15 resultados para Amplificador de transimpedância
em Repositório Institucional UNESP - Universidade Estadual Paulista "Julio de Mesquita Filho"
Resumo:
In this work we report the development of a tube amplifier built to be used in magnetic probe diagnostic of plasma. The probe is used to measure the magnetic field in the theta-pinch system presently running in our university. We present the calculations and procedures to determine the configuration of circuits and specify the components of the power supply, the preamp stage and the power stage. The circuit configuration and the characteristics of the components was obtained. A representative model of the system behavior gave the transfer function of the amplifier. Theoretical predictions of frequency response and the feedback effects were compared to the experimental values and showed very good agreement. The amplifier works between a frequency bandwidth of 20 an 30 kHz and supply a maximum power of 12 W
Resumo:
This work presents the development of a graphical interface to the Lock-in Amplifier, which is used in physiological studies on the motility of the gastrointestinal tract in rats and signal processing. With a simple and low cost instrumentation, the resources offered by the virtual interface of LabVIEW software allows the creation of commands similar to the actual instrument that, through communication via standard serial port, transmits data between a PC and peripheral device performing specific and particular needs in the amplifier. Created for the lock-in amplifier model SR830 Stanford Research Systems, the remote manipulation gives the user greater accessibility in the process of configuration and calibration. And, since the software is installed, there is the advantage of eliminating the need of purchase new devices to upgrade the system. The commands created were made to perform six basic modifications that are used in routine of the Biomagnetism Laboratory. The instrumentation developed has the following controls: Amplitude, Frequency, Time Constant, slope low pass filter, sensitivity and offset
Resumo:
Atualmente, diante das técnicas atuais, a manometria tem sido relegada a plano secundário durante a cateterização cardíaca. No entanto, ainda fornece importantes informações para identificação e avaliação das doenças cardiovasculares. Os dados coletados durante os exames possibilitam a obtenção de variáveis quantitativas e qualitativas, as quais podem ser comparadas aos padrões normais. Os sistemas manométricos são compostos por transdutor, amplificador e registrador, que, em conjunto, devem espelhar com fidelidade a morfologia e os valores das variáveis analisadas. Para atingir esse objetivo, é necessário desempenho adequado de todos os componentes. Se uma determinada informação é de extrema relevância, o operador deve gastar tempo suficiente para obtê-la de maneira inequívoca. Assim, o operador deve estar familiarizado com os sistemas manométricos e com as fontes de erro relacionadas com as técnicas de registro, cateteres, conectores e fluidos. Com os fundamentos analisados neste manuscrito, salientamos que deve ser dispensada atenção às ondas de pressão usadas nas interpretações da fisiopatologia das doenças cardiovasculares.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Pós-graduação em Desenvolvimento Humano e Tecnologias - IBRC
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Compreendida por um dispositivo para determinação do espectro de substâncias sólidas e líquidas, com possibilidades de medições in vivo, e exibindo diversas vantagens sobre os dispositivos precedentes, que apresenta uma relação sinalruído excelente e comparável a uma câmara fotoacústica com microfone convencional com a grande vantagem de ser aberta. O dispositivo é composto por um detector transparente de radiação de Tantalato de Lítio, ao qual é acoplada, por contato físico, a amostra a ser analisada. Os eletrodos do detector são em formato de anel, sendo recobertos por uma camada de óxido de índio-estanho (ITO). Ao detector deve ser acoplado um amplificador eletrónico com elevada impedância de entrada.
Resumo:
The use of multimodal neuroimaging techniques has been helpful in the investigation of epileptogenic zone in patients with refractory epilepsies. This work aims to describe an ictal event during EEG-fMRI performed simultaneously in a 39-year-old man with refractory epilepsy. The EEG data were recorded at a sampling rate of 5 kHz, using a BrainAmp (BrainProducts, München, Germany) amplifier, with 64 MR (magnetic resonance) compatible Ag/AgCl electrodes. MR images were acquired using a 3T scanner in 3 sequences of 6 minutes of echo-planar images (EPIs), with TR = 2s, being the last sequence stopped after the ictal event. The EEG was corrected for gradient and pulse artifacts using the Brain Vision Analyzer2 software (BrainProducts), and the functional images were realigned, slice-timing corrected, normalized and smoothed. The start of the ictal changes was used for the evaluation of the BOLD response in MR images, using a t-test with a minimum cluster of 5 voxels, p <0.005 (T>2.5). The patient had a partial complex seizure, as noted by neurologist. The fMRI data showed positive BOLD responses (activation) in dysplastic areas, but showed the most significant activation outside the lesion, in areas compatible with secondary spread of the epileptic focus, probably caused by motor reaction also observed during the seizure. As a conclusion, we note that the technique of EEG-fMRI can detect the epileptogenic zone in patients with refractory epilepsy, but areas of dissemination of primary epileptogenic focus may show significant activation, introducing additional difficulties to the interpretation of the results
Resumo:
Pós-graduação em Engenharia Elétrica - FEIS
Resumo:
Pós-graduação em Engenharia Elétrica - FEIS
Resumo:
Objetivo: O presente estudo buscou um indicador de classificação de presença de dor lombar baseado no tempo de resistência isométrica e em variáveis eletromiográficas. Material e Métodos: Para tanto participaram do presente estudo 40 voluntários do gênero masculino, os quais foram divididos em dois grupos de 20 voluntários, a saber: grupo sem dor lombar e grupo com dor lombar. Para a captação dos sinais eletromiográficos foram utilizados eletrodos de superfície descartáveis passivos de contato bipolar de Ag/AgCl conectados a um pré-amplificador de ganho de 20 vezes. A distância intereletrodos foi fixa em 20mm. Os eletrodos foram dispostos bilateralmente sobre os músculos longuíssimo do tórax, iliocostal lombar e multífido lombar. Foi utilizado um módulo de aquisição de sinais biológicos de 8 canais no qual foram conectados os eletrodos. Para a aquisição dos sinais foi utilizado um software específico (Aqdados 7-Lynx®) com a freqüência de amostragem calibrada em 2000 Hz. Com os equipamentos preparados e os eletrodos conectados os voluntários realizaram o teste de Sorensen, o qual consiste em sustentar o peso do tronco, em posição horizontal, até a exaustão voluntária. Para a análise dos sinais eletromiográficos foram utilizadas rotinas específicas em ambiente MatLab (MathWorks®). Neste software foi obtida a atividade eletromiográfica dos músculos selecionados durante o teste de contração isométrica até a exaustão para a determinação dos valores de root means quare (RMS) em pacotes de 1s a cada 0.5s (overlap). De cada espectro foram determinados os valores de frequência mediana (FM) e frequência média (Fmed) do sinal. Com a RMS, FM e Fmed foram obtidos também os valores de Razão ML/LT, Razão ML/IL e Razão IL/LT para cada variável. Com isto, os valores de RMS, FM e Fmed, juntamente com os valores de Razão ML/LT, Razão ML/IL e Razão IL/LT de cada variável, foram associados com o tempo...