68 resultados para Adobe RGB

em Repositório Institucional UNESP - Universidade Estadual Paulista "Julio de Mesquita Filho"


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of this study was to describe a new technique by using Adobe Photoshop CS (San Jose, CA) image-analysis software to evaluate the radiographic changes of chronic periapical lesions after root canal treatment by digital subtraction radiography. Thirteen upper anterior human teeth with pulp necrosis and radiographic image of chronic periapical lesion were endodontically treated and radiographed 0, 2, 4, and 6 months after root canal treatment by using a film holder. The radiographic films were automatically developed and digitized. The radiographic images taken 0, 2, 4, and 6 months after root canal therapy were submitted to digital subtraction in pairs (0 and 2 months, 2 and 4 months, and 4 and 6 months) choosing image, calculation, subtract, and new document tools from Adobe Photoshop CS image-analysis software toolbar. The resulting images showed areas of periapical healing in all cases. According to this methodology, the healing or expansion of periapical lesions can be evaluated by means of digital subtraction radiography by using Adobe Photoshop CS software.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This work deals with the Priestley-Taylor model for evapotranspiration in different grown stages of a bean crop. Priestley and Taylor derived a practical Formulation for energy partitioning between the sensible and latent heat fluxes through the a parameter. Bowen ratio energy balance (BREB) was carried out for daily sensible and latent heat flux estimations in three different crop stages. Mean daily values of Priestley-Taylor a parameter were determined for eleven days during the crop cycle. Diurnal variation patterns of a are presented for the growing, flowering and graining periods. The mean values of 1.13 +/- 0.33, 1.26 +/- 0.74, 1.22 +/- 0.55 were obtained for a day in the growing, in the flowering and for graining periods, respectively. Eleven days values of a are shown and gave a mean value of 1.23 +/- 0.10 which agree on the reported literature.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Few quantitative data exist on pupil diameter, particularly in children. In this article we describe an analysis of pupil diameter and pupil area in normal preschool children during attentive gaze (AG) and spontaneous gaze (SG) using digital imaging. The pupil diameter and pupil area of 200 preschool children aged 4 to 6 years were evaluated. The images were recorded with a digital camera, transferred to a computer, processed by movie software and submitted to the Invert filter of Adobe Photoshop (R) software. Three consecutive measures of pupil diameter and pupil area were taken for both eyes during AG and SG. Arithmetic means of each parameter were calculated and data were expressed in millimeters. Mean pupil diameter was similar for both eyes, presenting values of 4.9 mm during AG and 4.1 mm during SG. Mean pupil area was also similar for both eyes, presenting values of 15.6 mm(2) and 9.1 mm(2) during AG and SG, respectively. There were no differences between boys and girls. However, 6-year-old children showed lower pupil diameter and area under both evaluation conditions.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of this study was to analyze the color alterations performed by the CIE L*a*b* system in the digital imaging of shade guide tabs, which were obtained photographically according to the automatic and manual modes. This study also sought to examine the observers' agreement in quantifying the coordinates. Four Vita Lumin Vaccum shade guide tabs were used: A3.5, B1, B3 and C4. An EOS Canon digital camera was used to record the digital images of the shade tabs, and the images were processed using Adobe Photoshop software. A total of 80 observations (five replicates of each shade according to two observers in two modes, specifically, automatic and manual) were obtained, leading to color values of L*, a* and b*. The color difference (AE) between the modes was calculated and classified as either clinically acceptable or unacceptable. The results indicated that there was agreement between the two observers in obtaining the L*, a* and b* values related to all guides. However, the B1, B3, and C4 shade tabs had AE values classified as clinically acceptable (Delta E = 0.44, Delta E = 2.04 and Delta E = 2.69, respectively). The A3.5 shade tab had a AE value classified as clinically unacceptable (Delta E = 4.17), as it presented higher values for luminosity in the automatic mode (L* = 54.0) than in the manual mode (L* = 50.6). It was concluded that the B1, B3 and C4 shade tabs can be used at any of the modes in digital camera (manual or automatic), which was a different finding from that observed for the A3.5 shade tab.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objectives: The aim of this study was to compare two methods for the evaluation of periapical lesion changes following endodontic therapy (digital subtraction technique and morphometric analysis) by outlining the radiolucent area.Methods: 13 human anterior teeth with pulp necrosis and chronic periapical lesions were used. Periapical radiographs were taken immediately after endodontic therapy (0) and then 2 months, 4 months and 6 months post treatment, using an intraoral radiographic film holder stabilized with impression material. The films were processed in a standard manner and the digitized images were submitted to digital subtraction using Adobe Photoshop 6.0. New bone formation or bone resorption areas were then measured. In the morphometric analysis, the periapical lesions were outlined using VixWin 2000 and the area (in square millimetres) was recorded. The obtained data were submitted to agreement analysis for comparison of the two techniques.Results: There was no correlation between the areas of radiographic changes detected by digital subtraction and periapical lesion outline (r=0.02-0.45). The new bone formation areas observed by digital subtraction presented higher values, with bone changes being especially evident in the 2 month follow-up radiographs, which suggests a higher sensitivity for this method.Conclusions: Both methods are suitable for the evaluation of periapical lesion changes, but the digital subtraction technique is more sensitive for detecting radiographic periapical changes. Dentomaxillofacial Radiology (2009) 38, 438-444. doi: 10.1259/dmfr/53304677

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Multicolor and white light emissions have been achieved in Yb3+, Tm3+ and Ho3+ triply doped heavy metal oxide glasses upon laser excitation at 980 nm. The red (660 nm), green (547 nm) and blue (478 nm) up conversion emissions of the rare earth (RE) ions triply doped TeO2-GeO2-Bi2O3-K2O glass (TGBK) have been investigated as a function of the RE concentration and excitation power of the 980 nm laser diode. The most appropriate combination of RE in the TGBK glass host (1.6 wt% Yb2O3, 0.6 wt% Tm2O3 and 0.1 wt% Ho2O3) has been determined with the purpose to tune the primary colors (RGB) respective emissions and generate white light emission by varying the pump power. The involved infrared to visible up conversion mechanisms mainly consist in a three-photon blue up conversion of Tm3+ ions and a two-photon green and red up conversions of Ho3+ ions. The resulting multicolor emissions have been described according to the CIE-1931 standards. (C) 2011 Elsevier B.V. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objectives: To compare simulated periodontal bone defect depth measured in digital radiographs with dedicated and non-dedicated software systems and to compare the depth measurements from each program with the measurements in dry mandibles.Methods: Forty periodontal bone defects were created at the proximal area of the first premolar in dry pig mandibles. Measurements of the defects were performed with a periodontal probe in the dry mandible. Periapical digital radiographs of the defects were recorded using the Schick sensor in a standardized exposure setting. All images were read using a Schick dedicated software system (CDR DICOM for Windows v.3.5), and three commonly available non-dedicated software systems (Vix Win 2000 v.1.2; Adobe Photoshop 7.0 and Image Tool 3.0). The defects were measured three times in each image and a consensus was reached among three examiners using the four software systems. The difference between the radiographic measurements was analysed using analysis of variance (ANOVA) and by comparing the measurements from each software system with the dry mandibles measurements using Student's t-test.Results: the mean values of the bone defects measured in the radiographs were 5.07 rum, 5.06 rum, 5.01 mm and 5.11 mm for CDR Digital Image and Communication in Medicine (DICOM) for Windows, Vix Win, Adobe Photoshop, and Image Tool, respectively, and 6.67 mm for the dry mandible. The means of the measurements performed in the four software systems were not significantly different, ANOVA (P = 0.958). A significant underestimation of defect depth was obtained when we compared the mean depths from each software system with the dry mandible measurements (t-test; P congruent to 0.000).Conclusions: the periodontal bone defect measurements in dedicated and in three non-dedicated software systems were not significantly different, but they all underestimated the measurements when compared with the measurements obtained in the dry mandibles.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objectives: the purpose of this study was to evaluate the correlation between central incisor form and face form in 4 racial groups and to investigate if there was agreement among experts in categorizing the central incisor forms. Method and Materials: A total of 160 subjects (40 whites, 40 mulattos, 40 blacks, and 40 Asians) ranging from 18 to 33 years of age were selected. Digital photographic records were made, 1 full-face and 1 intraoral view of the maxillary right central incisor. The outline tracings of the tooth and face images were obtained using Adobe Photoshop 5.0 software. The outline tracings were printed in distinct transparencies, and 3 prosthodontists determined if there was correspondence between the tooth and the face forms by superimposition of the transparencies. If there was disagreement among the prosthodontists' evaluations, the prevalent decision was considered. The experts also classified the central incisor forms into square, ovoid, tapering, or combination at 2 different sessions. At the first session, no instructions were given. At the second session, the prosthodontists were instructed to follow Williams' method of classification. Results: A correspondence between tooth and face forms was found in 23.75% of all cases. Agreement on the tooth form classifications among the prosthodontists occurred in 30.62% of all cases at the first session and 24.37% at the second session. Conclusion: There is not a highly defined correlation between central incisor form and face form in any racial group studied. In addition, the experts were not in fair agreement in categorizing tooth forms.