223 resultados para Acurácia Posicional
em Repositório Institucional UNESP - Universidade Estadual Paulista "Julio de Mesquita Filho"
Resumo:
The goal of this paper is to present a methodology for quality control of horizontal geodetic networks through robustness and covariance analysis. In the proposed methodology, the positional accuracy of each point is estimated by a possible bias in their position (based on robustness analysis), in addition to its own positional precision (uncertainty) (through covariance analysis), being a measure independently from the choice of the datum. Besides presenting the theoretical development of the method, its application is demonstrated in a numerical example. The results indicate that, in general, the greater the distance of an unknown point to the control(s) point(s) of the network, the greater is the propagation of random errors on this unknown point, and the smaller the number of redundant observations around a unknown point, the greater the influence of possible (undetected) non-random errors on this point.
Resumo:
Accuracy concepts that involve systematic and random effects and precision, that involves only random ones, are reviewed in this paper. An objective discussion is presented based on the definitions that appear in the literature, followed by examples that may be enough to clarify some concepts and allow the extension for other applications. The discussion presented aims at raising eventual inconsistencies in the interpretations so as to provide better possibilities of use for those involved with this topic, which is fundamentally important in the quality analysis of cartographic, geodetic and remote sensing or photogrammetric products.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Objective: To determine the accuracy of the variables related to the fixed-height stair-climbing test (SCT) using maximal oxygen uptake (V̇O 2 max) as the gold standard. Methods: The SCT was performed on a staircase consisting of 6 flights (72 steps; 12.16 m total height), with verbal encouragement, in 51 patients. Stair-climbing time was measured, the variables 'work' and 'power' also being calculated. The V̇O2 max was measured using ergospirometry according to the Balke protocol. We calculated the Pearson linear correlation (r), as well as the values of p, between the SCT variables and V̇O2 max. To determine accuracy, the V̇O 2 max cut-off point was set at 25 mL/kg/min, and individuals were classified as normal or altered. The cut-off points for the SCT variables were determined using the receiver operating characteristic curve. The Kappa statistic (k) was used in order to assess concordance. Results: The following values were obtained for the variable 'time': cut-off point = 40 s; mean = 41 ± 15.5 s; r = -0.707; p < 0.005; specificity = 89%; sensibility = 83%; accuracy = 86%; and k = 0.724. For 'power', the values obtained were as follows: cut-off point = 200 w; mean = 222.3 ± 95.2 w; r = 0.515; p < 0.005; specificity = 67%; sensibility= 75%; accuracy = 71%; and k = 0.414. Since the correlation between the variable 'work' and V̇O2 max was not significant, that variable was discarded. Conclusion: Of the SCT variables tested, using V̇O2 max as the gold standard, the variable 'time' was the most accurate.
Resumo:
The aim of this investigation was to evaluate four reference methods to estimate evapotranspiration (Makkink, Hargreaves, Class A pan and Radiation), compared tb Penman-Monteith method, that is considered standard by the Food and Agricultural Organization of the United Nations (FAO). Errors due to variable measurements in the reference evapotranspiration estimate were taken into consideration. The research was developed in an experimental area of the Department of Rural Engieering of the School of Agricultural and Veterinarian Sciences, Campus of Jaboticabal, São Paulo State University. An automated weather station was used and it was equipped with sensors to measure global and net radiation, temperature, relative humidity, and wind speed. The aftermath showed a better adjustment to Hargreaves. Makkink, Class A pan and Radiation methods are different from Penman-Monteith, therefore, they cannot be compared. To evaluate methods to estimate evapotranspiration and avoid possible evaluation errors, ETo estimate errors must be considered.
Resumo:
Introduction: The autologous serum skin test (ASST) may suggest an autoimmune etiology in chronic urticaria (CU). A new laboratory technique called basophil activation test (BAT) has been currently employed for its diagnosis. Objective: To analyze ASST in relation to BAT as well as to evaluate interleukin 3 (IL3) receptors (CD123) and non-specific immunoglobulin G (IgG) autoantibodies bound to basophils in patients with chronic urticaria. Methods: We studied 33 adults with CU and mean age of 42.5 + 14 years. After stimulation by serum from patients with CU, CD63 expression on basophils from one atopic donor was analyzed by flow cytometry. Furthermore, we investigated CD123 and IgG autoantibody expressions. Results: The odds ratio (OR) between ASST and BAT was 1.00 (95% confidence interval [CI]: 0.22 to 4.5). The ASST for autoimmune CU diagnosis showed an accuracy of 54.5%, sensitivity of 66%, specificity of 33%, positive predictive value of 63%, and negative predictive value of 36%. There was no statistical difference between the studied groups as to mean non-specific IgG and CD123 expressions (for a p < 0.05). Discussion: This study demonstrated that ASST has low accuracy in the diagnosis of autoimmune CU. Concerning other analyzed aspects, there was no statistical difference between positive ASST and negative ASST. Conclusions: Due to insufficient studies in this area and the relevance of this issue, further investigation is required.
Resumo:
PURPOSE: To compare the diagnostic accuracy of sonohysterography (HSN) and conventional transvaginal ultrasound (USG) in assessing the uterine cavity of infertile women candidate to assisted reproduction techniques (ART). METHODS: Comparative cross-sectional study with 120 infertile women candidate to ART, assisted at Centro de Reprodução Assistida (CRA) of Hospital Regional da Asa Sul (HRAS), Brasília-DF, from August 2009 to November 2010. Sonohysterography was performed with saline solution infusion in a close system. The sonohysterography finding was compared to previous USG results. The uterine cavity was considered abnormal whenthe endometrium was found to be thicker than expectedduring the menstrual cycle and whenan endometrial polyp, a submucous myoma and an abnormal shape of the uterine cavity were observed. The statistical analysis was doneusing absolute frequencies, percentage values and the χ 2, with the level of significance set at5%. RESULTS:HSN revealed that 92 (76.7%) infertile women candidate to ARThad anormal uterine cavity, while 28 (23.3%) had the following abnormalities: 15 polyps (12.5%).
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Pós-graduação em Ciências Cartográficas - FCT
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Pós-graduação em Agronomia (Ciência do Solo) - FCAV
Resumo:
Pós-graduação em Fisiopatologia em Clínica Médica - FMB
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Pós-graduação em Doenças Tropicais - FMB
Resumo:
There is in the literature a divergent description between lexical knowledge and word production accuracy. The aims of this study were: (a) to investigate the influence (effect) of the word lexical knowledge over production accuracy; (b) in case there is, to characterize acoustically this interference. Eight children (5-6 years old) with typical development language participated of this study. The methodological procedure consisted of: (a) survey of the children lexical knowledge concerning to IAFAC’s words; (b) recordings of the IAFAC’s words; (c) identifi cation and characterization of the linguistic cues, by acoustic analysis, in the IAFAC’s word production in function of the different knowledge degrees. Our results suggest a negative correlation (r=-0,13, p=0,000) between lexical knowledge and presence of the linguistics cues in word’s production. However, the linguistics cues refer to hesitative cues instead of phonological errors. Implications of these results for clinical practicing are discussed.