45 resultados para CLIP

em Repositório Institucional UNESP - Universidade Estadual Paulista "Julio de Mesquita Filho"


Relevância:

20.00% 20.00%

Publicador:

Resumo:

An efficient technique to cut polygonal meshes as a step in the geometric modeling of topographic and geological data has been developed. In boundary represented models of outcropping strata and faulted horizons polygonal meshes often intersect each other. TRICUT determines the line of intersection and re-triangulates the area of contact. Along this line the mesh is split in two or more parts which can be selected for removal. The user interaction takes place in the 3D-model space. The intersection, selection and removal are under graphic control. The visualization of outcropping geological structures in digital terrain models is improved by determining intersections against a slightly shifted terrain model. Thus, the outcrop line becomes a surface which overlaps the terrain in its initial position. The area of this overlapping surface changes with respect to the strike and dip of the structure, the morphology and the offset. Some applications of TRICUT on different real datasets are shown. TRICUT is implemented in C+ + using the Visualization Toolkit in conjunction with the RAPID and TRIANGLE libraries. The program runs under LINUX and UNIX using the MESA OpenGL library. This work gives an example of solving a complex 3D geometric problem by integrating available robust public domain software. (C) 2002 Elsevier B.V. Ltd. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objetivo: estudar as repercussões da hipertensão arterial sobre o peso e comprimento corpóreo e sobre o peso do fígado e do cérebro de recém-nascidos (RN). Métodos: foram utilizadas 82 ratas virgens da raça Wistar em idade de reprodução. Após a indução da hipertensão arterial experimental (modelo Goldblatt I: 1 rim - 1 clipe) as ratas foram sorteadas para compor os quatro grandes grupos experimentais (controle (C), manipulação (M), nefrectomia (N) e hipertensão (H). A seguir, as ratas foram distribuídas por sorteio em 8 subgrupos, sendo quatro grupos prenhes e quatro grupos não-prenhes. Após acasalamento dos quatro grupos prenhes, obtivemos com o nascimento dos recém-nascidos os seguintes grupos: RN-C, RN-M, RN-N e RN-H, respectivamente controle, manipulação, nefrectomia e hipertensão. Resultados: quanto ao peso e comprimento corpóreo dos recém-nascidos observamos que os grupos RN-N e RN-H apresentaram os menores pesos e comprimentos em relação ao seus controles. Quanto ao peso do fígado os RN-H apresentaram os menores pesos em relação aos seus controles. Conclusão: a hipertensão arterial determinou redução no peso corpóreo, no comprimento, no peso do fígado e no peso do encéfalo dos recém-nascidos.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objetivo: desenvolver o modelo experimental de hipertensão tipo Goldblatt I (1 rim - 1 clipe), em ratas, para estudar a interação entre hipertensão e prenhez. Métodos: o experimento foi dividido em 5 períodos: adaptação (2 semanas), cirúrgico (1 semana), desenvolvimento da hipertensão (6 semanas), acasalamento e estabilização da pressão arterial (6 semanas) e prenhez (3 semanas). Foram utilizadas 82 ratas virgens da raça Wistar, pesando entre 180-240 gramas e com idade entre 3 e 4 meses. As ratas foram sorteadas para compor os 4 grupos experimentais (controle, manipulação, nefrectomia e hipertensão) e estudadas em 15 momentos distintos (M1 a M15). A hipertensão foi induzida experimentalmente pela técnica de Goldblatt I (1 rim, 1 clipe), que consiste na constrição da artéria renal esquerda e nefrectomia contralateral. Posteriormente, foram realizadas medidas periódicas da pressão arterial pelo método da pletismografia de cauda (PAC). Resultados: os animais sem tratamento cirúrgico (controle) e com manipulação não apresentaram alterações na PAC durante o experimento. A nefrectomia determinou discreta elevação da PAC. Nos grupos de ratas prenhes, observou-se tendência a discreta diminuição da PAC, que se acentuou no final da prenhez. Conclusões: o modelo experimental foi adequado para o objetivo de nosso estudo, pois permitiu a obtenção de animais hipertensos.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objetivo: estudar as repercussões da hipertensão sobre o peso da placenta e índice placentário. Métodos: foram utilizadas 82 ratas virgens da linhagem Wistar em idade de reprodução. Após a indução da hipertensão arterial experimental (Modelo Goldblatt I -- 1 rim-1 clipe) as ratas foram sorteadas para compor os 4 grandes grupos experimentais (controle, manipulação, nefrectomia e hipertensão). A seguir, as ratas foram distribuídas por sorteio em 8 subgrupos, sendo quatro prenhes (P) e quatro não-prenhes. Após acasalamento, dos quatro grupos prenhes obtivemos com o nascimento dos recém-nascidos (RN) os seguintes grupos: RN-C, RN-M, RN-N e RN-H, respectivamente, controle, manipulação, nefrectomizado e hipertenso. Resultados: quanto ao peso da placenta, o do grupo RN-C foi estatisticamente maior que o de todos os demais grupos. Por outro lado, verifica-se que o peso das placentas provenientes do grupo RN-M foi maior que o dos grupos RN-N e RN-H, os quais não diferiram entre si. Os índices placentários dos grupos P-C (Md = 0,1085) e P-M (Md = 0,1110) não diferiram entre si, mas foram menores que os dos grupos P-N (Md = 0,1175) e P-H (Md = 0,1211), os quais também não diferiram entre si. Conclusões: a hipertensão e a nefrectomia unilateral determinaram redução do peso das placentas e aumento do índice placentário, evidenciando repercussões no desenvolvimento placentário e fetal.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This report presents the use of a dental implant with an anti-rotational attachment for the retention of a thumb prosthesis. A retention system was manufactured with an attachment (UCLA) screwed into the implant with a two-bar system that was cast in metallic silver palladium. A substructure made from heat-cured acrylic resin was joined to the retention system by clips to join the thumb to the finger (bar clip) in the cast with implant rejoinder. The silicone material, Silastic-MDX 44210, was used to achieve function and aesthetics. Following osseointegration, no skin problems were observed. Whilst the implant-retained digital prosthesis presented some motor limitations, it allowed the patient to return to entertainment and achieve social conviviality.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of this study was to assess the behavior and stress distribution of 3 retention systems associated with implant for facial prosthesis by using the photoelasticity method. A photoelastic model was made from the replica of the orbital region on the left side of a dry skull with two 4-mm implants fixed in the superior orbital region. Three facial prosthetic retention systems were made for this study: O'ring, bar-clip, and magnets. The set (model/retention systems/prosthesis) was placed in a polariscope, and then traction began to be applied to the retention systems. The limit values for removal of the retention system were obtained by tests performed in an EMIC Universal test machine. The results were obtained by observation during the experiments and by photographic record of the stress behavior in the photoelastic model, resulting from the traction of the retention systems. In the magnet system, a lowest formation of fringes was verified both around and between the implants; in the O'ring system, the formation of photoelastic fringes was noted between the implants in the apical region; and in the bar-clip system, there was a greater concentration of colored fringes in the regions between the implants and cervical area. Based on the results obtained, it was concluded that the retention systems produced different stress distribution characteristics that, in general, were concentrated in the area around the implants, and the highest concentration of fringes, in increasing order, occurred ill the retention systems of the magnets, O'ring, and bar-clip.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This study aimed to compare the influence of single-standing or connected implants on stress distribution in bone of mandibular overdentures by means of two-dimensional finite element analysis. Two finite element models were designed using software (ANSYS) for 2 situations: bar-clip (BC) group-model of an edentulous mandible supporting an overdenture over 2 connected implants with BC system, and o'ring (OR) group-model of an edentulous mandible supporting an overdenture over 2 single-standing implants with OR abutments. Axial loads (100 N) were applied on either central (L1) or lateral (L2) regions of the models. Stress distribution was concentrated mostly in the cortical bone surrounding the implants. When comparing the groups, BC (L1, 52.0 MPa and L2, 74.2 MPa) showed lower first principal stress values on supporting tissue than OR (L1, 78.4 MPa and L2, 76.7 MPa). Connected implants with BC attachment were more favorable on stress distribution over peri-implant-supporting tissue for both loading conditions.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of this study was to compare the stress distribution induced by posterior functional loads on conventional complete dentures and implant-retained overdentures with different attachment systems using a two-dimentional Finite Element Analysis (FEA-2D). Three models representative of edentulous mandible were constructed on AutoCAD software; Group A (control), a model of edentulous mandible supporting a complete denture; Group B, a model of edentulous mandible supporting an overdenture over two splinted implants connected with the bar-clip system; Group C, a model of edentuluos mandible supporting an overdenture over two unsplinted impants with the O-ring system. Evaluation was conducted on Ansys software, with a vertical force of 100 N applied on the mandibular left first molar. When the stress was evaluated in supporting tissues, groups B (51.0 MPa) and C (52.6 MPa) demonstrated higher stress values than group A (10.1 MPa). Within the limits of this study, it may be conclued that the use of an attachment system increased stress values; furthermore, the use of splinted implants associated with the bar-clip attachment system favoured a lower stress distribution over the supporting tissue than the unsplinted implants with an O-ring abutment to retain the manibular overdenture.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This finite element analysis compared stress distribution on complete dentures and implant-retained overdentures with different attachment systems. Four models of edentulous mandible were constructed: group A (control), complete denture; group B, overdenture retained by 2 splinted implants with bar-clip system; group C, overdenture retained by 2 unsplinted implants with o'ring system; and group D, overdenture retained by 2 splinted implants with bar-clip and 2 distally placed o'ring system. Evaluation was performed on Ansys software, with 100-N vertical load applied on central incisive teeth. The lowest maximum general stress value (in megapascal) was observed in group A (64.305) followed by groups C (119.006), D (258.650), and B (349.873). The same trend occurred it) supporting tissues with the highest stress value for cortical bone. Unsplinted implants associated with the o'ring attachment system showed the lowest maximum stress values among all overdenture groups. Furthermore, o'ring system also improved stress distribution when associated with bar-clip system.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background: The absence of an ear, which can be the result of a congenital malformation, surgical tumour resection or traumatic injury, is a significant aesthetic problem. Attachment of ear prostheses with adhesives can cause local irritation for the wearer and affect the colour of the prostheses. Use of implants in craniofacial reconstruction can improve the retention and stability of prostheses giving to patient greater comfort and security relative to adhesive attachment.Objective: The aim of this report was to present a clinical case of a mutilated patient who was rehabilitated by means of installing an ear prosthesis fixed through osseointegrated implants.Materials and methods: The patient had two implants installed in the mastoid region that were linked by a bar, and a clip-type system was used. The ear prosthesis was constructed from medical-use silicone, pigmented to match the patient's skin colour and linked to the retention system.Conclusion: The patient's rehabilitation was satisfactory from both a functional and an aesthetic point of view, making it possible for the patient to return to a normal social life and regain lost self-esteem.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The purposes of this study were to photoelastically measure the biomechanical behavior of 4 implants retaining different cantilevered bar mandibular overdenture designs and to compare a fixed partial denture (FPD). A photoelastic model of a human edentulous mandible was fabricated, which contained 4 screw-type implants (3.75 x 10 mm) embedded in the parasymphyseal area. An FPD and 3 overdenture designs with the following attachments were evaluated: 3 plastic Hader clips, 1 Hader clip with 2 posterior resilient cap attachments, and 3 ball/O-ring attachments. Vertical occlusal forces of 100 N were applied between the central incisor and unilaterally to the right and left second premolars and second molars. Stresses that developed in the supporting structure were monitored photoelastically and recorded photographically. The results showed that the anterior loading, the overdenture with 3 plastic Hader clips, displayed the largest stress concentration at the medium implant. With premolar loading, the FPD and overdenture with 3 plastic Hader clips displayed the highest stresses to the ipsilateral terminal implant. With molar loading, the overdenture with 3 ball/O-ring attachments displayed the most uniform stress distribution in the posterior edentulous ridge, with less overloading in the terminal implant. It was concluded that vertical forces applied to the bar-clip overdenture and FPD created immediate stress patterns of greater magnitude and concentration on the ipsilateral implants, whereas the ball/O-ring attachments transferred minimal stress to the implants. The increased cantilever in the FPD caused the highest stresses to the terminal implant.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background: Considering that an increasing number of patients are victims of mutilator surgical resections, these studies are important for treatment success of rehabilitation of patients presenting oronasal communication.Purpose: The aim of this study was to assess the stress distribution through photoelasticity in palatal obturator prostheses with different attachment systems for implants.Methods: Two photoelastic models were obtained from an experimental maxillary model presenting an oronasal communication. One model was fabricated without implant, and the other with 2 implants 10 mm in length inserted in the left crest. Four colorless palatal obturator prostheses were fabricated. One prosthesis presented no attachment system, whereas the remaining prostheses were adapted to 3 attachment systems. The assembly was positioned in a circular polariscope for application of axial load.Results: The results were based on photographic records of stress in the photoelastic model submitted to loading. The records revealed higher stress concentration on the bar-clip system followed by the O'ring/bar-clip and O'ring systems, respectively. A homogeneous stress distribution was observed on the photoelastic model with the mucous-supported prosthesis.Conclusions: The attachment systems generated different characteristics of stress distribution that was concentrated surrounding the implants. The bar-clip system exhibited the highest stress concentration on the alveolar crest.