed using a digital radiographic system and an intraoral X-ray machine at 65 kVp and 7 mA. The exposure time (0.08 s) and the target-sensor distance (40 cm) were standardized for all the radiographs. The radiographic densities of the enamel, coronal dentin and radicular dentin of each slice were obtained separately using the histogram tool of Adobe Photoshop 7.0 software. The mean radiographic densities of the enamel, coronal dentin and radicular dentin were calculated by the arithmetic mean of the slices of each tooth. One-way ANOVA demonstrated statistically significant differences for the densities of bovine and human enamel (p < 0.05) and for bovine and human coronal dentin (p < 0.05). No statistically significant differences were found for the bovine and human radicular dentin (p > 0.05). Based on the results, the authors concluded that: a) the radiographic density of bovine enamel is significantly higher than that of human enamel; b) the radiodensity of bovine coronal dentin is statistically lower than the radiodensity of human coronal dentin; bovine radicular dentin is also less radiodense than human radicular dentin, although this difference was not statistically significant; c) bovine teeth should be used with care in radiographic in vitro studies.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: This study was performed to compare the inverted digital images and film-based images of dry pig mandibles to measure the periodontal bone defect depth. Materials and Methods: Forty 2-wall bone defects were made in the proximal region of the premolar in the dry pig mandibles. The digital and conventional radiographs were taken using a Schick sensor and Kodak F-speed intraoral film. Image manipulation (inversion) was performed using Adobe Photoshop 7.0 software. Four trained examiners made all of the radiographic measurements in millimeters a total of three times from the cementoenamel junction to the most apical extension of the bone loss with both types of images: inverted digital and film. The measurements were also made in dry mandibles using a periodontal probe and digital caliper. The Student's t-test was used to compare the depth measurements obtained from the two types of images and direct visual measurement in the dry mandibles. A significance level of 0.05 for a 95% confidence interval was used for each comparison. Results: There was a significant difference between depth measurements in the inverted digital images and direct visual measurements (p>|t|=0.0039), with means of 6.29 mm (IC95%:6.04-6.54) and 6.79 mm (IC95%:6.45-7.11), respectively. There was a non-significant difference between the film-based radiographs and direct visual measurements (p>|t|=0.4950), with means of 6.64mm (IC95%:6.40-6.89) and 6.79mm(IC95%:6.45-7.11), respectively. Conclusion: The periodontal bone defect measurements in the inverted digital images were inferior to film-based radiographs, underestimating the amount of bone loss. copy; 2012 by Korean Academy of Oral and Maxillofacial Radiology.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective. This study aimed to investigate the stress distribution in screwed implant-supported prostheses with different implant-abutment connections by using a photoelastic analysis. Materials and methods. Four photoelastic models were fabricated in PL-2 resin and divided according to the implant-abutment connection (external hexagon (EH) and Morse taper (MT) implants (3.75 × 11.5 mm)) and the number crowns (single and 3-unit piece). Models were positioned in a circular polariscope and 100-N axial and oblique (45) loading were applied in the occlusal surface of the crowns by using a universal testing machine. The stresses were photographically recorded and qualitatively analyzed using software (Adobe Photoshop). Results. Under axial loading, the MT implants exhibited a lower number of fringes for single-unit crowns than EH implants, whereas for a 3-unit piece the MT implants showed a higher number of fringes vs EH implants. The oblique loading increased the number of fringes for all groups. Conclusion. In conclusion, the MT implant-abutment connection reduced the amount of stress in single-unit crowns, for 3-unit piece crowns the amount of stress was lower using an external hexagon connection. The stress pattern was similar for all groups. Oblique loading promoted a higher stress concentration than axial loading. © Informa Healthcare.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This study aimed to evaluate the influence of irrigation needle gauge and design, and the final root canal diameter on the apical cleaning efficacy. Twelve human mandibular incisors were used. At different stages of root canal widening (sizes 20, 30 and 40 K-files), root canals were filled with radiopaque contrast medium. Four different needles were evaluated: 23G with side opening, 22G with apical opening, 30G with side opening and 30G with apical opening. Irrigation was carried out with 2 mL distilled water. The same tooth was radiographed with a digital system several times to assess the four types of needle in those three stages of canal widening. Pre-irrigation (canals filled with contrast) and post-irrigation (canals with remaining contrast) images were submitted to digital subtraction using the Adobe Photoshop CS4 program. Pre-irrigation (filled with contrast) and subtracted (cleaned by irrigation) areas were outlined by a trained and blinded operator using the Image Tool 3.0 software. Their ratio was calculated to express the percentage of apical cleaning in each stage of canal widening (sizes 20, 30 and 40 K-files) with each of the four needles. Data obtained were subjected to one-way ANOVA and Tukey's tests. The 30G needles with side and apical opening promoted better apical cleaning at all stages of root canal widening (p<0.05). In conclusion, smaller diameter needles were more efficacious in cleaning the apical third of the root canals, regardless of their design.