6 resultados para BOR

em Repositório Institucional UNESP - Universidade Estadual Paulista "Julio de Mesquita Filho"


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Com objetivo de avaliar as estratégias de polinização de espécies de Bignoniaceae, foram estudados a biologia floral e os visitantes florais de cinco espécies, três arbustivas do cerrado (Arrabidaea brachypoda (DC.) Bor., Jacaranda decurrens Cham. e Jacaranda oxyphylla Cham.) e duas lianas da orla da floresta estacional semidecidual (Arrabidaea samydoides (Cham.) Sandw. e Arrabidaea triplinervia H. Baill.), na região de Botucatu (22º52'20 S e 48(0)26'37 W), estado de São Paulo, sudeste do Brasil. Os períodos de florescimento, principalmente entre espécies do mesmo habitat, apresentaram sobreposição parcial. Observou-se que as cinco espécies são alogâmicas funcionais, melitófilas, nototríbicas, polinizadas principalmente por abelhas grandes de língua comprida. Algumas abelhas coletoras de pólen de tamanho médio e pequeno atuaram como polinizadoras ocasionais, enquanto outros visitantes foram pilhadores. Cada uma das Bignoniaceae apresentou um conjunto particular de polinizadores havendo apenas duas espécies comuns a mais de uma delas. Não houve partilha de polinizadores mesmo entre bignoniáceas que, no mesmo habitat, apresentaram períodos de florescimento simultâneo.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Introduction  Branchio-oto-renal (BOR) syndrome is an autosomal-dominant genetic condition with high penetrance and variable expressivity, with an estimated prevalence of 1 in 40,000. Approximately 40% of the patients with the syndrome have mutations in the gene EYA1, located at chromosomal region 8q13.3, and 5% have mutations in the gene SIX5 in chromosome region 19q13. The phenotype of this syndrome is characterized by preauricular fistulas; structural malformations of the external, middle, and inner ears; branchial fistulas; renal disorders; cleft palate; and variable type and degree of hearing loss. Aim  Hearing loss is part of BOR syndrome phenotype. The aim of this study was to present a literature review on the anatomical aspects and audiological profile of BOR syndrome. Data Synthesis  Thirty-four studies were selected for analysis. Some aspects when specifying the phenotype of BOR syndrome are controversial, especially those issues related to the audiological profile in which there was variability on auditory standard, hearing loss progression, and type and degree of the hearing loss. Mixed loss was the most common type of hearing loss among the studies; however, there was no consensus among studies regarding the degree of the hearing loss.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The present study aimed to assess the influence of curing distance on the loss of irradiance and power density of four curing light devices. The behavior in terms of power density of four different dental curing devices was analyzed (Valo, Elipar 2, Radii-Cal, and Optilux-401) using three different distances of photopolymerization (0 mm, 4 mm, and 8 mm). All devices had their power density measured using a MARC simulator. Ten measurements were made per device at each distance. The total amount of energy delivered and the required curing time to achieve 16 J/cm2 of energy was also calculated. Data were statistically analyzed with one-way analysis of variance and Tukey’s tests (p < 0.05). The curing distance significantly interfered with the loss of power density for all curing light devices, with the farthest distance generating the lowest power density and consequently the longer time to achieve an energy density of 16 J/cm2 (p < 0.01). Comparison of devices showed that Valo, in extra power mode, showed the best results at all distances, followed by Valo in high power mode, Valo in standard mode, Elipar 2, Radii-Cal, and Optilux-401 halogen lamp (p < 0.01). These findings indicate that all curing lights induced a significant loss of irradiance and total energy when the light was emitted farther from the probe. The Valo device in extra power mode showed the highest power density and the shortest time to achieve an energy density of 16 J/cm2 at all curing distances.