104 resultados para BRANCHED POLYETHYLENES

em Repositório Institucional UNESP - Universidade Estadual Paulista "Julio de Mesquita Filho"


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Branched polyethylene/high-density polyethylene blends (BPE/HDPE) with a wide range of molecular weights, melt flow indexes (MFI), and intrinsic viscosity were prepared using the homogeneous binary catalyst system composed by Ni(alpha-diimine)Cl-2 (1) (alpha-diimine = 1,4-bis(2,6-diisopropylphenyl)-acenaphthenediimine) and {Tp(Ms*)} TiCl3 (2) (Tp(Ms*)=hydridobis(3-mesitylpyrazol-1-yl)(5-mesityl-pyrazol-1-yl)) activated with MAO and/or TIBA in hexane at two different polymerization temperatures (30 and 55 degreesC) and by varying the nickel loading molar fraction (x(Ni)). At all Temperatures, a non-linear correlation between the x(Ni) and the productivity was observed, suggesting the occurrence of a synergistic effect between the nickel and the titanium catalyst precursors, which is more pronounced at 55 degreesC. The molecular weight of the BPE/HDPE blends considerably decreases with increasing Al/M molar ratio. The melt flow indexes (MFI) and intrinsic viscosities (eta) are strongly affected by x(Ni), but the melting temperatures are nearly constant, 132 +/- 3 degreesC. Dynamic mechanical thermal analysis (DMTA) shows the formation of different polymeric materials where the stiffness vanes according, to the x(Ni) and temperature used in the polymerization reaction. The surface morphology of the BPE/HDPE blends studied by scanning electron microscopy (SEM) revealed a low miscibility between the PE phases resulting in the formation of a sandwich structure after etching with o-xylene.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Calcium binding and charge distribution on highly branched and linear sulfated L-galactans from ascidians have been studied using a metallochromic indicator and conductimetric titrations. The distance between charged groups of the linear and highly branched galactans does not vary despite their marked differences in sulfate/total sugar molar ratios. These results indicate that the sulfated L-galactose units are concentrated in the central polysaccharide core and not intercalated among non-sulfated units. This inference is consistent with the chemical studies of these galactans. Surprisingly, calcium affinity increases with increasing amounts of non-sulfated sugar branches in the molecule. Thus, calcium binding in these polymers is not a simple function of availability of anion binding sites but a more complex calcium-polysaccharide interaction. (C) 1998 Elsevier B.V. Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The present study evaluated the origin, distribution and ramification of the radial nerves were studied in 30 adult domestic cats. The sample included 15 females and 15 males of unknown breed. The specimens were fixed in 10% formaldehyde solution. The radial nerve showed many fascicles from the origin also your ramification in superficial and deep branches. Radial nerves were observed to originate, in 16 cases (26.7%), from the ventral branch of the sixth cervical spinal nerve; in 60 cases (100%), from the ventral branch of the seventh cervical spinal nerve; in 60 cases (100%), from the ventral branch of the eight cervical nerve and in 60 cases (100%), from the ventral branch of the first thoracic nerve. The radial nerves branched out, in all of the animals studied (100.0%), to the tensor fasciae antebrachii, long, accessory, medial and lateral heads of the triceps branchii and anconeus muscles. The radial nerve emits of 14 to 25 nervous branches in this region. However, the branch of the sixth cervical spinal nerve and the nervous fascicles reveal significant differences (p <= 0.05), respectively, in or with relation to sex of the animals and the studied region.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Dendritic nucleic acids are highly branched and ordered molecular structures, possessing numerous single-stranded oligonucleotide arms, which hold great promise for enhancing the sensitivity of DNA biosensors. This article evaluates the interfacial behavior and redox activity of nucleic acid dendrimers at carbon paste electrodes, in comparison to DNA. Factors influencing the adsorption behavior, including the adsorption potential and time, solution conditions, or dendrimer concentration, are explored. The strong adsorption at the anodically pretreated carbon surface is exploited for an effective preconcentration step prior to the chronopotentiometric measurement of the surface species. Coupled with the numerous guanine oxidation sites, such stripping protocol offers remarkably low detection limits (e.g., 3 pM or 2.4 femtomole of the I-layer dendrimer following a 15 min accumulation). The new observations bear important implications upon future biosensing applications of nucleic dendrimers.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Based on analyses of high-speed video recordings of cloud-to-ground lightning in Brazil and the USA, the characteristics of positive cloud-to-ground (+CG) leaders are presented. The high frame rates permitted the average, 2-dimensional speeds of development along the paths of the channels to be resolved with good accuracy. The values range from 0.3 to 6.0 x 10(5) ms(-1) with a mean of 2.7 x 10(5) ms(-1). Contrary to what is usually assumed, downward +CG leader speeds are similar to downward -CG leader speeds. Our observations also show that the speeds tend to increase by a factor of 1.1 to 6.5 as they approach the ground. The presence of short duration, recoil leaders (RLs) during the development of positive leaders reveal a highly branched structure that is not usually recorded when using conventional photographic and video cameras. The existence of the RLs may help to explain observations of UHF-VHF radiation during the development of +CG flashes.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Introduction: So far the only endovascular option to treat patients with thoraco abdominal aortic aneurysms is the deployment of branched grafts. We describe a technique consisting of the deployment of standard off-the- shelf grafts to treat urgent cases.Material and Methods: The sandwich technique consists of the deployment of ViaBahn chimney grafts in combination with standard thoracic and abdominal aortic stent grafts. The chimney grafts are deployed using a transbrachial and transaxillary access. These coaxial grafts are placed inside the thoracic tube graft. After deployment of the infrarenal bifurcated abdominal graft a bridging stent-a short tube graft is positioned inside the thoracic graft further stabilizing the chimney grafts.Results: 5 patients with symptomatic thoraco abdominal aneurysms were treated. There was one Type I endoleak that resolved after 2 months. In all patients 3 stentgrafts had to be used When possible all visceral and renal branches were revascularized. A total number of 17 arteries were reconnected with covered branches. During follow up we lost one target vessel the right renal artery.Conclusion: The sandwich technique in combination with chimney grafts permits a total endovascular exclusion of thoraco abdominal aortic aneurysms. In all cases off-the shelf products and grafts could be used. The number of patients treated so far is still too small to draw further more robust conclusions with regard to long term performance and durability. (C) 2010 European Society for Vascular Surgery. Published by Elsevier Ltd. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background: Significant morbidity and mortality are related to conventional aortic replacement surgery. Endovascular debranching techniques, fenestrated or branched endografts are time consuming and costly.Objective: We alternatively propose to use endovascular approach with parallel grafts for debranching of aortic arch.Methods: Under general anesthesia, 12 F sheaths were inserted in the femoral, axillary and common carotid arteries for vascular accesses. ViaBahn grafts 10 - 15 cm in length were placed into the aortic arch from right common carotid, left common carotid and left axillary arteries, until the tip of each graft reached into the ascending aorta. Through one femoral artery, the aortic stent-graft was positioned and delivered. Soon after, the parallel grafts were sequentially delivered. Self-spanding Wallstents(R) were used for parallel grafts reinforcement. Ballooning was routinely used for parallel grafts and rarely for aortic graft.Results: This technique was used in 2 cases. The first one was a lady with 72 years old, with an aortic retrograde dissection from left subclavian artery and involving remaining arch branches. Through right common carotid artery a stent-graft was placed in the ascending aorta and through the left common carotid artery a ViaBahn was inserted parallel to the former. A thoracic endograft then covered all the aortic arch dissection extending into the ascending aorta close to the sinu-tubular junction. The second case was a 82 year old male patient with a 7 cm aortic arch aneurysm. Through both common carotid arteries ViaBahn grafts were introduced and positioned into the ascending aorta. Soon after, the deployment of the thoracic stent graft covered all parallel grafts of the aortic arch, excluding the aneurysm. Both cases did not have neurologic or cardiac complications and were discharged 10 days after the procedure.Conclusions: This technique may be a good minimal invasive off-the-shelf technical option for aortic arch "debranching". More data and further improvements are required before this promising technique can be widely advocated. (C) 2011 European Society for Vascular Surgery. Published by Elsevier Ltd. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BackgroundDetection and quantification of hepatitis C virus (HCV) RNA is integral to diagnostic and therapeutic regimens. All molecular assays target the viral 5'-noncoding region (59-NCR), and all show genotype-dependent variation of sensitivities and viral load results. Non-western HCV genotypes have been under-represented in evaluation studies. An alternative diagnostic target region within the HCV genome could facilitate a new generation of assays.Methods and FindingsIn this study we determined by de novo sequencing that the 3'-X-tail element, characterized significantly later than the rest of the genome, is highly conserved across genotypes. To prove its clinical utility as a molecular diagnostic target, a prototype qualitative and quantitative test was developed and evaluated multicentrically on a large and complete panel of 725 clinical plasma samples, covering HCV genotypes 1-6, from four continents (Germany, UK, Brazil, South Africa, Singapore). To our knowledge, this is the most diversified and comprehensive panel of clinical and genotype specimens used in HCV nucleic acid testing (NAT) validation to date. The lower limit of detection (LOD) was 18.4 IU/ml (95% confidence interval, 15.3-24.1 IU/ml), suggesting applicability in donor blood screening. The upper LOD exceeded 10(-9) IU/ml, facilitating viral load monitoring within a wide dynamic range. In 598 genotyped samples, quantified by Bayer VERSANT 3.0 branched DNA (bDNA), X-tail-based viral loads were highly concordant with bDNA for all genotypes. Correlation coefficients between bDNA and X-tail NAT, for genotypes 1-6, were: 0.92, 0.85, 0.95, 0.91, 0.95, and 0.96, respectively; X-tail-based viral loads deviated by more than 0.5 log10 from 5'-NCR-based viral loads in only 12% of samples (maximum deviation, 0.85 log10). The successful introduction of X-tail NAT in a Brazilian laboratory confirmed the practical stability and robustness of the X-tail-based protocol. The assay was implemented at low reaction costs (US$8.70 per sample), short turnover times (2.5 h for up to 96 samples), and without technical difficulties.ConclusionThis study indicates a way to fundamentally improve HCV viral load monitoring and infection screening. Our prototype assay can serve as a template for a new generation of viral load assays. Additionally, to our knowledge this study provides the first open protocol to permit industry-grade HCV detection and quantification in resource-limited settings.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJETIVO: Avaliar a ligação entre músculos oculares extrínsecos e esferas de polietileno poroso usando um bioadesivo. MÉTODOS: Estudo experimental envolvendo 8 coelhos albinos submetidos a enucleação do olho direto com colocação de implante esférico de polietileno poroso de 12 mm de diâmetro unido aos músculos oculares extrínsecos por meio do bioadesivo 2-octil-cianoacrilato. Noventa dias após a cirurgia os animais foram sacrificados e o conteúdo orbitário removido. em 4 animais foi realizado estudo biomecânico, avaliando-se a força de ruptura entre a musculatura e a esfera (grupo implante) e entre a musculatura e a esclera nos olhos contralaterais (grupo controle). Nos outros 4 animais foi realizada análise histológica. RESULTADO: A avaliação biomecânica revelou que a força de ruptura entre esfera-músculo e esclera-músculo foram semelhantes quando se usa o adesivo de cianoacrilato. O exame histológico mostrou reação fibrovascular no local da adesão entre a musculatura e a esfera, sem efeitos deletérios aos tecidos. Ao redor dos implantes foi possível observar pseudocápsula e no interior, neovasos e tecido fibrovascular preenchendo os espaços entre os grânulos do polietileno. CONCLUSÃO: O adesivo 2-octil-cianoacrilato mantém boa força de adesão na união entre os músculos e as esferas de polietileno poroso, com redução do tempo cirúrgico e sem efeitos deletérios aos tecidos orbitais. Desta forma, deve-se considerar o uso do bioadesivo na reconstrução da cavidade anoftálmica.