65 resultados para Conservation Area Networks
em Repositório Institucional UNESP - Universidade Estadual Paulista "Julio de Mesquita Filho"
Resumo:
In this paper a three-phase power flow for electrical distribution systems considering different models of voltage regulators is presented. A voltage regulator (VR) is an equipment that maintains the voltage level in a predefined value in a distribution line in spite of the load variations within its nominal power. Three different types of connections are analyzed: 1) wye-connected regulators, 2) open delta-connected regulators and 3) closed delta-connected regulators. To calculate the power flow, the three-phase backward/forward sweep algorithm is used. The methodology is tested on the IEEE 34 bus distribution system. ©2008 IEEE.
Resumo:
This paper presents a model for the control of the radiation pattern of a circular array of antennas, shaping it to address the radiation beam in the direction of the user, in order to reduce the transmitted power and to attenuate interference. The control of the array is based on Artificial Neural Networks (ANN) of the type RBF (Radial Basis Functions), trained from samples generated by the Wiener equation. The obtained results suggest that the objective was reached.
Resumo:
The high active and reactive power level demanded by the distribution systems, the growth of consuming centers, and the long lines of the distribution systems result in voltage variations in the busses compromising the quality of energy supplied. To ensure the energy quality supplied in the distribution system short-term planning, some devices and actions are used to implement an effective control of voltage, reactive power, and power factor of the network. Among these devices and actions are the voltage regulators (VRs) and capacitor banks (CBs), as well as exchanging the conductors sizes of distribution lines. This paper presents a methodology based on the Non-Dominated Sorting Genetic Algorithm (NSGA-II) for optimized allocation of VRs, CBs, and exchange of conductors in radial distribution systems. The Multiobjective Genetic Algorithm (MGA) is aided by an inference process developed using fuzzy logic, which applies specialized knowledge to achieve the reduction of the search space for the allocation of CBs and VRs.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
The distribution, activity, diet, and reproduction of an undescribed catfish species of the genus Trichomycterus (Trichomycteridae) were studied in the Morro do Diabo State Park, an important conservation area in the Rio Paranapanema basin, State of São Paulo, southeastern Brazil. Trichomycterus sp. is a rheophilic species occurring solely in the riffle areas of the streams and hunts mostly immature aquatic insects during the day by picking them from the substrate. The population has a balanced sex ratio, but females were uncommon in the smallest and largest size classes suggesting that females demonstrate a more accelerated growth pattern. Presence of mature individuals throughout the year represents an opportunistic reproductive tactic for fishes living in fast flowing waters, where the clutches could be shifted by the current, but the high incidence of mature individuals in the wet season may be related to optimal environmental conditions for juveniles during that period. Because of the restriction of Trichomycterus sp. to riffle environments, the conservation of this species depends on the maintenance of the original characteristics of these headwaters. That demands protecting the riparian vegetation and consequently the stream from excessive siltation resulting from runoff and erosion.
Resumo:
O comportamento reprodutivo e a ocorrência sazonal de Psecas viridipurpureus foram estudados na Estação Ecológica do Noroeste Paulista, uma pequena área de conservação na região noroeste do Estado de São Paulo, Brasil (49º22'50W e 20º48'36S). P. viridipurpureus ocorreu em gravatás, uma bromeliácea (Bromelia balansae, Bromeliaceae) que não acumula água de chuva. Durante a exibição de corte, o casal ocupou a região mediana das folhas de gravatás, com o macho sempre localizado em uma posição superior à da fêmea. Os machos de P. viridipurpureus apresentaram um comportamento de corte complexo, que incluiu cinco padrões motores. O comportamento de corte e a cópula ocorreram preponderantemente durante a estação chuvosa e o recrutamento de jovens entre dezembro e julho. O abrigo de P. viridipurpureus difere do padrão de Salticidae, pois as ootecas são recobertas por uma cobertura de seda plana e não são incluídas em casulos.
Resumo:
This work had as objective to quantify the reforestation for water retention in the Palmital Stream watershed, County of Jaboticabal, SP, by using the methodology of compensatory forestation for retention of water in watersheds. This methodology esteems the retention of water in watersheds considering the world medium value of destiny of the water in the hydrologic cycle, the use/occupation of the soil (forest, pasture and agriculture) and its permeability. The watershed in this study presents an area of 10,625.21 ha, being 237.75 ha at forest, 467.01 ha in pasture and 9,237.57 ha in agriculture. The medium values of the permeability identified in the soils were of 94.81 mm h -1 in forest, 8.99 mm t -1 in pasture and 36.01 mm h -1 in agriculture (sugar cane). Considering that should infiltrate in the soil 20.55% of the water that precipitates on the watershed, and, that the losses of water in forest areas is considered standard, the total estimated volume to compensate the excessive loss that occur in the areas of pasture and agriculture is 12.21 million of m 3ano. The compensatory forestation to retain that volume of loss should contemplate an area of 942.73 ha (8.87% of the area of the watershed). The reforestation can be priority in permanent conservation area or in areas of Legal Reserve.
Resumo:
Regulatory authorities in many countries, in order to maintain an acceptable balance between appropriate customer service qualities and costs, are introducing a performance-based regulation. These regulations impose penalties, and in some cases rewards, which introduce a component of financial risk to an electric power utility due to the uncertainty associated with preserving a specific level of system reliability. In Brazil, for instance, one of the reliability indices receiving special attention by the utilities is the Maximum Continuous Interruption Duration per customer (MCID). This paper describes a chronological Monte Carlo simulation approach to evaluate probability distributions of reliability indices, including the MCID, and the corresponding penalties. In order to get the desired efficiency, modern computational techniques are used for modeling (UML -Unified Modeling Language) as well as for programming (Object- Oriented Programming). Case studies on a simple distribution network and on real Brazilian distribution systems are presented and discussed. © Copyright KTH 2006.
Resumo:
In an evermore competitive environment, power distribution companies need to continuously monitor and improve the reliability indices of their systems. The network reconfiguration (NR) of a distribution system is a technique that well adapts to this new deregulated environment for it allows improvement of system reliability indices without the onus involved in procuring new equipment. This paper presents a reliability-based NR methodology that uses metaheuristic techniques to search for the optimal network configuration. Three metaheuristics, i.e. Tabu Search, Evolution Strategy, and Differential Evolution, are tested using a Brazilian distribution network and the results are discussed. © 2009 IEEE.
Resumo:
A method for spatial electric load forecasting using multi-agent systems, especially suited to simulate the local effect of special loads in distribution systems is presented. The method based on multi-agent systems uses two kinds of agents: reactive and proactive. The reactive agents represent each sub-zone in the service zone, characterizing each one with their corresponding load level, represented in a real number, and their relationships with other sub-zones represented in development probabilities. The proactive agent carry the new load expected to be allocated because of the new special load, this agent distribute the new load in a propagation pattern. The results are presented with maps of future expected load levels in the service zone. The method is tested with data from a mid-size city real distribution system, simulating the effect of a load with attraction and repulsion attributes. The method presents good results and performance. © 2011 IEEE.
Resumo:
This work proposes a methodology for optimized allocation of switches for automatic load transfer in distribution systems in order to improve the reliability indexes by restoring such systems which present voltage classes of 23 to 35 kV and radial topology. The automatic switches must be allocated on the system in order to transfer load remotely among the sources at the substations. The problem of switch allocation is formulated as nonlinear constrained mixed integer programming model subject to a set of economical and physical constraints. A dedicated Tabu Search (TS) algorithm is proposed to solve this model. The proposed methodology is tested for a large real-life distribution system. © 2011 IEEE.
Resumo:
This paper presents a mixed-integer linear programming approach to solving the optimal fixed/switched capacitors allocation (OCA) problem in radial distribution systems with distributed generation. The use of a mixed-integer linear formulation guarantees convergence to optimality using existing optimization software. The results of one test system and one real distribution system are presented in order to show the accuracy as well as the efficiency of the proposed solution technique. © 2011 IEEE.
Resumo:
In this paper the point estimation method is applied to solve the probabilistic power flow problem for unbalanced three-phase distribution systems. Through the implementation of this method the probability distribution functions of voltages (magnitude and angle) as well as the active and reactive power flows in the branches of the distribution system are determined. Two different approaches of the point estimation method are presented (2m and 2m+1 point schemes). In order to test the proposed methodology, the IEEE 34 and 123 bus test systems are used. The results obtained with both schemes are compared with the ones obtained by a Monte Carlo Simulation (MCS).
Resumo:
A multi-agent system with a percolation approach to simulate the driving pattern of Plug-In Electric Vehicle (PEV), especially suited to simulate the PEVs behavior on any distribution systems, is presented. This tool intends to complement information about the driving patterns database on systems where that kind of information is not available. So, this paper aims to provide a framework that is able to work with any kind of technology and load generated of PEVs. The service zone is divided into several sub-zones, each subzone is considered as an independent agent identified with corresponding load level, and their relationships with the neighboring zones are represented as network probabilities. A percolation approach is used to characterize the autonomy of the battery of the PVEs to move through the city. The methodology is tested with data from a mid-size city real distribution system. The result shows the sub-area where the battery of PEVs will need to be recharge and gives the planners of distribution systems the necessary input for a medium to long term network planning in a smart grid environment. © 2012 IEEE.