66 resultados para Biomechanical analysis
em Repositório Institucional UNESP - Universidade Estadual Paulista "Julio de Mesquita Filho"
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
The purpose of this study was to evaluate commercially pure titanium implant surfaces modified by laser beam (LS) and LS associated with sodium silicate (SS) deposition, and compare them with machined surface (MS) and dual acid-etching surfaces (AS) modified. Topographic characterization was performed by scanning electron microscopy-X-ray energy dispersive spectroscopy (SEM-EDX), and by mean roughness measurement before surgery. Thirty rabbits received 60 implants in their right and left tibias. One implant of each surface in each tibia. The implants were removed by reverse torque for vivo biomechanical analysis at 30, 60, and 90 days postoperative. In addition, the surface of the implants removed at 30 days postoperative was analyzed by SEM-EDX. The topographic characterization showed differences between the analyzed surfaces, and the mean roughness values of LS and SS were statistically higher than AS and MS. At 30 days, values removal torque LS and SS groups showed a statistically significant difference (p < 0.05) when compared with MS and AS. At 60 days, groups LS and SS showed statistically significant difference (p < 0.05) when compared with MS. At 90 days, only group SS presented statistically higher (p < 0.05) in comparison with MS. The authors can conclude that physical chemistry properties and topographical of LS and SS implants increases bone-implant interaction and provides higher degree of osseointegration when compared with MS and AS. © 2012 Wiley Periodicals, Inc.
Resumo:
Surface and biomechanical analysis of titanium implant surfaces modified by laser beam with and without hydroxyapatite. Titanium implants with 3 different surfaces were inserted into the tibias of 30 rabbits: group I (GI) machined surface (control group), group II irradiated with laser (GII), and group III irradiated with laser and hydroxyapatite coating applied-biomimetic method (GIII). Topographical analysis with scanning electron microscopy was made before surgery in the tibia. These rabbits were distributed into 2 periods of observation: 4 and 8 weeks postsurgery, after which biomechanical analysis (removal torque) was conducted. Statistical analysis used the Student-Newman-Keuls method. Surface showed roughness in GII and GIII. Biomechanical analysis demonstrated values with significant differences in GII and GIII. Titanium implants modified by laser irradiation can increase osseointegration during the initial phase.
Resumo:
OBJETIVO: avaliar a influência do alcoolismo crônico experimental na morfologia e biomecânica da artéria aorta de ratos. MÉTODOS:ratos Wistar foram divididos em dois grupos de 22 animais. Grupo alcoolista: os ratos receberam água com concentração crescente de etanol e ração ad libitum durante 6 meses. Grupo controle: os animais receberam água e ração ad libitum pelo mesmo período. Os animais foram sacrificados com overdose de pentobarbital e as aortas abdominais foram excisadas para realização de histologia (hematoxilina-eosina, tricrômio de Masson, Calleja, Picrosirius red), histomorfometria e avaliação biomecânica (carga máxima, alongamento na carga máxima, limite de proporcionalidade, alongamento no limite de proporcionalidade e coeficiente de rigidez). RESULTADOS: A histologia e a histomorfometria não mostraram diferenças significantes na morfologia da aorta em ambos os grupos. A avaliação biomecânica mostrou aumento do alongamento no limite de proporcionalidade no grupo alcoolista (p<0.05). CONCLUSÃO: o alcoolismo crônico experimental não provocou alterações morfológicas na parede da aorta, mas causou aumento da sua elasticidade, sem modificar as outras propriedades mecânicas avaliadas.
Resumo:
Objectives: the purpose of this study was to evaluate the surfaces of commercially pure titanium (cpTi) implants surface modified by laser beam (LS), by laser beam associated with sodium silicate deposition (SS) and compare them with surfaces modified by dual-acid etched (AS) and with machined surface (MS). Methods: thirty rabbits received two implants each (one for each tibia). After 30, 60 and 90 days postoperative, the implants were removed by reverse torque for biomechanical analysis and surfaces were analyzed by scanning electron microscopy (SEM) and X-ray energy dispersive spectroscopy (EDS). Results: the mean values of reverse torque at 30, 60 and 90 days postoperative were respectively 24.60, 43.60 e 60.40 N.cm to MS, 43.00, 68.20 e 63.80 N.cm to AS group, 59.80, 76.60 e 78.00 N.cm to LS group and 63.00, 75.40 e 76.60 N.cm to SS group. At 30 days, LS and SS groups showed statistically significant difference (p<0.05) compared to the other groups. At 60 days, LS and SS groups showed statistically significant difference (p<0.05) when compared to MS. Conclusions: it was concluded that SL and SS implants' biomechanical and topographical properties increased bone-implant interaction when compared to the AS and MS implants.
Resumo:
Os AINH (Antiinflamatórios não hormonais) são agentes utilizados na prática clínica que interferem no processo inflamatório pela inibição da síntese de prostaglandinas e tromboxanos. Alguns trabalhos experimentais investigaram sua ação no processo de consolidação de fraturas, por meio de estudos clínicos e histológicos, sendo escassas as análises biomecânicas. Nesse estudo foram utilizados 20 ratos da linhagem Wistar, divididos aleatoriamente em dois grupos iguais: grupo A (controle) e grupo B (tratado com diclofenaco sódico). em ambos os grupos foram realizadas fraturas abertas, após perfuração, na tíbia direita. A administração da droga foi via intramuscular, dose única diária, por 28 dias. Os animais foram pesados semanalmente. Após o sacrifício as tíbias foram dissecadas, pesadas e submetidas a ensaio biomecânico de flexão analisando-se carga máxima, deformação e coeficiente de rigidez. Observou-se que no grupo tratado com AINH não houve aumento do peso corpóreo a partir da segunda semana e as tíbias fraturadas foram mais pesadas. Neste grupo o calo ósseo suportou menor carga máxima, apresentando maior deformação e menor coeficiente de rigidez. Nos animais tratados, o osso não fraturado também se mostrou menos rígido. Concluiu-se, nas condições estudadas, que o DS alterou o processo de consolidação e o metabolismo ósseo, levando a retardo na maturação do calo e menor rigidez do osso intacto, respectivamente.
Resumo:
The aim of this study was to evaluate implants installed with compromised primary stability associated or not with polylactide and polyglycolide copolymer (PLA/PGA). Two 0.4-mm overdrilled defects (3 mm in diameter and 6 mm long) were produced in the right tibia of 25 rabbits. Half of the defects were left untreated, and the other half was filled with PLA/PGA. Implants of 2.6 mm in diameter and 6 mm long were placed into all defects. Animals were killed at 5, 15, 40, and 60 postoperative days, and biomechanical analysis (torque-reverse), histomorphometry, and immunohistochemistry (osteoprotegerin, receptor activator of NFJB ligand [RANKL], osteocalcin, and collagen-1 [ COL- I] staining) were performed. All the implants achieved osseointegration. There were no statistically significant differences in the torque-reverse and in linear contact extension between bone tissue and implant surface and no statistically significant difference in osteoprotegerin, RANKL, osteocalcin, and collagen-1 expression between the studied groups in all studied periods (P > 0.05). We can conclude that osseointegration can occur in compromised primary implant stability situations, and the addition of PLA/PGA did not improve the osseointegration process in this experimental model.
Resumo:
This research describes the application of a scientific and technological model of Ergonomics in the design of pre-school furniture. The constant presence of the desk in early education and its influence in the relationship between the user and his educational environment determined the necessity of this project. The pre-school desk was considered as a work station, where the joint aspects of education and child anthropometry substantiate the problem. The review of the Historical application of Ergonomics in the Design of children's products consolidated the importance of this report. The development of ergonomic research, characterised by investigations of the Brazilian child's Anthropometry Data and Biomechanical Features, resulted in dimensional parameters of the user and physical characteristics of the present furniture. These elements, together with a comprehension of activities and needs in the pre-school, were connected with aspects of bibliographical revision to result in a series of recomendations for design. Through the methods of Ergonomic Design, a new proposal for the pre-school desk was developed, denominated Mobipresc 3.6.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Pós-graduação em Ciência Animal - FMVA
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Pós-graduação em Odontologia - FOA