47 resultados para Air Pollution Environmental aspects

em Repositório Institucional UNESP - Universidade Estadual Paulista "Julio de Mesquita Filho"


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Studies of cooking-generated NO2 effects are rare in occupational epidemiology. In the present study, we evaluated the lung function of professional cooks exposed to NO2 in hospital kitchens. We performed spirometry in 37 cooks working in four hospital kitchens and estimated the predicted FVC, FEV1 and FEF25-75, based on age, sex, race, weight, and height, according to Knudson standards. NO2 measurements were obtained for 4 consecutive days during 4 different periods at 20-day intervals in each kitchen. Measurements were performed inside and outside the kitchens, simultaneously using Palm diffusion tubes. A time/exposure indicator was defined as representative of the cumulative exposure of each cook. No statistically significant effect of NO2 exposure on FVC was found. Each year of work as a cook corresponded to a decrease in predicted FEV1 of 2.5% (P = 0.046) for the group as a whole. When smoking status and asthma were included in the analysis the effect of time/exposure decreased about 10% and lost statistical significance. on predicted FEF25-75, a decrease of 3.5% (P = 0.035) was observed for the same group and the inclusion of controllers for smoking status and asthma did not affect the effects of time/exposure on pulmonary function parameter. After a 10-year period of work as cooks the participants of the study may present decreases in both predicted FEV1 and FEF25-75 that can reach 20 and 30%, respectively. The present study showed small but statistically significant adverse effects of gas stove exposure on the lung function of professional cooks.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Brazil has an important role in the biomass burning aerosol activity. During the Dry Season (June-September) of 2009 an aerosol profiling campaign was carried out using a backscattering and Raman lidar system in Rio Claro-SP, Brazil (22°23'S and 47°32'W). The main goal of this campaign was to observe the biomass burning aerosol load due to sugarcane crops and also study the air dispersion conditions, planetary boundary and mixed layer daily evolution. In this paper we aim to present the preliminary results of the influence of this type of aerosol over the city of Rio Claro-SP, Brazil and one case study to evaluate the aerosol profile in a biomass burning episode that occurred in July, 2009. On July 15 an intense burning was observed about 300 m away from the lidar location. Throughout the measurements it was observed that the plumes reached up to 900 m, and that there was a time gap between the plumes. The gas analyzers showed a strong influence of this burning as it was noticed in the measurements of CO, NO x and nephelometer, whereas the PM10 did not have due to this burning, possibly because the particulate was deposited further from the emission source, not being detected by the equipment. © Sociedad Española de Óptica.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJETIVOS: estimar as correlações entre os níveis de poluentes atmosféricos e o número de internações por doença respiratória em crianças, em hospital universitário. MÉTODOS: trata-se de um estudo ecológico de série temporal. Os dados sobre poluentes atmosféricos foram obtidos junto à CETESB e os dados sobre internação hospitalar, junto ao SAME do Hospital Universitário de Taubaté, Brasil. O estudo se refere a dados e internação do ano de 2001. Para estudar as correlações dos valores dos poluentes entre si e entre as internações, utilizou-se da técnica de correlação de Pearson. Foram estimados os riscos relativos para internação por doença respiratória comparando os quartis dos agentes poluentes com os valores do primeiro quartil. A significância estatística adotada foi alfa = 5%. RESULTADOS: foram internadas 158 crianças com doença respiratória no ano de 2001 (30% do total de internações no ano). Os poluentes estiveram correlacionados entre si e houve correlação positiva, entre o número de internação e dióxido de enxofre e material particulado; houve aumento de 25% no risco de internação comparando o quarto quartil e o primeiro quartil. CONCLUSÕES: houve correlação positiva entre número de internações por doenças respiratórias e poluentes atmosféricos.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The promotion of good indoor air quality in schools is of particular public concern for two main reasons: (1) school-age children spend at least 30% of their time inside classrooms and (2) indoor air quality in urban areas is substantially influenced by the outdoor pollutants, exposing tenants to potentially toxic substances. Two schools in Curitiba, Brazil, were selected to characterize the gaseous compounds indoor and outdoor of the classrooms. The concentrations of benzene, toluene, ethylbenzene, and the isomers xylenes (BTEX); NO2; SO2; O3; acetic acid (HAc); and formic acid (HFor) were assessed using passive diffusion tubes. BTEX were analyzed by gas chromatography-ion trap mass spectrometry and other collected gasses by ion chromatography. The concentration of NO2 varied between 9.5 and 23 μg m-3, whereas SO2 showed an interval from 0.1 to 4.8 μg m-3. Within the schools, BTEX concentrations were predominant. Formic and acetic acids inside the classrooms revealed intermediate concentrations of 1.5 μg m-3 and 1.2 μg m-3, respectively. © Springer Science + Business Media B.V. 2009.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Taking into account that paracoccidioidomycosis infection occurs by inhalation of the asexual conidia produced by Paracoccidioides spp. in its saprobic phase, this work presents the collection of aerosol samples as an option for environmental detection of this pathogen, by positioning a cyclonic air sampler at the entrance of armadillo burrows. Methods included direct culture, extinction technique culture and Nested PCR of the rRNA coding sequence, comprising the ITS1-5.8S-ITS2 region. In addition, we evaluated one armadillo (Dasypus novemcinctus) as a positive control for the studied area. Although the pathogen could not be isolated by the culturing strategies, the aerosol sampling associated with molecular detection through Nested PCR proved the best method for discovering Paracoccidioides spp. in the environment. Most of the ITS sequences obtained in this investigation proved to be highly similar with the homologous sequences of Paracoccidioides lutzii from the GenBank database, suggesting that this Paracoccidioides species may not be exclusive to mid-western Brazil as proposed so far. © 2013 ISHAM.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The building sector can cause the environmental degradation, by the natural resources consumption, machinery use and natural landscape modifying. The environmental management system (EMS) improves the environmental quality and makes the companies more competitive. So, this work developed an environmental management system in a building site focused on the solid waste and in the development of mitigation proposals for the most significant environmental impacts. To develop this work it was necessary to follow the building site activities; evaluate the solid waste management; identify the law requirements; identify the environmental aspects and impacts; evaluate the environmental impacts; and propose alternatives for mitigating the adverse environmental critical impacts. The main proposals are the reduction of the waste generation in the place that it’s generated; the reuse and correct final disposal of that wastes; the treatment and reuse of the effluent; and the supervising in the trucks and machineries avoiding the oil spilling and the air pollution

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This article aims to analyse the introduction of environmental issues in the context of the production function, which has been referred to as the organisational area to lead corporate environmental management. With that purpose, the theoretical references for corporate environmental management and the necessary alterations in production function have been organised to include environmental aspects, especially in terms of product and process development, quality management, and logistics. Considering that this research field still lacks empirical evidence for Brazilian companies, four case studies were conducted using companies located in the country. The environmental management maturity level of those companies tends to follow the rate with which the environmental issue is introduced in production sub-areas, especially in the product development process. However, in most cases we found that the companies had difficulties in structuring the insertion of the environmental dimension in logistics. The final notes point out the distance observed between what is recommended by international literature and the reality of Brazilian companies in the challenge of making the production function environmentally friendly.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Our society is presently seeing a trend of continuous increase of risk with severe consequences, especially those linked to environmental aspects. It has obligated us to reflect on this production and its effects, either positive or negative, and, after a long reflection, to think about the adopted model of civilization and the possibilities of changing such a model. The educational institution is among the social departments responsible for this revision process, since it represents one possibility to promote a more critical vision from society, providing it with tools needed for a more responsible action. However, schools are dominated by a traditional work, which does not allow for enough and proper attention to these relevant and current questions, and which involve a critical analysis of the conceptions and values established by our civilization, resulting in the present patterns of science-technology-society relations and their influence on the environment and health. Several research works have indicated a diversity of barriers that obstruct this necessary change. Since formal education plays an important role in the education of society for this theme, in this paper the possibilities and difficulty dealing with this problem are discussed, focusing on the question of teacher education, based on investigations related to teacher education programs for environmental education. The data collected show the urgency for introducing this theme in teacher training programs, taking into account the fact that educators have their own conceptions, values and attitudes that should be considered in these programs.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The role of air pollution as a health risk factor is of special interest. Numerous toxic pollutants, such as nickel, are being released to the environment as a result of combustion of fossil fuels, crude oil, and coal. Nickel in the atmosphere can be combined with other environmental pollutants, producing various nickel compounds, which have varying animal toxicity. A rat biossay validated for the identification of toxic effects of nickel revealed increased serum activities of total lactate dehydrogenase (LDH) and alanine transaminase (ALT) in rats that received intratracheal injection of Ni2+ in .09% saline solution of NiCl2. The total LDH activity was also increased in the heart, and the isoenzyme pattern showed the LDH1/LDH2 ratio elevated to greater than 1. We conclude that intratracheal administration of nickel induced cardiac and hepatic damage. The development of cardiac and hepatic damage and of increased enzymes' activities was only demonstrated when nickel had accumulated in these tissues, indicating that nickel depot is essential to its toxicity. Intratracheal administration of NiCl2 induced changes in LDH and ALT activities.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Microbial contamination of an enclosed area may come from outside or be generated within the area itself. In the study described here, bioaerosol levels in hospital air were quantified and related to those found in the air outside, taking into account some of the environmental variables that affect air quality, such as the number of occupants of a room and the type of ventilation. Airborne bacteria were collected for five minute by blowing air at 500 L min -1 in high speed jets on to the surface on plates culture in a single-stage bioaerosol impactor. The mean viable count of bacteria in the air outside in the hospital, São Paulo State, was 77 ± 4 CFU m -3, while in the air inside the hospital it was 302 ± 260 CFU m-3. The operating theatre was the only space sampled with a controlled environment and, after orthopedic surgery, it had the highest bioaerosol count recorded (867 ± 482 CFU m-3). In the enclosed environments, nine bacterial species were identified. Despite the difficulty in establishing precise numbers of bacteria in the bioaerosols in hospital environments, the values obtained demonstrate a need to instigate suitable programs to keep the microbial density low in these environments, and eliminate microorganisms presenting a significant risk to their occupants. It is also recommended that such programs include the monitoring of hospital air, with the aim of defining standards for acceptable numbers of bacteria in the bioaerosol.