9 resultados para Bow
em Repositório Institucional UNESP - Universidade Estadual Paulista "Julio de Mesquita Filho"
Resumo:
Motion of a nonrelativistic particle on a cone with a magnetic flux running through the cone axis (a flux cone) is studied. It is expressed as the motion of a particle moving on the Euclidean plane under the action of a velocity-dependent force. The probability fluid (quantum flow) associated with a particular stationary state is studied close to the singularity, demonstrating nontrivial Aharonov-Bohm effects. For example, it is shown that, near the singularity, quantum flow departs from classical flow. In the context of the hydrodynamical approach to quantum mechanics, quantum potential due to the conical singularity is determined, and the way it affects quantum flow is analyzed. It is shown that the winding number of classical orbits plays a role in the description of the quantum Bow. The connectivity of the configuration space is also discussed.
Resumo:
Este artigo tem o objetivo de descrever a pesca de subsistência das populações tradicionais de uma aldeia Ashaninka e duas Kaxinawá vivendo à beira do rio Breu. Inicialmente, foram treinados monitores para preencher fichas de coleta de dados das pescarias nas aldeias durante um ciclo anual (agosto/1995 agosto/1996). A partir desses dados realizaram-se os inventários das espécies de peixes capturadas e dos ambientes pesqueiros. A análise dos dados foi efetuada por meio de estatística descritiva e exploratória. Os resultados obtidos foram os seguintes: i) os ambientes mais procurados pelos índios foram os poços; ii) as espécies mais capturadas os mandis (35%, Pimelodidae), os bodes ou cascudos (Loricariidae), com destaque para o bode praiano (25%, Hypostomus sp.), o curimatã (9%, Prochilodus sp.) e os saburus (8%, Curimatidae), entre outros; iii) constatou-se que os arreios ou apetrechos de pesca que mais capturam peixes são o tingui (veneno), a tarrafa e o arco/flecha, respectivamente; iv) durante o verão a atividade de pesca é mais intensa; v) as medidas de esforço de pesca e os fatores associados que foram estatisticamente significativos nas predições das capturas na Reserva Indígena foram: f1 = o (número de pescadores), f2 = o (número de pescadores*tempo total das pescarias) e f3 = o [(número de pescadores*tempo total das pescarias)-(o tempo de deslocamento)] e os fatores aldeias e arreios; vi) apesar da maioria das pescarias serem realizadas a pé até os pesqueiros, as capturas são maiores quando a locomoção se dá através de canoa a remo; e vii) os pescadores mais ativos nas pescarias na Reserva Indígena foram os Kaxinawá.
Resumo:
A simple and attractive method for quantification of ascorbic acid (AA) in beers, soda, natural juices and commercial vitamin C tablets was achieved by combining Bow injection analysis and amperometric detection. An array of gold microelectrodes electrochemically modified by deposition of palladium was employed as working electrode which was almost unaffected by fouling effects. Ascorbic acid was quantified in beverages and vitamin tablets using amperometric differential measurements. This method is based on three steps involving the flow injection of: 1) the sample plus a standard addition of AA, 2) the pure sample, and 3) the enzymatically-treated sample. The enzymatic treatment was carried out with Cucumis sativus tissue, which is a rich source of ascorbate oxidase, at pH 7. The calibration plots for freshly prepared ascorbic acid standards were very linear in the concentration range of 0.18-1.8 mg L-1 with a relative standard deviation (RSD) < 1%, while for real samples the deviations were between 2.7% to 8.9%.
Resumo:
Different measurements were performed in cross-linked polyethylene (XLPE) employed as insulating material in coaxial cables that were field-aged and laboratory-aged under multi-stressing conditions at room temperature. Samples were peeled from the XLPE cable insulation in three different positions: just below the external semiconductor layer (outer layer), in the middle (middle layer) and just above the internal semiconductor layer of the cable (inner layer). The imaginary part of the electric susceptibility showed three peaks that obey the Dissado-Hill model. For laboratory-aged XLPE samples peeled from the inner and from the middle positions the peak at very low frequency region increased while in samples from the outer position a quasi-DC conduction process was observed. In medium frequency range a broadening of the peak was observed for all samples. Viscoelastic properties determined through dynamic mechanical analysis suggested that the aging generates processes that promoted changes of the crystallinity and the cross-linking degrees of the polymer. Fourier transform infrared spectroscopy (FTIR) measurements revealed an increase of oxidation products (esters), evidence of polar residues of the bow-tie tree and the presence of cross-linking by-products (acetophenone). Optical and scanning electronic microscope (SEM) measurements in aged samples revealed the existence of voids and bow-tie trees that were formed during aging in the middle region of the cable.
Resumo:
This study evaluated the Eucalyptus grandis drying defects acting on boards diametrical position and on log steaming. Half of the logs, with diameter from 20 to <25, 25 to <30 and 30 to <35cm, were steamed during 20 hours at 90°C of temperature. Subsequently, the logs (control and steamed) were sawn. The boards were dried in the dry-kiln pilot and the resulting defects from the drying process were measured. The results indicate that: (1) the boards coming from control logs presented different magnitude defects in function of the diametrical position. The split and spring to increase in direction to pith, the bow to increase in direction to bark and cupping were bigger in intermediary boards; (2) the boards coming from steamed logs presented a reduction from drying defects in function of logs diameter and its more homogeneous index in the pith-bark direction.
Resumo:
Pós-graduação em Agronomia (Ciência do Solo) - FCAV
Resumo:
Purpose: The aim of this study was to compare occlusal plane angulation measured in two different types of semi-adjustable articulators with that obtained on the lateral cephalometric radiograph. Materials and Methods: 20 patients due to undergo orthognathic surgery had dental casts mounted in two different types of semi-adjustable articulators through face bow transfer from the position of the maxilla and occlusal recording to the mandible. After mounting, the inclination of the occlusal plane in the articulators was measured and compared with the inclination measured at on both articulators and compared with the inclination measured on the lateral cephalometric radiographs and between the articulators themselves. The results obtained werestatistically analyzed. Results: Mean angulation values for the Bio Art (7.55º) and Kavo (-5.70º) articulators differ by 13.25º, which is statistically significant (p=0.00). When individually compared to the lateral cephalometric radiograph (5.075º), the Bio Art articulator showed more similar angulation values, with a difference of 2.475º, while the Kavo articulator presented a difference of 10.775º. Conclusion: Neither of the models of semi-adjustable articulators accurately reproduced the inclination of the maxillary occlusal plane of patients with dentofacial deformities; the difference between the two articulators tested and the lateral cephalometric radiograph was lower for the Bio Art than for the Kavo articulator.
Resumo:
This report shows the resolution of a case study whose aim was promote the aesthetic and functional rehabilitation of upper left hemi-arch over endosseous and needle implant prostheses. To improve the position of the needle implants, we performed the bucco-palatal bending of needles splinting them with composite resin; we removed the screwed implant prosthesis in the regions of the premolars (24 and 25) and molar (26). The mini-abutments of the last two implants were replaced, and in the first premolar and canine, we used cemented abutments due to implant angulation having planned soldering because of implant size and contact with one needle implant that could interfere with intimate contact bone/implant damaging biomechanics. Pick-up impressions were performed with an open tray, using a retractor cord in the needle implants and respective transfer copings. Therefore, models were related on semi-adjustable articulator after a face-bow recording and interocclusal indexes. After working cast fabrication and try-in of infra-structures, these were adjusted and related into the articulator again. Then, after ceramic build-up, adjustments, finishing, and torque, chemically-activated resin cement was applied on units 21 to 24. At the end of the case, we concluded that a good aesthetic and functional rehabilitation depends on thorough knowledge of techniques for each clinical situation.
Resumo:
It presented the main features so that the wax plan can be conveniently filling the aesthetic and functional requirement of a denture. The steps of face bow mounting and wax plan transfer form the mouth to the articulator, considering the necessary requirement for this purpose are shown. This sequence aims to instruct and warn those who work with dentures about the needs of using face bows for correct reproduction of the models positioning in the articulator