29 resultados para Constitution of the self

em Repositório Institucional UNESP - Universidade Estadual Paulista "Julio de Mesquita Filho"


Relevância:

100.00% 100.00%

Publicador:

Resumo:

We consider arbitrary U (1) charged matter non-minimally coupled to the self-dual field in d = 2 + 1. The coupling includes a linear and a rather general quadratic term in the self-dual field. By using both Lagragian gauge embedding and master action approaches we derive the dual Maxwell Chern-Simons-type model and show the classical equivalence between the two theories. At the quantum level the master action approach in general requires the addition of an awkward extra term to the Maxwell Chern-Simons-type theory. Only in the case of a linear coupling in the self-dual field can the extra term be dropped and we are able to establish the quantum equivalence of gauge invariant correlation functions in both theories.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective: The goal of this study was to evaluate the efficacy of the Self-Adjusting File (SAF) and ProTaper for removing calcium hydroxide [Ca(OH)2] from root canals. Material And Methods: Thirty-six human mandibular incisors were instrumented with the ProTaper system up to instrument F2 and filled with a Ca(OH)2-based dressing. After 7 days, specimens were distributed in two groups (n=15) according to the method of Ca(OH)2 removal. Group I (SAF) was irrigated with 5 mL of NaOCl and SAF was used for 30 seconds under constant irrigation with 5 mL of NaOCl using the Vatea irrigation device, followed by irrigation with 3 mL of EDTA and 5 mL of NaOCl. Group II (ProTaper) was irrigated with 5 mL of NaOCl, the F2 instrument was used for 30 seconds, followed by irrigation with 5 mL of NaOCl, 3 mL of EDTA, and 5 mL of NaOCl. In 3 teeth Ca(OH)2 was not removed (positive control) and in 3 teeth canals were not filled with Ca(OH)2 (negative control). Teeth were sectioned and prepared for the scanning electron microscopy. The amounts of residual Ca(OH)2 were evaluated in the middle and apical thirds using a 5-score system. Results: None of the techniques completely removed the Ca(OH)2 dressing. No difference was observed between SAF and ProTaper in removing Ca(OH)2 in the middle (P=0.11) and the apical (P=0.23) thirds. Conclusion: The SAF system showed similar efficacy to rotary instrument for removal of Ca(OH)2 from mandibular incisor root canals.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Our conception of education is that it is the responsible action whereby man becomes human, trains and faces the challenges that life and the world present, as man enters a larger, shared cultural tradition and thus joins the world. However such sharing implies that we must not just rely on tradition, but remain open to new ideas. It is essential for schooling to preserve a field where the art of living intersects with the world for which future generations are being prepared. It is in this field of intersection that this essay seeks to discuss Michel Foucault's thought, care of the self and the role played by others in the acquisition of ethical attitudes pertaining to one's conduct in life. Through reconstructing Foucault's ideas, we elaborate on the hypothesis that, before morally shaping students, teaching them values, or aiding in their skill acquisition in the sense prevailing in schooling today, it is important to understand the notion of care of the self (and how the notion implies interaction with others for effective care of the self). Care of the self is vital for thoroughly understanding the relationships between ethics and education in school. We particularly examine how Foucault's ideas and his analysis of the teacher's role in shaping the student's life conduct can help educators rethink pedagogical action in an ethical sense and find within it a certain openness to the formation of attitudes in educators and students

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The objective of this study was to measure the thickness of the hybrid layer (HLT), length of resin tags (RTL) and bond strength (BS) in the same teeth, using a self-etching adhesive system Adper Prompt L Pop to intact dentin and to analyze the correlation between HLTand RTL and their BS. Ten human molars were used for the restorative procedures and each restored tooth was sectioned in mesio-distal direction. One section was submitted to light microscopy analysis of HLT and RTL (400x). Another section was prepared and submitted to the microtensile bond test (0.5 mm/min). The fractured surfaces were analyzed using scanning electron microscopy to determine the failure pattern. Correlation between HLT and RTL with the BS data was analyzed by linear regression. The mean values of HLT, RTL and BS were 3.36 microm, 12.97 microm and 14.10 MPa, respectively. No significant relationship between BS and HLT (R2= 0.011, p>0.05) and between BS and RTL (R2= 0.038) was observed. The results suggested that there was no significant correlation between the HLT and RTL with the BS of the self-etching adhesive to dentin.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objectives: the purpose of this study is to employ optical microscopy to measure the thickness of the hybrid layer and the penetration (tags) of an aggressive self-etching adhesive system into sound dentin.Methods: occtusat cavities were prepared in 40 extracted human posterior teeth. The prepared teeth were randomly assigned to four experimental groups with 10 specimens each. The self-etching adhesive system Adper Prompt L-Pop was applied to the dentin surface as follows: Group 1: cavosurface enamel was etched for 60 s and dentin for 20 s with 35% phosphoric acid get, immediately followed by application of the self -etching adhesive with a brush to the entire cavity for 15 s; Groups 2, 3, and 4: no pre-etching was performed, and the self -etching adhesive was applied to both enamel and dentin for 15, 30 and 45 s, respectively. After curing, the cavities were fitted with composite resin Fittek Z250. Afterwards, the teeth were decalcified and the restorations were carefully removed for later embedding in paraffin. The specimens were serially sectioned at 6 mu m of thickness and sequentially mounted in glass slides. These sections were stained with Brown and Brenn staining for posterior analysis and measurement of the hybrid layer and resin tags on a tight microscope with a micrometric ocular 40/075. The results were submitted to analysis of variance at the 5% level.Results: whenever there was significance, the Tukey test was applied at the 5% level. The specimens receiving application of acid etching before the selfetching. adhesive displayed a larger thickness of the hybrid layer; on the other hand, specimens receiving only application of the self -etching adhesive on dentin for 15, 30 and 45 s exhibited similar thickness of the hybrid layer. As regards the resin tags, no statistically significant differences could be found between the study groups.Conclusions: it could be concluded that the increase in the time of application of the self-etching adhesive Adper Prompt L-Pop did not significantly influence the formation and thickness of hybrid layer, as well as its penetration into the sound dentin surface. (c) 2005 Elsevier Ltd. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The present study presents the morphology, histology, and the dynamics of vitellogenesis in females of the tick Amblyomma triste. The ovary in this species is of the panoistic type, therefore it lacks nurse cells. It is composed of a layer of epithelial cells that outwardly form the wall of the ovary, but also originate the pedicel, the structure that attaches the oocytes to its external margin, as well the oocytes themselves. In Amblyomma triste, the oocytes develop in four synchronic stages, which differs from the process in other tick species. The classification of the stages of the oocytes was carried out based on the presence of four morphologic characteristics: cytoplasm appearance; site of the germ vesicle; presence, quantity, and constitution of the yolk granules and presence of chorium. (c) 2006 Elsevier B.V. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose: To test the null hypothesis that beveling and/or etching enamel would not affect the 18-month clinical performance of the self-etching adhesive Clearfil SE Bond (CSEB) in noncarious cervical lesions (NCCL). Methods: With Institutional Review Board approval, 34 patients were enrolled in this study. A total of 120 NCCL was selected and assigned to four groups: (1) CSEB was applied without any cavity preparation; (2) CSEB was applied after beveling enamel; (3) CSEB was applied after etching enamel for 15 seconds with 35% phosphoric acid; (4) CSEB was applied after beveling and etching enamel. A microfilled composite resin was used for all restorations. Resuts: At 6 months after initial placement, 120 restorations (a 100% recall rate) were evaluated. At 18 months, 87 restorations (a 72.5% recall rate) were available for evaluation. A survival rate of 100% was measured for all groups at both 6 and 18 months. Sensitivity to air decreased significantly only for Group 3 (no bevel+acid etch) from baseline to 18 months without statistical changes from 6 months to 18 months. None of the other parameters resulted in significant differences for any of the four groups. However, when data were pooled, both the overall marginal discoloration and the overall marginal adaptation were significantly worse at 18 months than at baseline, while sensitivity to air decreased significantly from baseline to 18 months. The 18-month survival rate of the self-etching adhesive Clearfil SE Bond was not improved by enamel bevel or by enamel etching. Both overall marginal adaptation and overall marginal discoloration were worse at 18 months than at baseline.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The chromosomic constitution of the Marsh Deer (Blastocerus dichotomus) was studied in 18 males and 18 females, mainly from the Tiete river basin in Sao Paulo State, Brazil. The species diploid number was determined to be 66 chromosomes and the fundamental number (FN), 74. The X and the Y were the largest and the smallest chromosome, respectively. Large amounts of the constitutive heterochromatin marked by the C band were located in the centromeric region of all the acrocentric chromosomes. The first chromosome pair was not marked and the second and third pairs showed weak centromeric markings. The X chromosome showed two strong telomeric markings while the Y was C band negative. Chromosomes four and five were the NOR carriers. Polymorphism for this band was observed in pair four. The results of this study are in agreement with other reports in the literature, in spite of the different origin of the animals.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The authors admit that the conjunctive-muscular constitution of the walls of the superior venae cavae throughout the length of the intrapericardium segment and the debouchement in the right atrium, associated with the presence of a myocardium sheath can be made up of a functional device of sphincter form able to act on the control of the blood flow to the interior of the arterial chamber as well as stopping blood flow during the arterial systole. The fixation of the venous wall to the deep chamber of the serous pericardium, contributes to growth in resistance during the elevation of venous pressure, making possible the preservation of integrity of the superior venae cavae. The expansion of fasciculi of nodal fibers in the right wall of the superior venae cavae permits that the unlocked impulse in the S-A node also reaches the vascular wall contributing to the shortening and diminution in caliber of the vein.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Following the study of the Topologically Massive Theories under the Hamilton-Jacobi, we now analyze the constraint structure of the Self-Dual model as well as its correspondence with the Topologically Massive Electrodynamics. © 2013 American Institute of Physics.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

1. 1. Total hemolysates of Synbranchus marmoratus Bloch, 1795, captured in Vitoriana, district of Botucatu, State of São Paulo, Brazil, were submitted to agar-starch gel electrophoresis on glass slides using 42 mM-Tris 1.7 mM EDTA-6.1 mM borate buffer, pH 8.8, for the gel and 10 mM borate-1.7 mM NaOH buffer, pH 8.6, for the cuvette. 2. 2. Three distinct hemoglobin bands were detected, with Hb I being of the cathodic type. 3. 3. Cellulose acetate electrophoresis in 800 mM Tris-2.1 mM EDTA buffer, pH 8.9, containing 6 M urea and 2.25 mM β-mercaptoethanol indicated the presence of four globin chains denoted α 1, α 2, β and γ. 4. 4. It is suggested that the probable tetrameric constitution of the hemoglobin of Synbranchus marmoratus Bloch, 1795 is Hb I (α 2 2γ 2), Hb II (α 2 1γ 2) and Hb III (α 2 1β 2). © 1986.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objectives: The incorporation of antibacterial agents into adhesive systems has been proposed to eliminate residual bacteria from dentine. This study used the agar diffusion method to evaluate the antibacterial activity of Clearfil Protect Bond (CPB), Clearfil SE Bond (CSEB), Clearfil Tri-S Bond (C3SB) and Xeno-III (XIII) self-etching adhesive systems, with or without light-activation, against cariogenic bacteria, and to assess the influence of human dentine on the antibacterial activity of these materials.Methods: An aliquot of 10 mu l per material (and individual components) were pipetted onto paper and dentine discs distributed in Petri dishes containing bacterial culture in BHI agar. Positive control was 0.2% chlorhexidine digluconate (CHX).Results: After incubation, the adhesive components of CPB and CSEB, liquid A of XIII and C3SB did not present antibacterial activity when applied to paper discs. The non-light-activated CPB primer + adhesive promoted the greatest inhibition of Streptococcus mutans (p < 0.05), whereas with light-activation, there was no significant difference between primer + adhesive and primer alone. For Lactobacillus acidophilus, CPB primer presented the greatest antibacterial activity in both light-activation conditions (p < 0.05). Regarding the dentine discs, only CHX promoted an inhibitory effect, though less intense than on paper discs (p < 0.05). CHX presented greater antibacterial activity against S. mutans than against L. acidophilus (p < 0.05).Conclusions: Light-activation significantly reduced the antibacterial activity of the self-etching adhesive systems; MDPB incorporation contributed to the effect of adhesive systems against cariogenic bacteria; the components eluted from the adhesive systems were not capable to diffuse through 400 mu m-thick dentine disc to exert their antibacterial activity against cariogenic bacteria. (C) 2008 Elsevier Ltd. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background and Objectives. The adhesion of dental materials is important for the success of treatment. The aim of this study is to evaluate the bond strength of a composite resin applied with a self-etching adhesive system in different dentins after irradiation with Er:YAG and Nd:YAG lasers, observing their morphologic pattern using Scanning Electronic Microscopy (SEM). Materials and Methods. The buccal surface of 72 bovine incisors was worn until exposure of medium depth dentin. The specimens were divided into three groups; GI: normal, GII: demineralized and GIII: hypermineralized dentin. These were also divided into two subgroups; A-irradiated for 30 s with Er:YAG laser in noncontact mode at 40 mJ and 6 Hz and B- irradiated for 30 s with Nd:YAG laser in contact mode at 60 mJ and 10 Hz. The adhesive system Clearfil SE. Bond (Kuraray) and composite resin Tetric Ceram (Vivadent) were applied on the irradiated area by the incremental technique. After storage for 24 h in distilled water at 37 degrees C, the specimens were submitted to the shear strength test in a universal testing machine (EMIC) at a crosshead speed of 1.0 mm/min. Other specimens were made to be analyzed by SEM. Results. The results were statistically analyzed by Analysis of Variance and the Tukey test. Regardless of the type of dentin, the bond strength of specimens irradiated with the Nd:YAG laser (8,94 +/- 2,07) was higher compared to specimens irradiated with the Er:YAG laser (7,03 +/- 2,47); the highest bond strength was obtained for the group of hypermineralized dentin irradiated with the Nd:YAG laser. The SEM analysis showed that the Er:YAG laser caused opening of tubules and the Nd:YAG laser produced areas of fusion as well as regions of opening of dentinal tubules. Conclusions. The dentin showed different morphological patterns and the laser promote alterations on their surfaces, influencing the bond strength of the composite resin. (C) 2010 Laser Institute of America.