8 resultados para CONTRAST SENSITIVITY
em Repositório Institucional UNESP - Universidade Estadual Paulista "Julio de Mesquita Filho"
Resumo:
The mature dentinoenamel junction (DEJ) is viewed by some investigators and the current authors, not as a fossilized, sharp transition between enamel and dentin, but as a relatively broad structural transition zone including the mantle dentin and the inner aprismatic enamel. In this study, the DEJ structure in bovine incisors was studied with synchrotron microComputed Tomography (microCT) using small cubes cut parallel to the tooth surface. The reconstructions revealed a zone of highly variable punctate contrast between bulk dentin and enamel; the mean linear attenuation coefficients and their standard deviations demonstrated that this zone averaged less mineral than dentin or enamel but had more highly variable structure than either. The region with the punctuate contrast is, therefore, the mantle dentin. The thickness of the mantle dentin seen in a typical data set was about 30 mu m, and the mantle dentin-enamel interface deviated +/- 15 mu m from the average plane over a distance of 520 mu m. In the highest resolution data (similar to 1.5 mu m isotropic voxels, volume elements), tubules in the dentin could be discerned in the vicinity of the DEJ. Contrast sensitivity was high enough to detect differences in mineral content between near-surface and near-DEJ volumes of the enamel. Reconstructions before and after two cubes were compressed to failure revealed cracks formed only in the enamel and did not propagate across the mantle dentin, regardless of whether loading was parallel to or perpendicular to the DEJ. (C) 2007 Elsevier B.V. All rights reserved.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Synchrotron microtomography is a tool to quantify the mineralization of dental tissues as well as microhardness analysis, since they provide adequate precision and contrast sensitivity. This study evaluates synchrotron microtomography and microhardness analysis for quantifying the mineral content of bovine enamel. Fifty enamel blocks were submitted individually for 5 days to a pH-cycling model at 37 degrees C and remained in the remineralizing solution for 2 days. The blocks were treated twice daily for 1 min with NaF dentifrices (Placebo, 275, 550, 1,100 mu g F/g and Crest (R)) diluted in deionized water. Surface microhardness changes (%SMH) and mineral loss (Delta Z) were then calculated. Synchrotron microtomography was also used to measure total mineral lost (SMM). Pearson's correlation (p < 0.05) was used to determine the relationship between different methods of analysis and dose-response between treatments. Dentifrice fluoride concentration and %SMH and Delta Z were correlated (p < 0.05). There was a positive relationship (p < 0.05) when comparing SMM vs. Delta Z; a negative relationship (p < 0.05) was found for %SMH vs. SMM and %SMH vs. Delta Z. Based on the results of this study, it was possible to conclude that synchrotron microtomography provides the best spatial resolution and contrast sensitivity for quantifying mineral gradients.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Purpose: To assess visual outcomes and patient satisfaction following implantation of the Sulcoflex® multifocal intraocular lens (IOL; Rayner Intraocular Lenses Ltd., Hove, UK) in a procedure combining capsular bag lens implantation with sulcus placement of the Sulcoflex® IOL. Setting: Instituto de Oftalmologia de Assis, Assis, SP, Brazil. Methods: Cataract patients > 45 years, with hyperopia ≥ 1.50 D and potential acuity measurement ≥ 20/30 undergoing Sulcoflex® multifocal IOL implantation were included. Monocular and binocular uncorrected near and distance visual acuity (VA) were evaluated at five days, one month, and three months postoperatively. Contrast sensitivity and refraction were measured in a subset of patients three months postoperatively. Patient satisfaction was assessed one month postoperative. Results: This non-consecutive case series comprised 25 eyes of 13 patients. Eleven eyes (52%) had pre-existing retinal pathologies. Monocular distance VA improved significantly at all follow-up visits. At final follow-up, 88% of eyes had monocular uncorrected distance VA (UDVA) of at least 20/25 and 24% had monocular UDVA of 20/20. All eyes had binocular UDVA of at least 20/25, and 58% had binocular UDVA of 20/20. Monocular uncorrected near vision (UNVA) was J1 in 68% of eyes and all patients had binocular UNVA of J1. Of all eyes studied, 92% and 58% achieved a spherical equivalent within 1 D and −0.5 D, respectively. The majority of patients reported satisfaction with visual outcomes. Complications included a postoperative intraocular pressure spike in four eyes. Conclusion: The Sulcoflex® multifocal IOL improves near and distance VA in cataract patients with retinal abnormalities and good VA potential.