74 resultados para Cateter de Fogarty

em Repositório Institucional UNESP - Universidade Estadual Paulista "Julio de Mesquita Filho"


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Pós-graduação em Medicina Veterinária - FMVZ

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Cell therapy has frequently been reported as a possible treatment for spinal trauma in humans and animals; however, without pharmacologically curative action on damage from the primary lesion. In this study, we evaluated the effect of administering human adipose-derived stem cells (hADSC) in rats after spinal cord injury. The hADSC were used between the third and fifth passages and a proportion of cells were transduced for screening in vivo after transplantation. Spinal cord injury was induced with a Fogarty catheter no. 3 inserted into the epidural space with a cuff located at T8 and filled with 80 mu L saline for 5 min. The control group A (n = 12) received culture medium (50 mu L) and group B (n = 12) received hADSC (1.2 x 10(6)) at 7 and 14 days post-injury, in the tail vein. Emptying of the bladder by massage was performed daily for 3 months. Evaluation of functional motor activity was performed daily until 3 months post-injury using the Basso-Beattie-Bresnahan scale. Subsequently, the animals were euthanized and histological analysis of the urinary bladder and spinal cord was performed. Bioluminescence analysis revealed hADSC at the application site and lungs. There was improvement of urinary bladder function in 83.3% animals in group B and 16.66% animals in group A. The analysis of functional motor activity and histology of the spinal cord and urinary bladder demonstrated no significant difference between groups A and B. The results indicate that transplanted hADSC improved urinary function via a telecrine mechanism, namely action at a distance.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A hemodiálise é uma modalidade terapêutica que pode sustentar a vida do paciente com insuficiência renal aguda (IRA), enquanto este recupera a função renal. Para sua realização, é necessário estabelecer circulação extracorpórea, para que seja realizada a filtração do sangue, impondo a necessidade de um acesso vascular viável e eficiente. O objetivo deste estudo foi avaliar a eficiência e as complicações do acesso vascular para hemodiálise (HD), com cateter temporário de duplo lúmen inserido na veia jugular externa. Foram estudados 10 cães com IRA induzida por gentamicina, submetidos a sessões diárias de HD, com duração de uma hora, até a recuperação da função renal ou óbito. Foram realizadas 104 sessões de HD nos animais estudados, observando-se necessidade de troca do cateter em sete sessões (6,7%), devido à obstrução do lúmen do cateter em seis sessões (5,8%) ou por saída acidental do mesmo em uma sessão (1,0%). Não se observou migração do cateter, infecção, hemorragia ou hematoma no local de entrada do cateter na pele, obtendo-se fluxo sanguíneo patente em 90,4% das sessões. Concluiu-se que o acesso vascular na veia jugular externa com cateter temporário de duplo-lúmen mostrou-se viável, com ocorrência de poucas complicações, sendo, portanto, indicado como forma de acesso para a circulação extracorpórea para HD em cães com IRA.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Slime production is an important virulence factor of coagulase-negative Staphylococcus spp., allowing them to attach to smooth surfaces of biomaterials, and it has been associated with infections of implanted medical devices. In the present study the production of slime capsules in 27 strains of coagulase-negative Staphylococcus was investigated by culture in Congo Red agar (77.7% positivity), spectrophotometric or microplate method (81.4% positivity) and scanning electron microscopy (88.9% positivity). The resistance of coagulase-negative strains of Staphylococcus to various antimicrobial agents was also determined by agar disk diffusion. The proportion of strains resistant to penicillin G, oxacillin, erythromycin, clindamycin and gentamicin among the slime-producing staphylococci was 88.9%, 70.4%, 81.5%, 66.7% and 59.2%, respectively; all of the coagulase-negative staphylococci were susceptible to vancomycin. The strains isolated from central venous catheters were identified by a conventional method and the API Staph system. The 27 coagulase-negative Staphylococcus strains were identified as: S. saprophyticus (3.7%), S. xylosus (7.4%), S. haemolyticus (14.8%), S. epidermidis (37.0%), S. warneri (14.8%), S. lugdunensis (7.4%), S. hominis (7.4%), S. schleiferi (3.7%) and S. chromogenes (3.7%). It can be concluded that in the most of the coagulase-negative Staphylococcus species there was an association between slime production, the nosocomial origin of the strains and reduced sensitivity to the antibiotics, suggesting a pathogenic potential in the hospital environment.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The indwelling urethral catheter has an important role for patients with urinary retention, bladder obstruction, neurological damage and other diseases. Urine contains minerals which precipitate in alkaline pH, crystallize and block the urological catheter. The crystallization of the ionic components of urine occurs in the presence of urease, an enzyme produced by Proteus mirabilis. This bacterium adheres to inanimate surfaces and forms biofilms. The aim of this study was to investigate the formation of crystalline biofilm on the luminal surface of siliconized latex catheters by means of scanning electron microscope, after channeling artificial urine infected with Proteus mirabilis. The experiment was performed in vitro using a dynamic flow system. The artificial urine compounds were salts of calcium, magnesium, phosphates, urea and egg albumin, and it was infected with Proteus mirabilis ATCC 25933. The urine flow was stopped after crystallization of the ionic components. Crystallization was observed after alkalinization of urine. Scanning electron microscopy showed the presence of crystals and morphologies typical of bacilli embedded in an amorphous mass on the internal lumen of the catheter. The present study showed that catheter encrustation may limit the use of long-term indwelling catheter. © SBEB - Sociedade Brasileira de Engenharia Biomédica.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Pós-graduação em Bases Gerais da Cirurgia - FMB

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Pós-graduação em Biologia Geral e Aplicada - IBB

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Study the semi-quantitative and quantitative technique in the diagnosis of catheter-related infections in newborns and to determine oxacillin resistance in Staphylococcus isolated. It was analyzed 353 catheter tips from 273 newborns in the Neonatal Unit of Hospital FMB. To confirm the diagnosis of infection, were analyzed the clinical data of newborns, the presence of at least one positive blood culture and growth of ≥ 1000 CFU/mL on quantitative culture and/or ³15 UFC on semiquantitative culture, with the same microorganism isolation (species and drug sensitivity) in blood culture and no other focus of infection except the catheter. The disk diffusion technique was used to check similarity of strains and resistance to oxacillin. Of the 353 tips analyzed, 39 were included in this study as the inclusion criteria. The semiquantitative culture was positive in 26 (66.7%) catheters and quantitative culture was positive in 24 (61.5%). Of 273 patients, 19 (6.9%) had a diagnosis of catheter-related bloodstream Infection (CR-BSI). Of the 19 episodes of CR-BSI, S. epidermidis was the predominant etiological agent (84.2%). The resistance to the antibiotic methicillin was found in 14 (73.7%) strains of Staphylococcus. The semiquantitative method was more sensitive (79%) compared with the quantitative method (63%). The use of antibiotics may have influenced the sensitivity of the quantitative method as the microorganisms present in the lumen are exposed to higher concentrations of antibiotics administered via the catheter

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Pós-graduação em Cirurgia Veterinária - FCAV

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Pós-graduação em Enfermagem (mestrado profissional) - FMB

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)