191 resultados para BEAM DEPOSITION
em Repositório Institucional UNESP - Universidade Estadual Paulista "Julio de Mesquita Filho"
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Objectives: The purpose of this study was to evaluate the surfaces of commercially pure titanium (cp Ti) implants modified by laser beam (LS), without and with hydroxyapatite deposition by the biomimetic method (HAB), without (HAB) and with thermal treatment (HABT), and compare them with implants with surfaces modified by acid treatment (AS) and with machined surfaces (MS), employing topographical and biomechanics analysis. Methods: Forty-five rabbits received 75 implants. After 30, 60, and 90 days, the implants were removed by reverse torque and the surfaces were topographically analyzed. Results: At 30 days, statistically significant difference (P < 0.05) was observed among all the surfaces and the MS, between HAB/HABT and AS and between HAB and LS. At 60 days, the reverse torque of LS, HAB, HABT, and AS differed significantly from MS. At 90 days, difference was observed between HAB and MS. The microtopographic analysis revealed statistical difference between the roughness of LS, HAB, and HABT when compared with AS and MS. Conclusions: It was concluded that the implants LS, HAB, and HABT presented physicochemical and topographical properties superior to those of AS and MS and favored the osseointegration process in the shorter periods. In addition, HAB showed the best results when compared with other surfaces. © 2012 John Wiley & Sons A/S.
Resumo:
Purpose: Considering the potential of the association between laser ablation and smaller scale hydroxyapatite (HA) coatings to create a stable and bioactive surface on titanium dental implants, the aim of the present study was to determine, by the removal torque test, the effects of a surface treatment created by laser-ablation (Nd:YAG) and, later, thin deposition of HA particles by a chemical process, compared to implants with only laser-ablation and implants with machined surfaces.Materials and Methods: Forty-eight rabbits received I implant by tibia of the following surfaces: machined surface (MS), laser-modified surface (LMS), and biomimetic hydroxiapatite coated surface (HA). After 4, 8, and 12 weeks of healing, the removal torque was measured by a torque gauge. The surfaces studied were analyzed according to their topography, chemical composition, and roughness.Results: Average removal torque in each period was 23.28, 24.0, and 33.85 Ncm to MS, 33.0, 39.87, and 54.57 Ncm to LMS, and 55.42, 63.71 and 64.0 Ncm to HA. The difference was statistically significant (P < .05) between the LMS-MS and HA-MS surfaces in all periods of evaluation, and between LMS-HA to 4 and 8 weeks of healing. The surface characterization showed a deep, rough, and regular topography provided by the laser conditioning, that was followed by the HA coating.Conclusions: Based on these results, it was possible to conclude that the implants with laser surface modification associated with HA biomimetic coating can shorten the implant healing period by the increase of bone implant interaction during the first 2 months after implant placement. (C) 2009 American Association of Oral and Maxillofacial Surgeons J Oral Maxillofac Surg 67:1706-1715, 2009
Resumo:
Surface morphology changes induced by argon laser irradiation (514 nm) on disperse red 13 (DR13) films prepared by physical vapor deposition (PVD) were investigated. Atomic force microscopy was used to characterize the irradiated sample for different periods of irradiation. Needle-shape structures are observed which are attributed to the symmetry of DR13 molecules. The film becomes increasingly closely packed with the irradiation, with lower root mean square roughness for long exposure times. This is due to photoisomerization of DR13 molecules and probably heating of the sample, which can provide the required mobility for the molecular rearrangement. The rearrangement is such that voids in the film are filled in upon irradiating the sample, thus decreasing the film roughness and increasing the packing.
Resumo:
The purpose of this study was to evaluate commercially pure titanium implant surfaces modified by laser beam (LS) and LS associated with sodium silicate (SS) deposition, and compare them with machined surface (MS) and dual acid-etching surfaces (AS) modified. Topographic characterization was performed by scanning electron microscopy-X-ray energy dispersive spectroscopy (SEM-EDX), and by mean roughness measurement before surgery. Thirty rabbits received 60 implants in their right and left tibias. One implant of each surface in each tibia. The implants were removed by reverse torque for vivo biomechanical analysis at 30, 60, and 90 days postoperative. In addition, the surface of the implants removed at 30 days postoperative was analyzed by SEM-EDX. The topographic characterization showed differences between the analyzed surfaces, and the mean roughness values of LS and SS were statistically higher than AS and MS. At 30 days, values removal torque LS and SS groups showed a statistically significant difference (p < 0.05) when compared with MS and AS. At 60 days, groups LS and SS showed statistically significant difference (p < 0.05) when compared with MS. At 90 days, only group SS presented statistically higher (p < 0.05) in comparison with MS. The authors can conclude that physical chemistry properties and topographical of LS and SS implants increases bone-implant interaction and provides higher degree of osseointegration when compared with MS and AS. © 2012 Wiley Periodicals, Inc.
Resumo:
An a-C:H thin film deposited by plasma immersion ion implantation and deposition on alloy steel (16MnCr5) was analyzed using a self-consistent ion beam analysis technique.In the self-consistent analysis, the results of each individual technique are combined in a unique model, increasing confidence and reducing simulation errors.Self-consistent analysis, then, is able to improve the regular ion beam analysis since several analyses commonly used to process ion beam data still rely on handling each spectrum independently.The sample was analyzed by particle-induced x-ray emission (for trace elements), elastic backscattering spectrometry (for carbon), forward recoil spectrometry (for hydrogen) and Rutherford backscattering spectrometry (for film morphology).The self-consistent analysis provided reliable chemical information about the film, despite its heavy substrate.As a result, we could determine precisely the H/C ratio, contaminant concentration and some morphological characteristics of the film, such as roughness and discontinuities.© 2013 Elsevier B.V.All rights reserved.
Resumo:
Objectives: the purpose of this study was to evaluate the surfaces of commercially pure titanium (cpTi) implants surface modified by laser beam (LS), by laser beam associated with sodium silicate deposition (SS) and compare them with surfaces modified by dual-acid etched (AS) and with machined surface (MS). Methods: thirty rabbits received two implants each (one for each tibia). After 30, 60 and 90 days postoperative, the implants were removed by reverse torque for biomechanical analysis and surfaces were analyzed by scanning electron microscopy (SEM) and X-ray energy dispersive spectroscopy (EDS). Results: the mean values of reverse torque at 30, 60 and 90 days postoperative were respectively 24.60, 43.60 e 60.40 N.cm to MS, 43.00, 68.20 e 63.80 N.cm to AS group, 59.80, 76.60 e 78.00 N.cm to LS group and 63.00, 75.40 e 76.60 N.cm to SS group. At 30 days, LS and SS groups showed statistically significant difference (p<0.05) compared to the other groups. At 60 days, LS and SS groups showed statistically significant difference (p<0.05) when compared to MS. Conclusions: it was concluded that SL and SS implants' biomechanical and topographical properties increased bone-implant interaction when compared to the AS and MS implants.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
O objetivo deste trabalho foi avaliar o efeito de fontes e níveis de tanino em rações para tilápia-do-nilo (Oreochromis niloticus), durante a engorda, sobre o desempenho produtivo e deposição lipídica corporal. Foram utilizados 342 peixes, distribuídos em 18 tanques. As rações foram preparadas com milho, variedades de sorgo com baixo e alto teor de tanino, e com ácido tânico a 0,08, 0,34, e 0,60%. Ganho de peso, conversão alimentar aparente e taxa de eficiência protéica não foram influenciados pelos tratamentos. A maior deposição lipídica corporal foi observada nas dietas com ácido tânico (14,39%); a dieta de sorgo com alto teor de tanino resultou em carcaças mais magras (12,01%) do que as de sorgo com baixo teor de tanino (13,31%). Dietas com sorgo proporcionaram menores teores de gordura visceral. A presença de tanino nas rações não prejudicou o desempenho produtivo da tilápia-do-nilo.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
A possibilidade do desenvolvimento de técnicas de aplicação de produtos fitossanitários mais seguras, com menores volumes de calda, número de aplicações e deriva, aliados à necessidade de se obter melhores níveis de controle dos agentes nocivos às plantas cultivadas, justificam o uso da assistência de ar junto à barra de pulverização. Com o objetivo de avaliar a deposição da pulverização na cultura do feijoeiro (Phaseolus vulgaris), em presença e ausência da assistência de ar junto à barra de pulverização, com diferentes pontas de pulverização e volumes de calda, foi conduzido um experimento em delineamento inteiramente casualizado, utilizando-se como traçador o óxido cuproso. Alvos artificiais (papel filtro com 3 x 3 cm) foram afixados nas superfícies adaxial e abaxial de folíolos posicionados nos terços superior e inferior de plantas, selecionadas ao acaso, distribuídas perpendicularmente ao deslocamento do pulverizador. Após a aplicação do traçador os coletores foram lavados individualmente em solução extratora de ácido nítrico a 1,0 mol L-1. A determinação quantitativa dos depósitos foi realizada com o uso da espectrofotometria de absorção atômica. A assistência de ar junto à barra de pulverização não aumentou a deposição do traçador em folíolos de feijoeiro, aos 48 dias após a emergência da cultura.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
A.C.P. Rodrigues-Costa, D. Martins, N.V. Costa, and M.R.R. Pereira. 2011. Spray deposition on weeds of common bean crops. Cien. Inv. Agr. 38(3): 357-365. Weed control failure in common bean (Phaseolus vulgaris L.) production may be related to inappropriate herbicide application techniques. The purpose of this study, therefore, was to evaluate the amount of spray solution deposition that occurred on the weeds, Bidens pilosa L. and Brachiaria plantaginea (Link) Hitch., both within and between rows of common beans. The research was arranged in a randomized block design with four replications. The following 6 spray nozzles were used: flat fan nozzles XR 110015 VS (150 L ha(-1)) and XR 11002 VS (200 L ha(-1)); cone nozzles TX VK 6 (150 L ha(-1)) and TX VK 8 (200 L ha(-1)); and twin flat fan nozzles TJ60 11002 VS (150 L ha(-1)) and TJ60 11002 VS (200 L ha-1). The results showed that the loss of the spray solution on the soil occurred mainly within the bean rows and with a high intensity when using a nozzle spraying 200 L ha(-1). At 30 days after sowing, the TX (150 L ha(-1)) nozzle was the only nozzle that promoted deposits of less than 210.0 mu L g(-1) of dry mass. The spray nozzles showed a good performance in the deposition of the spray solution on the weeds that occurred both within and between the rows. However, for both species there was great variation in individual deposits depending on their location in relationship to the plants.
Resumo:
The effect of application with different nozzle types and volume rates on spray deposition in the V3 stage of two soybean cultivars was evaluated. The experiments were conducted in the Facultad de Ciencias Agronomicas of the UNESP-Botucatu/SP. The nozzles evaluated were an air induced flat fan nozzle (Al 11015 at 150 L ha(-1), Al 11002 at 200 and 250 L ha(-1)), a twin flat fan nozzle (TJ 60 11002 at 150, 200 and 250 L ha(-1)), and a cone nozzle (TX 6 at 150 L ha(-1), TX 8 at 150 L ha(-1) and TX 10 at 250 L ha(-1)). To evaluate spray deposition on the plants, a tracer (Brilliant Blue FD&C-1) was added. The experimental design was random blocks with four replications. Deposition on plants was determined by absorbancy reading in 630 nm wavelength. The data were adjusted to a calibration curve and transformed into deposited spray volume in mL. The relationship deposition per unit of dry matter was adjusted to a regression curve (Gompertz model). In cultivar CD 208, the highest deposit was for the larger volumes and for the treatment TX 8 200 L ha(-1). The most uniform treatments were all the nozzles with the volume 150 L ha(-1) and the TJ60 nozzle for 200 1, ha(-1). In cultivar CD 216, the greatest spray depositions were achieved with the treatments Al at 200 and 250 L ha(-1) and TJ 60 at 250 L ha(-1), and the most uniform treatments were the TX 6 and TJ60 nozzles for the volume150 L ha(-1).
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)