90 resultados para Constant-pressure conditions

em Repositório Institucional UNESP - Universidade Estadual Paulista "Julio de Mesquita Filho"


Relevância:

100.00% 100.00%

Publicador:

Resumo:

We report on the realization of a capacitive dilatometer, designed for high-resolution measurements of length changes of a material for temperatures 1.4K ≤ T ≤ 300K and hydrostatic pressure P ≤ 250MPa. Helium ( 4He) is used as a pressure-transmitting medium, ensuring hydrostatic-pressure conditions. Special emphasis has been given to guarantee, to a good approximation, constant-pressure conditions during temperature sweeps. The performance of the dilatometer is demonstrated by measurements of the coefficient of thermal expansion at pressures P ≃ 0.1MPa (ambient pressure) and 104MPa on a single crystal of azurite, Cu 3(CO 3) 2(OH) 2, a quasi-one-dimensional spin S = 1/2 Heisenberg antiferromagnet. The results indicate a strong effect of pressure on the magnetic interactions in this system. © 2012 American Institute of Physics.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Several machining processes have been created and improved in order to achieve the best results ever accomplished in hard and difficult to machine materials. Some of these abrasive manufacturing processes emerging on the science frontier can be defined as ultra-precision grinding. For finishing flat surfaces, researchers have been putting together the main advantages of traditional abrasive processes such as face grinding with constant pressure, fixed abrasives for two-body removal mechanism, total contact of the part with the tool, and lapping kinematics as well as some specific operations to keep grinding wheel sharpness and form. In the present work, both U d-lap grinding process and its machine tool were studied aiming nanometric finishing on flat metallic surfaces. Such hypothesis was investigated on AISI 420 stainless steel workpieces U d-lap ground with different values of overlap factor on dressing (Ud=1, 3, and 5) and grit sizes of conventional grinding wheels (silicon carbide (SiC)=#800, #600, and #300) applying a new machine tool especially designed and built for such finishing. The best results, obtained after 10 min of machining, were average surface roughness (Ra) of 1.92 nm, 1.19-μm flatness deviation of 25.4-mm-diameter workpieces, and mirrored surface finishing. Given the surface quality achieved, the U d-lap grinding process can be included among the ultra-precision abrasive processes and, depending on the application, the chaining steps of grinding, lapping, and polishing can be replaced by the proposed abrasive process.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paperaims to determine the velocity profile, in transient state, for a parallel incompressible flow known as Couette flow. The Navier-Stokes equations were applied upon this flow. Analytical solutions, based in Fourier series and integral transforms, were obtained for the one-dimensional transient Couette flow, taking into account constant and time-dependent pressure gradients acting on the fluid since the same instant when the plate starts it´s movement. Taking advantage of the orthogonality and superposition properties solutions were foundfor both considered cases. Considering a time-dependent pressure gradient, it was found a general solution for the Couette flow for a particular time function. It was found that the solution for a time-dependent pressure gradient includes the solutions for a zero pressure gradient and for a constant pressure gradient.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

O objetivo deste trabalho foi avaliar os efeitos de surfatantes e pontas de pulverização na deposição da calda de pulverização em plantas de Cynodon dactylon. Os tratamentos foram dispostos em um esquema fatorial 2 x 5, sendo duas pontas de pulverização (XR 11002 e TX-VK 8) e cinco caldas de pulverização (sem surfatante e com os surfatantes Aterbane e Silwet a 0,05% e 0,1%). As caldas foram preparadas utilizando-se o corante FDC-1 a 1.500 ppm como traçador. O delineamento experimental foi o inteiramente casualizado, com 10 repetições. As aplicações foram realizadas através de um pulverizador estacionário a pressão constante e com consumo de calda de 150 L ha-1. A ponta de pulverização do tipo jato cônico vazio proporcionou maior deposição nas folhas de grama-seda, quando comparada com a ponta do tipo jato plano, independentemente do adjuvante utilizado. As maiores deposições ocorreram nas doses de 0,1%, para ambos os surfatantes, quando utilizada a ponta de jato plano e para o Silwet a 0,05% pulverizado com a ponta de jato cônico. A deposição de calda nas folhas foi menor quando da não-adição de surfatante, independentemente da ponta de pulverização utilizada.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

This study investigated the effect of an Argon-based atmospheric pressure plasma (APP) surface treatment operated chairside at atmospheric pressure conditions applied immediately prior to dental implant placement in a canine model. Surfaces investigated comprised: rough titanium surface (Ti) and rough titanium surface + Argon-based APP (Ti-Plasma). Surface energy was characterized by the Owens-Wendt-Rabel-Kaelble method and chemistry by X-ray photoelectron spectroscopy (XPS). Six adult beagles dogs received two plateau-root form implants (n = 1 each surface) in each radii, providing implants that remained 1 and 3 weeks in vivo. Histometric parameters assessed were bone-to-implant contact (BIC) and bone area fraction occupancy (BAFO). Statistical analysis was performed by Kruskall-Wallis (95% level of significance) and Dunn's post-hoc test. The XPS analysis showed peaks of Ti, C, and O for the Ti and Ti- Plasma surfaces. Both surfaces presented carbon primarily as hydrocarbon (C?C, C?H) with lower levels of oxidized carbon forms. The Ti-Plasma presented large increase in the Ti (+11%) and O (+16%) elements for the Ti- Plasma group along with a decrease of 23% in surface-adsorbed C content. At 1 week no difference was found in histometric parameters between groups. At 3 weeks significantly higher BIC (>300%) and mean BAFO (>30%) were observed for Ti-Plasma treated surfaces. From a morphologic standpoint, improved interaction between connective tissue was observed at 1 week, likely leading to more uniform and higher bone formation at 3 weeks for the Ti-Plasma treated implants was observed. (C) 2012 Wiley Periodicals, Inc. J Biomed Mater Res Part A 2012.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Pós-graduação em Agronomia (Irrigação e Drenagem) - FCA

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

80.00% 80.00%

Publicador:

Resumo:

In this work, we report a 20-ns constant pressure molecular dynamics simulation of prilocaine (PLC), in amine-amide local anesthetic, in a hydrated liquid crystal bilayer of 1-palmitoyl-2-oleoyl-sn-glycero-3-phosphatidylcholine. The partition of PLC induces the lateral expansion of the bilayer and a concomitant contraction in its thickness. PLC molecules are preferentially found in the hydrophobic acyl chains region, with a maximum probability at similar to 12 angstrom from the center of the bilayer (between the C(4) and C(5) methylene groups). A decrease in the acyl chain segmental order parameter, vertical bar S-CD vertical bar, compared to neat bilayers, is found, in good agreement with experimental H-2-NMR studies. The decrease in vertical bar S-CD vertical bar induced by PLC is attributed to a larger accessible volume per lipid in the acyl chain region. (C) 2008 Wiley Periodicals, Inc.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Studies were conducted at Estacao Experimental de Citricultura de Bebedouro, SP to evaluate the response of glyphosate-resistant horseweed and hairy fleabane biotypes to herbicides glyphosate, bromacil + diuron, diuron e paraquat isolated and in mixture and effect of a sequential application of glyphosate. The experimental design was of complete randomized blocks with four replication and seven treatments. The herbicides were applied with costal sprayer, constant pressure with three nozzles TT110015, the equivalent spray volume was 150 L ha(-1). The control was visually evaluated, trough percentile note scale. The best results were obtained to general control of weed with diuron isolated and glyphosate in mixture with bromacil + diuron while to glyphosate-resistant horseweed and hairy fleabane there was no difference between the treatments. After sequential application to Conyza sp control, the best treatment was obtained associated with diuron and bromacil+diuron.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Apesar de possuir boa ação herbicida, alguns fatores afetam a eficácia do glifosato e, nesse contexto, realizaram-se estudos buscando formulações mais eficazes. O experimento foi instalado em área do Campus da FCAV-UNESP, Jaboticabal (SP). Testou-se a formulação potássica de glifosato comparada com solução aquosa e grânulos dispersíveis em água à mesma dosagem (0,36 kg.ha-1 e.a) em cinco intervalos (1, 2, 4, 6 e > 48 horas) sem chuva após a aplicação, comparados com uma testemunha sem uso de herbicidas. Foram aplicados em pós-emergência sobre Brachiaria plantaginea, B. decumbens e Digitaria horizontalis. A aplicação foi feita com pulverizador costal a CO2, à pressão de 2,5 kg.cm-2, munido de barra com seis bicos DG 110.02 e consumo de calda equivalente a 200 L.ha-1. Realizaram-se cinco avaliações de porcentagem de controle em relação à testemunha infestada, atribuídas visualmente, até 42 dias após aplicação. Notou-se que o controle da formulação potássica sobre as espécies avaliadas foi mais precoce, necessitando apenas quatro horas após sua aplicação para se igualar ao intervalo superior a 48 horas sem chuva. As demais necessitaram de, no mínimo, seis horas de intervalo.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Avaliou-se a eficácia do herbicida glifosato potássico, comparado ao sulfosato e ao glifosato amínico, utilizados como padrões comerciais. Os herbicidas foram aplicados em um pomar de laranja da variedade Pêra-rio, infestado por grama-seda (Cynodon dactylon) com aproximadamente 25 cm de altura, em 70% da área. O experimento foi instalado no município de Taiúva-SP, em solo Podzólico Vermelho-Amarelo, distrófico, de textura arenosa, com relevo suave ondulado. Os tratamentos testados foram: glifosato potássico (ZAPP Qi) a 1,05; 2,10 e 2,50 kg e.a./ha, sulfosato (ZAPP) e glifosato amínico (ROUNDUP CS) a 1,98 e 2,16 kg e.a./ha, respectivamente, além da testemunha sem capina. Os herbicidas foram aplicados em pós-emergência da planta daninha, com pulverizador costal, à pressão constante (mantida por CO2 comprimido) de 2,5 kg/cm², munido de barra com seis bicos de jato plano (leque) DG 11002, com um consumo de calda equivalente a 200 L/ha. Os melhores resultados de controle foram obtidos com 2,5 kg e.a./ha do glifosato potássico, que também garantiu menor brotação da grama-seda. No entanto, a dosagem de 2,10 kg e.a./ha deste mesmo herbicida não foi menos eficaz que o sulfosato e o glifosato, com 1,98 e 2,16 kg e.a./ha, respectivamente.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Durante a fase de desenvolvimento de novos produtos fitossanitários é comumente utilizado o pulverizador a pressão constante, pressurizado com CO2. O gás carbônico pode provocar a acidificação da água e afetar o comportamento do composto que está sendo avaliado. No presente trabalho, amostras de água de 30 diferentes fontes foram pressurizadas com CO2 durante cinco minutos, até 275 kPa (40 lbf/pol.2), e o pH foi medido na água que saiu do bico e na água no inteior do tanque do pulverizador. Os resultados mostraram redução nos valores do pH em toda as amostras . Os valores do pH elevaram-se ligeiramente após a saída da água pelo bico do pulverizador. A redução, em alguns casos, foi marcante, atingindo 4,91 unidades de pH no caso mais drástico. Esses dados levam a recomendar cautela na interpretação dos resultados obtidos com o uso dos pulverizadores pressurizados com o gás carbônico.