400 resultados para BIOPSY

em Repositório Institucional UNESP - Universidade Estadual Paulista "Julio de Mesquita Filho"


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of the present study was to examine the impact of polymorphisms in prostate-specific antigen (PSA) and androgen-related genes (AR, CYP17, and CYP19) on prostate cancer (PCa) risk in selected high-risk patients who underwent prostate biopsy. Blood samples and prostate tissues were obtained for DNA analysis. Single-nucleotide polymorphisms in the 50-untranslated regions (UTRs) of the PSA (substitution A > G at position -158) and CYP17 (substitution T > C at 50-UTR) genes were detected by polymerase chain reaction (PCR)-restriction fragment length polymorphism assays. The CAG and TTTA repeats in the AR and CYP19 genes, respectively, were genotyped by PCR-based GeneScan analysis. Patients with the GG genotype of the PSA gene had a higher risk of PCa than those with the AG or AA genotype (OR = 3.79, p = 0.00138). The AA genotype was associated with lower PSA levels (6.44 +/- 1.64 ng/mL) compared with genotypes having at least one G allele (10.44 +/- 10.06 ng/mL) (p = 0.0687, 95% CI - 0.3146 to 8.315, unpaired t-test). The multivariate analysis confirmed the association between PSA levels and PSA genotypes (AA vs. AG+GG; chi(2) = 0.0482) and CYP19 (short alleles homozygous vs. at least one long allele; chi(2) = 0.0110) genotypes. Genetic instability at the AR locus leading to somatic mosaicism was detected in one PCa patient by comparing the length of AR CAG repeats in matched peripheral blood and prostate biopsy cores. Taken together, these findings suggest that the PSA genotype should be a clinically relevant biomarker to predict the PCa risk.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: We present our experience in a series of 17 consecutive pediatric patients submitted to retroperitoneal laparoscopic renal biopsy. MATERIALS and METHODS: Retroperitoneal laparoscopic renal biopsy (LRB) was performed in 5 boys and 12 girls. Mean age was 8.1 years and age range from 2 to 12. Two or three trocars were used to expose the inferior pole of the kidney, remove enough cortical parenchymal specimen and fulgurate the biopsy site. Assessment included surgical time, estimated blood loss, hospitalization period, analgesia requirements, complications and number of glomeruli present in the specimen. RESULTS: LRB was successfully performed in all 15 patients (88%). In two cases, LRB was not possible to be performed. One patient was converted to a transperitoneal laparoscopy due to tear in the peritoneum. The other patient had had previous abdominal surgery and, during retroperitoneal balloon dilation, the peritoneum was opened and the open biopsy was performed. A third patient had postoperatively a perirenal hematoma, which was solved spontaneously. Complication rate was 17.6% (3/17 cases). Mean operative time was 65 minutes, while mean estimated blood loss was 52 mL, mean hospital stay was 2.2 days and mean analgesic requirement was 100 mg of tramadol. The mean number of glomeruli present in the specimen was 60. CONCLUSION: Retroperitoneal laparoscopic renal biopsy in children is a simple, safe. Bleeding is still the most common complication. However, direct vision usually allows a safe control of this drawback. In our institution, laparoscopic approach is the chosen procedure in pediatric patients older than one - year - old.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents a method for the quantification of cellular rejection in endomyocardial biopsies of patients submitted to heart transplant. The model is based on automatic multilevel thresholding, which employs histogram quantification techniques, histogram slope percentage analysis and the calculation of maximum entropy. The structures were quantified with the aid of the multi-scale fractal dimension and lacunarity for the identification of behavior patterns in myocardial cellular rejection in order to determine the most adequate treatment for each case.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Testicular biopsy has been a complementary technique for clinical and research purposes to evaluate reproductive function in males. However, hemorrhage, inflammation, degeneration, and adhesion are factors that might limit the use of this procedure. In order to minimize these potential problems, fibrin glue derived from snake venom, a tissue adhesive with sealing, hemostatic, and healing properties, was used in conjunction with bilateral testicular biopsy with the Tru-Cut needle and was compared with a more conventional technique that uses nylon suture. Thirty mature rams were randomly assigned to three groups of 10 animals each, as follows: nonsurgical control group (no scrotal surgery, or biopsy); biopsy + glue group (fibrin glue on puncture sites and skin incisions) and biopsy + suture group (compression with swab on puncture sites and suturing of skin incision). The surgeries of the rams in the biopsy groups were performed on the same day, which was designated Day 0 for all three groups. Data of scrotal circumference, number of spermatozoa per ejaculum, percentage of morphologically abnormal spermatozoa, spermatozoa motility, and serum testosterone concentrations from Days -7, 20, 40, 60, 80 and 100 were evaluated. There were no significant differences between groups within days for any of the parameters evaluated. In conclusion, the testicular biopsy procedure using the Tru-Cut needle in conjunction with conventional nylon suture or the more novel fibrin glue in rams did not affect any of the parameters of testicular function evaluated in this study and was shown to be relatively simple, safe and efficient. (C) 2002 Published by Elsevier B.V. B.V.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Neoplastic diseases are typically diagnosed by biopsy and histopathological evaluation. The pathology report is key in determining prognosis, therapeutic decisions, and overall case management and therefore requires diagnostic accuracy, completeness, and clarity. Successful management relies on collaboration between clinical veterinarians, oncologists, and pathologists. To date there has been no standardized approach or guideline for the submission, trimming, margin evaluation, or reporting of neoplastic biopsy specimens in veterinary medicine. To address this issue, a committee consisting of veterinary pathologists and oncologists was established under the auspices of the American College of Veterinary Pathologists Oncology Committee. These consensus guidelines were subsequently reviewed and endorsed by a large international group of veterinary pathologists. These recommended guidelines are not mandated but rather exist to help clinicians and veterinary pathologists optimally handle neoplastic biopsy samples. Many of these guidelines represent the collective experience of the committee members and consensus group when assessing neoplastic lesions from veterinary patients but have not met the rigors of definitive scientific study and investigation. These questions of technique, analysis, and evaluation should be put through formal scrutiny in rigorous clinical studies in the near future so that more definitive guidelines can be derived.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Sequelae due to testicular biopsy such as hemorrhage, adhesion and fibrosis may be limiting factors to the use of this surgical procedure. Fibrin glue (FG) derived from snake venom was used to minimize these sequelae, as well as to evaluate its healing property in tunica vaginalis and scrotal skin of rams. Applicability of fibrin glue derived from snake venom was tested in different tissues of other animals such as in sciatic nerve and colon of rats and skin of rabbits. In the present study, 30 healthy adult rams were used. They were divided into 3 groups of 10 animals each as follows: G1: fibrin glue group (application of fibrin glue on puncture sites and skin incisions after bilateral testicular biopsy with a Tru-Cut needle); G2: swab/nylon group (hemostasis by compression with a swab on puncture sites and skin suturing with nylon after biopsy) and G3: control group (the animals were not subjected either to biopsy or to surgery). On the 20th day after biopsy, the presence of adhesion strands between the sites of skin incision and testicle was evaluated by palpation Adhesion strands were found in three testicles (15%) in G1 and in two testicles (10%) in G2. One hundred days after biopsy, orchiectomy was carried out and the material collected was assessed for subcutaneous (SC) and/or tunica vaginalis adhesions. G3 did not present any abnormality. Groups G1 and G2 presented four testicles each (20%) with adhesion between the tunics at biopsy site. On the other hand, subcutaneous adhesions were found once (5%) in G1 and three times (15%) in G2. Fibrin glue showed to be of easy application, required short postoperative monitoring, presented fast and good-quality healing property and tended to reduce formation of subcutaneous adhesion.