305 resultados para Calibração de Câmaras
em Repositório Institucional UNESP - Universidade Estadual Paulista "Julio de Mesquita Filho"
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
This paper presents a proposal for the automation of the camera calibration process, locating and measuring image points in coded targets with sub-pixel precision. This automatic technique helps minimize localization errors, regardless of camera orientation and image scale. To develop this technique, several types of coded targets were analyzed and the ARUCO type was chosen due to its simplicity, ability to represent up to 1024 different targets and availability of source code implemented with the OpenCV library. ARUCO targets were generated and two calibration sheets were assembled to be used for the acquisition of images for camera calibration. The developed software can locate targets in the acquired images and it automatically extracts the coordinates of the four corners with sub-pixel accuracy. Experiments were conducted with real data showing that the targets are correctly identified unless excessive noise or fragmentation occurs mainly in the outer target square. The results with the calibration of a low cost camera showed that the process works and that the measurement accuracy of the corners achieves sub-pixel precision.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
The sources of betatherapy for clinical use in Brazil are, the vast majority of strontium-90, radioactive element that is not produced in the country, and therefore requires importation of international laboratories accredited by the International Atomic Energy Agency (IAEA).The use of these resources is always limited the crediting of characteristic values supplied by the manufacturer tables that provide the nominal value of activity and dose distribution to determine the irradiation time of the injury. The Institute of Nuclear Energy Research (IPEN / CNEN-SP) has recently researching the emission profile of these types of radiation sources, and some jobs are being developed with ionization chambers extrapolation for the purpose of standardizing a systematic calibration sources betatherapy. Other studies using parallel measures dosimeters (TLD's) and simulations with the Monte Carlo method. Radiological films have also been used in studies of applicators dosimetric analysis of strontium-90. This paper seeks to analyze the different methods for calibration of applicators betatherapy, already consolidated in studies by examining the advantages and disadvantages of each procedure
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Considering the growing use of digital cameras in Photogrammetric projects, especially in aerial survey, this paper presents tests and analyses of bundle block adjustment with additional parameters, using different mathematical models, and blocks of images acquired by the SAAPI digital acquisition system. Three blocks of images were processed by the LPS (Leica Photogrammetry Suite) software, in which five groups of additional parameters (AP) can be used: Bauer, Jacobsen, Ebner, Brown and Lens distortion. These AP's models were employed in the bundle block adjustment, and the results were analyzed based on the accuracy of the checking points and on the changes in these additional parameters. The obtained results showed that the Lens Distortion model allowed the best results.
Resumo:
Image acquisition systems based on multi-head arrangement of digital frame cameras, such as the commercial systems DMC, UltraCam, besides others, are attractive alternatives enabling larger imaging area when compared to a single frame camera. Considering that in these systems, cameras are tightly attached to an external mount, it is assumed that relative position and orientation between cameras are stable during image acquisition and, consequently, these constraint can be included in the calibration step. This constraint is acceptable because estimates of the relative orientation (RO) parameters between cameras, from previously estimated exterior orientation parameters, present higher and significant deviations than the expected physical variations, due to error propagation. In order to solve this problem, this work presents an approach based on simultaneous calibration of two or more cameras using constraints that state that the relative rotation matrix and the distance between the cameras head are stable. Experiments with images acquired by an arrangement of two Hasselblad H2D cameras were accomplished, without and with the mentioned constraints. The experiments showed that the calibration process with RO constraints allows better results than the approach based on single camera calibration, provided that the estimation has included only images with good target distribution.
Resumo:
Este estudo visou à obtenção das curvas de calibração de um equipamento de TDR (Time Domain Reflectometry) em cinco solos da região de Piracicaba, SP, e testou a adequação da calibração interna do equipamento e das curvas genéricas de calibração. As curvas ajustadas, em cada solo separadamente, apresentaram coeficientes de determinação (R²) da ordem de 0,99, e a curva ajustada para o conjunto de dados dos cinco solos apresentou R² = 0,976. A análise de erros-padrão de estimativa mostrou que as curvas genéricas não se prestam às aplicações mais sensíveis, tais como na determinação absoluta do conteúdo de água do solo. Os testes de comparação entre as curvas ajustadas, a curva genérica e a curva embutida no equipamento mostraram que a primeira é superior às demais. O estudo mostrou, também, que a curva de calibração embutida no equipamento é inadequada para as determinações de umidade nos cinco solos estudados.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Neste artigo, o legislativo municipal é analisado a partir de dois eixos: (1) a ênfase em suas características nacionais e regionais, com base em dados sobre a composição social e político-partidária do legislativo municipal no Brasil, no período de 1996, 2000 e 2004; e (2) os diferentes modos como os poderes legislativos locais de São Paulo e Santa Catarina percebem os poderes executivos no que se refere ao processo decisório.
Resumo:
In the present work, the basic concepts of radiometric, photometric and colorimetric calibration are presented, which were applied to three light-emitting diodes (LEDs) used to compose the different color sensations that the human eye perceives in the visible region of the electromagnetic spectrum. In this sense, an experimental setup comprising a LED drive circuit and a home-made integrating sphere was assembled for the initial radiometric and photometric calibration as well as to obtain a set of intensity and spectral combinations associated to different colorimetric CIE (Commission Internationale de l'Eclairage) coordinates. The reader can, therefore, understand, in a simple manner, the process of color composition inside a color monitor or display picture element (pixel ). © Sociedade Brasileira de Física.
Resumo:
Pós-graduação em Ciências Cartográficas - FCT
Resumo:
Pós-graduação em História - FCHS
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)