9 resultados para Alcohol oxidation
em Repositório Institucional UNESP - Universidade Estadual Paulista "Julio de Mesquita Filho"
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
A nickel modified boron doped diamond (Ni-BDD) electrode and nickel foil electrode were used in the determination of methanol in alkaline solutions. The Ni-BDD electrode was electrodeposited from a 1 mM Ni(NO(3))(2) solution (pH 5), followed by repeat cycling in KOH. Subsequent analysis utilised the Ni(OH)(2)/NiOOH redox couple to electrocatalyse the oxidation of methanol. Methanol was determined to limits of 0.3 mM with a sensitivity of 110 nA/mM at the Ni-BDD electrode. The foil electrode was less sensitive achieving a limit of 1.6 mM and sensitivity of 27 nA/mM. SEM analysis of the electrodes found the Ni-BDD to be modified by a quasi-random microparticle array.
Resumo:
Pós-graduação em Química - IQ
Resumo:
Alcoholism is rampant in modern society and some antioxidant compound could perhaps be useful to reduce the damage done by alcohol consumption and abstinence. The present study was undertaken to investigate the association of N-acetylcysteine (NAC) intake, alcoholism, and alcohol abstinence on lipid profile, in vivo low-density lipoprotein (LDL) oxidation, oxidative stress, and antioxidant status in serum and liver of rats. Initially, male Wistar 30 rats were divided into two groups: (C, N = 6) given standard chow and water; (E, N = 24) receiving standard chow and aqueous ethanol solution in semi-voluntary research. After 30 days of ethanol exposure, (E) group was divided into four subgroups (N = 6/group): (E-E) continued drinking 30% ethanol solution; (E-NAC) drinking ethanol solution containing 2 g/L NAC (AB) changed ethanol solution to water; (AB-NAC) changed ethanol to aqueous solution 2 g/L NAC. After 15 days of the E-group division, E-E rats had higher serum alanine transaminase, lower body weight, and surface area, despite higher energy intake than C. E-E rats had also lower feed efficiency, dyslipidemia with enhanced triacyl glycerol, very low-density lipoprotein (VLDL), lipid hydroperoxide (LH) and in vivo oxidized-LDL (ox-LDL). AB, E-NAC, and AB-NAC rats ameliorated serum oxidative stress markers and normalized serum lipids. E-E rats had higher hepatic LH and lower reduced glutathione (GSH)/oxidized glutathione (GSSG) ratio than C, indicating hepatic oxidative stress. AB and E-NAC rats normalized hepatic LH, GSSG, and the GSH/GSSG ratio, compared to E-E. AB-NAC rats had the lowest serum ox-LDL, hepatic LH levels, and the highest GSH reductase activity in hepatic tissue. In conclusion, the present study brought new insights into alcohol consumption, because ethanol exposure enhanced serum in vivo ox-LDL, as well as serum and hepatic oxidative stress. N-acetylcysteine offers promising therapeutic value to inhibit ethanol-induced adverse effects. Ethanol withdrawal had beneficial effects on serum lipids, but was more effective when coupled with NAC supplementation. Ethanol abstinence and NAC intake interact synergistically, improving serum lipids and hepatic antioxidant defenses. (c) 2009 Elsevier B.V. All rights reserved.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
In the present paper we investigated the effect of adsorbed PVA on Pt electrodes on classic electrochemical processes such as hydrogen UPD, oxygen reduction and CO electro-oxidation. Upon adsorption PVA blocks roughly 50% of the hydrogen sites and can not be removed from the Pt surface through cycling in the potential range of 0.05-1.0 V vs. RHE. Potentiodynamic experiments under controlled hydrodynamic conditions provided by rotating disk electrode experiments showed a negative impact of the adsorbed PVA on the oxygen reduction reaction (ORR). Cyclic-voltammetry results revealed that not even CO was able to remove PVA from the Pt surface. Regarding the oxidation of CO, the adsorbed polymer positively shifted the CO oxidation peak potential, therefore higher potentials are required to free the Pt surface from CO poisoning. In situ Fourier transform infrared spectroscopy evidenced that the presence of PVA shifted the linearly bound CO frequency toward higher wavenumbers, a process found to be independent of the Pt surface orientation. In situ electrochemical X-ray absorption spectroscopy results showed that PVA also impacted the electronic properties of platinum by decreasing the occupancy of the Pt conducting 5d band. Our findings clearly support the efforts toward understanding the nature of the interaction between polymers and metallic surfaces as well as the impact on technological applications (e.g. in PEMFCs). © 2013 Elsevier Ltd. All rights reserved.