54 resultados para Analogs

em Repositório Institucional UNESP - Universidade Estadual Paulista "Julio de Mesquita Filho"


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The structural specificity of alpha-PMTX, a novel peptide toxin derived from wasp venom has been studied on the neuromuscular synapse in the walking leg of the lobster. alpha-PMTX is known to induce repetitive action potentials in the presynaptic axon due to sodium channel inactivation. We synthesized 29 analogs of alpha-PMTX by substituting one or two amino acids and compared threshold concentrations of these mutant toxins for inducing repetitive action potentials. In 13 amino acid residues of alpha-PMTX, Arg-1, Lys-3 and Lys-12 regulate the toxic activity because substitution of these basic amino acid residues with other amino acid residues greatly changed the potency. Determining the structure-activity relationships of PMTXs will help clarifying the molecular mechanism of sodium channel inactivation. (C) 2000 Elsevier B.V. Ireland Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Angiotensin II (AngII) and bradykinin (BK) derivatives containing the TOAC (2,2,6,6-tetramethylpiperidine-N-oxyl-4-amino-4-carboxylic acid) spin label were synthesized by solid phase methodology. Ammonium hydroxide (pH 10, 50degreesC, 1 h) was the best means for reverting nitroxide protonation occurring during peptide cleavage. EPR spectra yielded rotational correlation times for internally labeled analogs that were nearly twice as large as those of N-terminally labeled analogs. Except for TOAC(1)-AngII and TOAC(0)-BK, which showed high intrinsic activities, other derivatives were inactive in smooth muscle preparations. These active paramagnetic analogs may be useful for conformational studies in solution and in the presence of model and biological membranes. (C) 2002 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

1. Intracerebroventricular (I.C.V.) infusion (60 ng h-1) of Isoleu5-angiotensin II (Isoleu5-AngII) and des-amine-angiotensin II (des-amine-AngII) in rats caused increased drinking behaviour and an increase in arterial blood pressure.2. Des-amine-AngII caused similar increases in heart rate and arterial blood pressure as AngII.3. Previous I.C.V. injection of the antagonists [Leu8]-AngII, des-amine-[Leu8]-AngII and octanoyl-[Leu8]-AngII prevented the increases in heart rate and blood pressure produced by I.C.V. infusion of AngII and caused partial reduction of the dipsogenic response.4. The three antagonists had no effect on the increase in arterial blood pressure and heart rate caused by des-amine-AngII. The drinking response was reduced by previous injection of [Leu8]-AngII and des-amine-[Leu8]-AngII but not by octanoyl-[Leu8]-AngII.5. In conclusion, Isoleu5-AngII and des-amine-AngII increase drinking behaviour, arterial blood pressure and heart rate when infused into the cerebral ventricle of rats. The study with the antagonists showed that des-amine-AngII probably binds more strongly to AngII-receptors.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: Subclinical inflammation may be observed in patients using topical antiglaucomatous drugs. The objective of this study was to investigate inflammation in conjunctiva of glaucoma patients using prostaglandin analogs, by the detection of an immunogenetic marker (HLA-DR) and compare the effect of 3 different drugs: latanoprost, bimatoprost, and travoprost in the induction of this inflammation. SUBJECTS AND METHODS: Thirty-three patients with primary open-angle glaucoma were evaluated without and with prostaglandin analogs topical therapy. Imprints of conjunctival cells were obtained, fixed on glass slides, and prepared for immunohistochemical analysis. RESULTS: Before the use of prostaglandin analogs, 4 of the 33 patients evaluated presented expression of HLA-DR in the conjunctiva (mild). After 1 month on prostaglandin analog treatment, all but 1 patient presented HLA-DR staining. HLA-DR expression of these 32 patients was scored as mild (19 patients), medium (11 patients), or intense (2 patients). The differences were statistically significant both when the presence and the increased expression of HLA-DR were considered (P<0.001). When the 3 different groups were analyzed (latanoprost, bimatoprost, and travoprost) no statistically significant difference was found (P=0.27). CONCLUSIONS: The use of prostaglandin analogs eye drops provokes a subclinical inflammatory reaction, observed by HLA-DR expression, even after a short period of treatment, independently of the class of the prostaglandin analogs used. © 2009 Lippincott Williams & Wilkins, Inc.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The Topliss method was used to guide a synthetic path in support of drug discovery efforts toward the identification of potent antimycobacterial agents. Salicylic acid and its derivatives, p-chloro, p-methoxy, and m-chlorosalicylic acid, exemplify a series of synthetic compounds whose minimum inhibitory concentrations for a strain of Mycobacterium were determined and compared to those of the reference drug, p-aminosalicylic acid. Several physicochemical descriptors (including Hammett's sigma constant, ionization constant, dipole moment, Hansch constant, calculated partition coefficient, Sterimol-L and -B-4 and molecular volume) were considered to elucidate structure-activity relationships. Molecular electrostatic potential and molecular dipole moment maps were also calculated using the AM1 semi-empirical method. Among the new derivatives, m-chlorosalicylic acid showed the lowest minimum inhibitory concentration. The overall results suggest that both physicochemical properties and electronic features may influence the biological activity of this series of antimycobacterial agents and thus should be considered in designing new p-aminosalicylic acid analogs.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Tigecycline is a new glycylcycline with an expanded broad-spectrum antibiotic, including inhibition of Gram-positive, Gram-negative, atypical, anaerobic, and antibiotic-resistant organisms. Trials have demonstrated that tigecycline is noninferior to the comparators for the treatment of complicated skin and skin structure infections as well as complicated intra-abdominal infections. Tigecycline is only available as an intravenous preparation and analytical methods to its quantitation in pharmaceutical products has not been published to date. This review examined tigecycline characteristics, the spectrum and mechanism of action, pharmacokinetics, applications, and, mainly, the instrumental conditions of published chromatographic methods used to measure tigecycline, its metabolites, and some analogs in clinical and biologic research.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: The aim of this study was to compare 2 different methods of assessment of implants at different inclinations (90 degrees and 65 degrees)-with a profilometer and AutoCAD software. Materials and Methods: Impressions (n = 5) of a metal matrix containing 2 implants, 1 at 90 degrees to the surface and 1 at 65 degrees to the surface, were obtained with square impression copings joined together with dental floss splinting covered with autopolymerizing acrylic resin, an open custom tray, and vinyl polysiloxane impression material. Measurement of the angles (in degrees) of the implant analogs were assessed by the same blinded operator with a profilometer and through analysis of digitized images by AutoCAD software. For each implant analog, 3 readings were performed with each method. The results were subjected to a nonparametric Kruskal-Wallis test, with P <= .05 considered significant. Results: For implants perpendicular to the horizontal surface of the specimen (90 degrees), there were no significant differences between the mean measurements obtained with the profilometer (90.04 degrees) and AutoCAD (89.95 degrees; P=.9142). In the analyses of the angled implants at 65 degrees in relation to the horizontal surface of the specimen, significant differences were observed (P=.0472) between the mean readings with the profilometer (65.73 degrees) and AutoCAD (66.25 degrees). Conclusions: The degrees of accuracy of implant angulation recording vary among the techniques available and may vary depending on the angle of the implant. Further investigation is needed to determine the best test conditions and the best measuring technique for determination of the angle of the implant in vitro.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Different transfer impression techniques for implant-supported prostheses have been suggested to obtain a working cast. This article describes and illustrates clinical and laboratory pros-thodontic procedures to transfer implant positions with splinted transfer copings and without impression material to form a laboratory analog transfer template. With this technique, a preliminary cast is modified to place the analogs according to a corrected position and obtain the master cast. Although this technique does not record adjacent tissues, it is a simple procedure, less time consuming, and easily performed.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: The objective of this study was to evaluate and compare 3 impression techniques for osseointegrated implant transfer procedures.Materials and Methods: (1) Group Splinted with Acrylic Resin (SAR), impression with square copings splinted with prefabricated autopolymerizing acrylic resin bar; (2) Group Splinted with Light-Curing Resin (SLR), impression, with square copings splinted with prefabricated light-curing composite resin bar; (3). Group Independent Air-abraded (IAA), impression with independent square coping aluminum oxide air-abraded. Impression procedures were performed with polyether material, and the data obtained was compared with a control group. These were characterized by metal matrix (MM) measurement values of the implants inclination positions at 90 and 05 degrees in relation to the matrix surface. Readings of analogs and implant inclinations were assessed randomly through graphic computation AutoCAD software. Experimental groups angular deviation with MM were submitted to analysis of variance and means were compared through Tukey's test (P < 0.05).Results: There was no statistical significant difference between SAR and SLR experimental groups and MM for vertical and angulated implants. Group IAA presented a statistically significant difference for angulated implants.Conclusion: It was concluded within the limitations of this study, that SAR and SLR produced more accurate casts than IAA technique, which presented inferior results.