42 resultados para Australasian Digital Thesis Program

em Repositório Institucional UNESP - Universidade Estadual Paulista "Julio de Mesquita Filho"


Relevância:

40.00% 40.00%

Publicador:

Resumo:

Pós-graduação em Televisão Digital: Informação e Conhecimento - FAAC

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This work aimed to study the reproduction and description of technique for digital sampling images during rats gait and determination of the sciatic functional index (SFI), through a glass walkway to obtain shoots with a digital camera. After controlled injury by strangulation of sciatic nerve, with 3mm of length, during 30 seconds, using hemostatic forceps, a group of 32 rats was performed 24 hours before the lesion which served as control and 24 hours, 7, 14 and 21 days after injury. The tests consisted in the filming and shooting each animal in order to observe the view from below (by a mirror to 45 degrees) and subsequently analyzed using the IMAGE-J program. Measures were taken from the lengths of the legs (right and left), and the distance between the ankle. In the analysis of IFC, values close to zero (0) suggest that the function of the sciatic nerve is still preserved and values coming from "less one hundred" (-100) indicate total loss of function. It was verified in this study that 24 hours before surgery the average SFI was -7.07 +/- 7.88 and 24 hours after injury these values rose to an average of -77.95 +/- 13.81, being about 10 times larger, where 78% of the animals showed 60 to 100% of functional loss in motor activity, demonstrated by the gradual recovery over the days analyzed, confirming the accuracy and effectiveness of the proposed methodology. These results suggest that studies can be conducted to simplify and reduce costs using the technique for digital images of footprints during rats gait in the laboratory.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Today, the trend within the electronics industry is for the use of rapid and advanced simulation methodologies in association with synthesis toolsets. This paper presents an approach developed to support mixed-signal circuit design and analysis. The methodology proposed shows a novel approach to the problem of developing behvioural model descriptions of mixed-signal circuit topologies, by construction of a set of subsystems, that supports the automated mapping of MATLAB (R)/SINIULINK (R) models to structural VHDL-AMS descriptions. The tool developed, named (MSSV)-S-2, reads a SIMULINK (R) model file and translates it to a structural VHDL-AMS code. It also creates the file structure required to simulate the translated model in the SystemVision (TM). To validate the methodology and the developed program, the DAC08, AD7524 and AD5450 data converters were studied and initially modelled in MATLAB (R)/SIMULINK (R). The VHDL-AMS code generated automatically by (MSSV)-S-2, (MATLAB (R)/SIMULINK (R) to SystemVision (TM)), was then simulated in the SystemVision (TM). The simulation results show that the proposed approach, which is based on VHDL-AMS descriptions of the original model library elements, allows for the behavioural level simulation of complex mixed-signal circuits.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

INTRODUÇÃO: A utilização da fotogrametria computadorizada em prol da goniometria, ou vice-versa, na prática clínica ainda necessita de fundamentações consistentes. OBJETIVOS: Os objetivos deste estudo foram: verificar a confiabilidade inter e intraexaminadores avaliadores na quantificação das medidas angulares obtidas a partir da fotogrametria computadorizada e a goniometria e determinar a confiabilidade paralela entre esses dois diferentes instrumentos de avaliação. MATERIAIS E MÉTODOS: 26 voluntários e 4 examinadores foram utilizados no estudo. A coleta foi realizada em 4 etapas sequenciais: demarcação dos pontos anatômicos de referência, mensuração e registro dos valores goniométricos, captação da imagem do voluntário com os marcadores fixados no corpo e avaliação do registro fotográfico no programa ImageJ. RESULTADOS: O goniômetro é um instrumento confiável na maioria das evidências, porém, a confiabilidade das medições depende principalmente da uniformização dos procedimentos. Considerações metodológicas relativas ao estabelecimento de confiabilidade e padronização da colocação dos marcadores se fazem necessárias, de modo a oferecer opções de avaliação ainda mais confiáveis para a prática clínica. CONCLUSÃO: Ambos os instrumentos são confiáveis e aceitáveis, porém, mais evidências ainda são necessárias para suportar a utilização desses instrumentos, pois poucos pesquisadores têm utilizado o mesmo desenho de estudo, e a comparação dos resultados entre eles muitas vezes são difíceis.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

An efficient technique to cut polygonal meshes as a step in the geometric modeling of topographic and geological data has been developed. In boundary represented models of outcropping strata and faulted horizons polygonal meshes often intersect each other. TRICUT determines the line of intersection and re-triangulates the area of contact. Along this line the mesh is split in two or more parts which can be selected for removal. The user interaction takes place in the 3D-model space. The intersection, selection and removal are under graphic control. The visualization of outcropping geological structures in digital terrain models is improved by determining intersections against a slightly shifted terrain model. Thus, the outcrop line becomes a surface which overlaps the terrain in its initial position. The area of this overlapping surface changes with respect to the strike and dip of the structure, the morphology and the offset. Some applications of TRICUT on different real datasets are shown. TRICUT is implemented in C+ + using the Visualization Toolkit in conjunction with the RAPID and TRIANGLE libraries. The program runs under LINUX and UNIX using the MESA OpenGL library. This work gives an example of solving a complex 3D geometric problem by integrating available robust public domain software. (C) 2002 Elsevier B.V. Ltd. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objectives: To compare simulated periodontal bone defect depth measured in digital radiographs with dedicated and non-dedicated software systems and to compare the depth measurements from each program with the measurements in dry mandibles.Methods: Forty periodontal bone defects were created at the proximal area of the first premolar in dry pig mandibles. Measurements of the defects were performed with a periodontal probe in the dry mandible. Periapical digital radiographs of the defects were recorded using the Schick sensor in a standardized exposure setting. All images were read using a Schick dedicated software system (CDR DICOM for Windows v.3.5), and three commonly available non-dedicated software systems (Vix Win 2000 v.1.2; Adobe Photoshop 7.0 and Image Tool 3.0). The defects were measured three times in each image and a consensus was reached among three examiners using the four software systems. The difference between the radiographic measurements was analysed using analysis of variance (ANOVA) and by comparing the measurements from each software system with the dry mandibles measurements using Student's t-test.Results: the mean values of the bone defects measured in the radiographs were 5.07 rum, 5.06 rum, 5.01 mm and 5.11 mm for CDR Digital Image and Communication in Medicine (DICOM) for Windows, Vix Win, Adobe Photoshop, and Image Tool, respectively, and 6.67 mm for the dry mandible. The means of the measurements performed in the four software systems were not significantly different, ANOVA (P = 0.958). A significant underestimation of defect depth was obtained when we compared the mean depths from each software system with the dry mandible measurements (t-test; P congruent to 0.000).Conclusions: the periodontal bone defect measurements in dedicated and in three non-dedicated software systems were not significantly different, but they all underestimated the measurements when compared with the measurements obtained in the dry mandibles.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose: To determine palpebral dimensions and development in Brazilian children using digital images. Methods: An observational study was performed measuring eyelid angles, palpebral fissure area and interpupillary distance in 220 children aged from 4 to 72 months. Digital images were obtained with a Sony Lithium movie camera (Sony DCR-TRV110, Brazil) in frontal view from awake children in primary ocular position; the object of observation was located at pupil height. The images were saved to tape, transferred to a Macintosh G4 (Apple Computer Inc., USA) computer and processed using NIH 1.58 software (NTIS, 5285 Port Royal Rd., Springfield, VA 22161, USA). Data were submitted to statistical analysis. Results: All parameters studied increased with age. The outer palpebral angle was greater than the inner, and palpebral fissure and angles showed greater changes between 4 and 5 months old and at around 24 to 36 months. Conclusion: There are significant variations in palpebral dimensions in children under 72 months old, especially around 24 to 36 months. Copyright © 2006 Informa Healthcare.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Today, the trend within the electronics industry is for the use of rapid and advanced simulation methodologies in association with synthesis toolsets. This paper presents an approach developed to support mixed-signal circuit design and analysis. The methodology proposed shows a novel approach to the problem of developing behvioural model descriptions of mixed-signal circuit topologies, by construction of a set of subsystems, that supports the automated mapping of MATLAB®/SIMULINK® models to structural VHDL-AMS descriptions. The tool developed, named MS 2SV, reads a SIMULINK® model file and translates it to a structural VHDL-AMS code. It also creates the file structure required to simulate the translated model in the System Vision™. To validate the methodology and the developed program, the DAC08, AD7524 and AD5450 data converters were studied and initially modelled in MATLAB®/ SIMULINK®. The VHDL-AMS code generated automatically by MS 2SV, (MATLAB®/SIMULINK® to System Vision™), was then simulated in the System Vision™. The simulation results show that the proposed approach, which is based on VHDL-AMS descriptions of the original model library elements, allows for the behavioural level simulation of complex mixed-signal circuits.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A digital-desk pilot program, named One Laptop Per Child (OPLC), in Brazil uses a unique display design to provide an interactive interface developed to enhance education and minimize ergonomic concerns. The one-to-one computer strategy as proposed by Nicholas Negroponte is a way of circumventing the tragedy of the locked computer lab because it gives children full access to computers anytime. The OLPC program has focused on a solution that minimizes power consumption, which also limits the display's maximum size and processor performance because the LCD backlights are responsible for a significant part of the power consumption in laptops. The government has also developed a new type of low-cost tablet that is based on a resistive principle. High transparencies can be obtained in the 90% range in the tablet, while robustness is guaranteed by the outstanding tribological characteristics of Sn02 on glass.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Pós-graduação em Televisão Digital: Informação e Conhecimento - FAAC

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Pós-graduação em Televisão Digital: Informação e Conhecimento - FAAC

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Pós-graduação em Televisão Digital: Informação e Conhecimento - FAAC

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Pós-graduação em Televisão Digital: Informação e Conhecimento - FAAC

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)