85 resultados para Computerized tomography
em Repositório Institucional UNESP - Universidade Estadual Paulista "Julio de Mesquita Filho"
Resumo:
Background: Accurate early diagnosis of lung metastases is important for establishing therapeutic measures. Therefore, the present study aimed to compare survey thoracic radiographs and computerized tomography (CT) scans to specifically identify lung metastases in female dogs with mammary tumors.Methods: Twenty-one female dogs, weighing 3 to 34 kg and aged from 5 years to 14 years and 10 months, with mammary tumors were studied. In all dogs before the imaging examinations, fine-needle aspiration cytology of the mammary tumors was performed to confirm the diagnosis. Three-view thoracic radiographs were accomplished: right lateral, left lateral and ventrodorsal views. Sequential transverse images of the thorax were acquired on a spiral Scanner, before and after intravenous bolus injection of nonionic iodine contrast. Soft-tissue and lung windows were applied. All the mammary tumors were surgically removed and examined histologically.Results: The correlation between the cytological and histological results regarding presence of malignancy was observed in only 17 cases. In radiographic examinations, no dog displayed signs of lung metastases or thorax chest lesions. CT detected lung metastasis in two cases, while small areas of lung atelectasis located peripherally were found in 28.57% of the dogs.Conclusion: In this study population, spiral CT showed higher sensitivity than chest radiographies to detect lung metastasis; this indicates that CT should be performed on all female dogs with malignant mammary tumors.
Resumo:
Computerized tomography (CT) is a valuable tool for diagnosis and planning in conventional and surgical endodontic therapy. This case report describes the use of CT in the diagnosis of a periapical lesion undetected by periapical radiography in the mandibular molar area. The CT also showed a possible mesial root perforation associated with the lesion. Following CT, surgical planning, periradicular curettage, and sealing of the root perforation were performed. Eight years after surgery, cone beam CT revealed periapical bone repair. Computerized tomography can be an important resource for diagnosis and planning in conventional and surgical endodontic therapy, as well as for evaluation of post-treatment bone repair. (Oral Surg Oral Med Oral Pathol Oral Radiol Endod 2010; 109: 629-633)
Resumo:
X-ray computed tomography (CT) refers to the cross-sectional imaging of an object measuring the transmitted radiation at different directions. In this work, we describe a non-conventional application of computerized tomography: visualization and improvements in the understanding of some internal structural features of solid dosage forms. A micro-CT X-ray scanner, with a minimum resolution of 30 μm was used to characterize some pharmaceutical tablets, granules, controlled-release osmotic tablet and liquid-filled soft-gelatin capsules. The analysis presented in this work are essentially qualitative, but quantitative parameters, such as porosity, density distribution, tablets dimensions, etc. could also be obtained using the related CT techniques. © 2010 American Institute of Physics.
Resumo:
A finite element analysis was used to compare the effect of different designs of implant-retained overdentures and fixed full-arch implant-supported prosthesis on stress distribution in edentulous mandible. Four models of an human mandible were constructed. In the OR (O'ring) group, the mandible was restored with an overdenture retained by four unsplinted implants with O'ring attachment; in the BC (bar-clip) -C and BC groups, the mandibles were restored with overdentures retained by four splinted implants with bar-clip anchor associated or not with two distally placed cantilevers, respectively; in the FD (fixed denture) group, the mandible was restored with a fixed full-arch four-implant-supported prosthesis. Models were supported by the masticatory muscles and temporomandibular joints. A 100-N oblique load was applied on the left first molar. Von Mises (σvM), maximum (σmax) and minimum (σmin) principal stresses (in MPa) analyses were obtained. BC-C group exhibited the highest stress values (σvM=398.8, σmax=580.5 and σmin=-455.2) while FD group showed the lowest one (σvM=128.9, σmax=185.9 and σmin=-172.1). Within overdenture groups, the use of unsplinted implants reduced the stress level in the implant/prosthetic components (59.4% for σvM, 66.2% for σmax and 57.7% for σmin versus BC-C group) and supporting tissues (maximum stress reduction of 72% and 79.5% for σmax, and 15.7% and 85.7% for σmin on the cortical and trabecular bones, respectively). Cortical bone exhibited greater stress concentration than the trabecular bone for all groups. The use of fixed implant dentures and removable dentures retained by unsplinted implants to rehabilitate edentulous mandible reduced the stresses in the periimplant bone tissue, mucosa and implant/prosthetic components. © 2013 Elsevier Ltd.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
There is substantial controversy in literature about human dermatomes. In this work, C5 and C6 superior limb dermatomes were studied. The method consisted of comparing clinical signs and symptoms with conduction studies, electromyographical data, neurosurgical findings, and imaging findings obtained by computerized tomography (CT) or magnetic resonance imaging (MRI), for each patient. Data analysis from superior members in 18 patients suggests that C5 is located in the lateral aspect of the shoulder and arm, and C6 in the lateral aspect of the forearm and 1(st), 2(nd), and 3(rd) fingers. To our knowledge this is the first time that C5 and C6 human dermatomes have been studied by all the following methods together: clinical, electromyographical, CT and MR imaging, and surgical findings.
Resumo:
There is substantial controversy in literature about human dermatomes. We studied L4, L5, and S1 inferior limb dermatomes by comparing clinical signs and symptoms with conduction studies, electromyographical data, neurosurgical findings, and imaging data from computerized tomography (CT) or magnetic resonance imaging (MRI). After analyzing 60 patients, we concluded that L4 is probably located in the medial aspect of the leg, L5 in the lateral aspect of the leg and foot dorsus, and S1 in the posterior aspect of the backside, tight, leg and plantar foot skin. This is the first time that these human dermatomes have been evaluated by combined analysis of clinical, electromyographical, neurosurgical, and imaging data.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
OBJETIVO: o presente estudo, de caráter prospectivo, objetivou avaliar a imagem da sutura palatina mediana em crianças submetidas à expansão rápida da maxila por meio de tomografia computadorizada, após a fase de contenção. METODOLOGIA: a amostra constou de 17 crianças de ambos os gêneros, na faixa etária compreendida entre 5 anos e 2 meses e 10 anos e 5 meses no início do tratamento, provenientes da Clínica de Ortodontia Interceptiva da Sociedade de Promoção Social do Fissurado Lábio-Palatal da Universidade de São Paulo (PROFIS-USP), Bauru/SP. Tomografias computadorizadas foram implementadas para avaliar o comportamento da sutura palatina mediana em diferentes momentos do tratamento. RESULTADOS E CONCLUSÕES: constatou-se que, após um período médio de 8 a 9 meses de contenção com o aparelho expansor, a sutura palatina mediana mostrou-se completamente ossificada, desde a região da espinha nasal anterior até a espinha nasal posterior. Tal informação esclarece o comportamento da sutura palatina mediana frente à expansão rápida da maxila e reitera o senso comum quanto ao caráter biológico do procedimento.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
The aim of the current study is to evaluate fresh-frozen human bone allografts (FHBAs) used in vertical ridge augmentation clinically and by computed tomography, and to analyze the resulting bone formation and graft resorption. Sixteen FHBAs were grafted in the maxillae and mandibles of 9 patients. The FHBAs, which were provided by the Musculoskeletal Tissue Bank of Marilia Hospital (Unioss), were frozen at -80A degrees C. After 7 months, dental implants were placed and bone parameters were evaluated. Vertical bone formation was measured by computerized tomography before (T0) and at 7 months (T1) after the surgical procedure. Bone graft resorption was measured clinically from a landmark screw head using a periodontal probe. The results were analyzed by Student's t-test. Significant differences existed in the bone formation values at T0 and T1, with an average change of 4.03 +/- A 1.69 mm. Bone graft resorption values were 1.0 +/- A 0.82 mm (20%). Implants were placed with varying insertion torque values (35-45 Ncm), and achieved primary stability. This study demonstrates that FHBAs promote satisfactory vertical bone formation with a low resorption rates, good density, and primary implant stability.
Resumo:
RACIONAL: O carcinoma basalóide escamoso ocorre com maior freqüência no trato aerodigestivo superior e raramente acomete o esôfago. OBJETIVO: Apresentar os aspectos clínico-patológicos e os atributos imunoistoquímicos de um paciente com carcinoma basalóide escamoso do esôfago. RELATO do CASO: Dos 134 pacientes com câncer do esôfago atendidos no Hospital Universitário de Botucatu-Unesp, São Paulo, de 1990 a 1999, somente um paciente (0,74%) apresentou carcinoma basalóide escamoso do esôfago. Tratava-se de paciente masculino, 41 anos, branco, lavrador com disfagia, regurgitação e emagrecimento há três meses. Referia tabagismo e etilismo há muitos anos. O esofagograma e o exame endoscópico revelaram lesão vegetante no terço distal do esôfago. A biópsia demonstrou neoplasia intraepitelial de alto grau associada a blocos de células basalóides que infiltravam o cório da mucosa, caracterizando o carcinoma basalóide escamoso. Os marcadores imunoistoquímicos foram positivos para o antígeno carcinoembriônico e para citoceratinas de alto peso molecular. A tomografia computadorizada revelou múltiplas metástases nos pulmões, fígado, e nódulos linfáticos regionais, documentando a fase avançada de evolução da doença. O tratamento consistiu apenas na realização de gastrostomia. O paciente apresentou queda acentuada do estado geral e evoluiu para óbito com quadro de melena quatro meses após o diagnóstico. CONCLUSÃO: O carcinoma basalóide escamoso é uma forma rara e agressiva de câncer do esôfago e o prognóstico depende do estadiamento da lesão e das condições clínicas do paciente no momento do diagnóstico.
Resumo:
Dois pacientes índices da família analisada neste estudo foram submetidos a adrenalectomia bilateral devido a feocromocitoma. Foi, então, realizado o estudo genético dos pacientes e de sete parentes de primeiro grau. Os dois pacientes com feocromocitoma e dois outros membros assintomáticos da família apresentaram a mutação c496G>T no exon 3 do gene VHL. A família perdeu seguimento médico. Três anos após a realização da avaliação genética, a irmã dos pacientes, portadora da mutação, foi encaminhada para o nosso serviço após uma gestação complicada por pré-eclampsia. Ela referia paroxismos sugestivos de feocromocitoma, mas as metanefrinas urinárias eram negativas. Entretanto, a tomografia computadorizada de abdômen evidenciou uma massa adrenal que também se contrastou na cintilografia com metaiodobenzilguanidina (MIBG). Esse estudo mostra que a análise molecular do paciente índice pode levar à identificação de parentes assintomáticos portadores da mutação. Além disso, mesmo com as metanefrinas urinárias negativas, a identificação de uma mutação específica levou a um aumento da suspeita e detecção de feocromocitoma na irmã dos afetados pela doença.
Resumo:
Proton computerized tomography deals with relatively thick targets like the human head or trunk. In this case precise analytical calculation of the proton final energy is a rather complicated task, thus the Monte Carlo simulation stands out as a solution. We used the GEANT4.8.2 code to calculate the proton final energy spectra after passing a thick Al absorber and compared it with the same conditions of the experimental data. The ICRU49, Ziegler85 and Ziegler2000 models from the low energy extension pack were used. The results were also compared with the SRIM2008 and MCNPX2.4 simulations, and with solutions of the Boltzmann transport equation in the Fokker-Planck approximation. (C) 2009 Elsevier Ltd. All rights reserved.