298 resultados para Activated sludge. Flocs. Aeration intensity. Dissolved oxygen. Removal efficiency
em Repositório Institucional UNESP - Universidade Estadual Paulista "Julio de Mesquita Filho"
Resumo:
In this study it was evaluated the efficiency of the treatment of wet-processed coffee wastewater in upflow anaerobic sludge blanket (UASB) reactors in two stages, in bench scale, followed by post-treatment with activated sludge in batch. The first UASB reactor was submitted to an hydraulic retention time (HRT) of 6.2 d and organic loading rates (OLR) of 2.3 and 4.5g CODtotal (L d)-1, and the second UASB reactor to HRT of 3.1 d with OLR of 0.4 and 1.4g CODtotal (L d)-1. The average values of the affluent CODtotal increased from 13,891 to 27,926mg L-1 and the average efficiencies of removal of the CODtotal decreased from 95 to 91%, respectively, in the UASB reactors in two stages. The volumetric methane production increased from 0.274 to 0.323L CH4 (L reactor d)-1 with increment in the OLR. The average concentrations of total phenols in the affluent were of 48 and 163mg L-1, and the removal efficiencies in the UASB reactors in two stages of 92 and 90%, respectively, and increased to 97% with post-treatment. The average values of the removal efficiencies of total nitrogen and phosphorus were of 57 to 80% and 44 to 60%, respectively, in the UASB reactors in two stages and increased to 91 and 84% with the post-treatment.
Resumo:
An amperometric oxygen sensor based on a polymeric nickel-salen (salen = N,N'-ethylene bis(salicylideneiminato)) film coated platinum electrode was developed. The sensor was constructed by electropolymerization of nickel-salen complex at platinum electrode in acetonitrile/tetrabutylammonium perchlorate by cyclic voltammetry. The voltammetric behavior of the sensor was investigated in 0.5 mol L-1 KCl solution in the absence and presence of molecular oxygen. Thus, with the addition of oxygen to the solution, the increase of cathodic peak current (at -0.25 V vs. saturated calomel electrode (SCE)) of the modified electrode was observed. This result shows that the nickel-salen film on electrode surface promotes the reduction of oxygen. The reaction can be brought about electrochemically, where the nickel(II) complex is first reduced to a nickel(I) complex at the electrode surface. The nickel(I) complex then undergoes a catalytic oxidation by the molecular oxygen in solution back to the nickel(II) complex, which can then be electrochemically re-reduced to produce an enhancement of the cathodic current. The Tafel plot analyses have been used to elucidate the kinetics and mechanism of the oxygen reduction. A plot of the cathodic current vs. the dissolved oxygen concentration for chronoamperometry (fixed potential = -0.25 V vs. SCE) at the sensor was linear in the 3.95-9.20 mg L-1 concentration range and the concentration limit was 0.17 mg L-1 O-2. The proposed electrode is useful for the quality control and routine analysis of dissolved oxygen in commercial samples and environmental water. The results obtained for the levels of dissolved oxygen are in agreement with the results obtained with a commercial O-2 sensor. (C) 2012 Elsevier B.V. All rights reserved.
Resumo:
An amperometric oxygen sensor based on a polymeric nickel-salen (salen = N,N '-ethylenebis(salicydeneiminato)) film coated platinum electrode was developed. The sensor was constructed by electropolymerization of nickel-salen complex at a platinum electrode in acetonitrile/tetrabuthylamonium perchlorate by cyclic voltammetry. The voltammetric behavior of the modified electrode was investigated in 0.5 mol L-1 KCl solution in the absence and presende of molecular oxygen. A significant increased of cathodic peak current (at -0.20 vs. SCE) of the modified electrode with addition of oxygen to the solution was observed. This result shows that the nickel-salen film on the surface of the electrode promotes the reduction of oxygen. The reaction can be brought about electrochemically where in the nickel(II) complex is first reduced to a nickel(I) complex at the electrode surface. The nickel(I) complex then undergoes a catalytic oxidation by the oxygen molecular in solution back to the nickel(II) complex, which can then be electrochemically re-reduced to produce an enhancement of the cathodic current. The plot of the cathodic current versus the dissolved oxygen concentration for chronoamperometry (potential fixed = -0.20 V) at the sensor was linear in the concentration range of 3.95 to 9.20 mg L-1 with concentration limit of 0.17 mg L-1 O-2. The modified electrode proposed is useful for the quality control and routine analysis of dissolved oxygen in commercial water and environmental water samples. The results obtained for the levels of dissolved oxygen are in agreement with the results obtained with an O-2 commercial sensor. (C) 2011 Published by Elsevier Ltd.
Resumo:
A comparison of the thermal regime and oxygen distribution patterns of some Brazilian reservoirs was made. A strong latitudinal dependence of surface temperature, annual mean and annual range was found. Except for Tucurui Reservoir, a reservoir of the Equatorial zone, the lowest surface temperature of the year in the other compared reservoirs was observed from June to August while the highest extended from October to February. The decreasing trend of annual mean temperatures and thermal ranges was due to the increasing seasonal variability of insolation with the latitude. A positive relationship between the increase on thermal surface-bottom differences and the depth of water column was found for reservoirs of similar latitudes. A long thermal stratification (around four months) was evidenced in the lacustrine zone of reservoirs with a residence time higher than 40 days. Low fluctuation (<2%) of the annual variability of heat contents was observed for the Tucurui Reservoir, while in das Garcas Reservoir a manmade lake located in the frontier between tropical and temperate regions, the annual coefficient of variation attained 13%. Concerning the heat budgets, the value for the Tucurui Reservoir was two times higher than in das Garcas Reservoir. Both the morphometric and climatological factors affected the heat contents of the two compared reservoirs. In deep eutrophic reservoirs, a significant reduction on the oxygen concentrations in the hypolimnetic zone was frequently observed. In some oligotrophic stratified reservoirs, a decrease on oxygen with depth occurred when the temperature of the hypolimnion was higher than 20 degrees C and caused a biochemical oxygen demand. In das Garcas Reservoir, the actual oxygen deficits ranged from 0.40 to 1.52 mg.O-2.cm(-2) and appear to be linked to oxygen consumption after the senescence of Microcystis aeruginosa populations in the spring. But, other factors such as the allochthonous loads of organic matter also had an important role on the oxygen balance of das Garcas Reservoir.
Resumo:
The procedure for formaldehyde analysis recommended by the National Institute for Occupational Safety and Health (NIOSH) is the Chromotropic acid spectrophotometric method, which is the one that uses concentrated sulphuric acid. In the present study the oxidation step associated with the aforementioned method for formaldehyde determination was investigated. Experimental evidence has been obtained indicating that when concentrated H2SO4 (18 mol l(-1)) is used (as in the NIOSH procedure) that acid is the oxidizing agent. on the other hand, oxidation through dissolved oxygen takes place when concentrated H2SO4 is replaced by concentrated hydrochloric (12 mol l(-1)) and phosphoric (14.7 mol l(-1)) acids as well as by diluted H2SO4 (9.4 mol l(-1)). Based on investigations concerning the oxidation step, a modified procedure was devised, in which the use of the potentially hazardous and corrosive concentrated H2SO4 was eliminated and advantageously replaced by a less harmful mixture of HCl and H2O2. (C) 2003 Elsevier B.V. B.V. All rights reserved.
Resumo:
The autoxidation of [Ni-II(cyclam)](2+) (cyclam = 1,4,8,11-tetraazacyclotetradecane) and Ni(II)tetraglycine, accelerated by S-IV is studied spectrophotometrically by following the formation of Ni-III complexes.
Resumo:
In industrial processes using aqueous solutions, corrosion of metal surfaces may occur at various locations. Much of the damage to steam generators and boilers is caused by corrosion. Dissolved oxygen in water is one of the most potent corrosion-causing factors, and therefore oxygen should be eliminated from steam-generating systems' feedwater. Chemical reduction, by reagents such as hydrazine or organic compounds, generally is used for the deoxygenation of water. This article reviews the major oxygen scavengers currently available.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Estudou-se o reuso de água de um sistema composto por estação de tratamento de esgoto (ETE) com aeração prolongada e lodo ativado, e em uma estação compacta de tratamento de água (ECTA) de uma indústria metalúrgica. Os processos para obtenção da água de reuso foram: microbiológico e físico-químico. O esgoto doméstico foi bombeado para a ETE, onde houve formação de flocos biológicos e água clarificada. Avaliou-se a eficiência do processo microbiológico da ETE mediante a remoção de demanda bioquímica de oxigênio (DBO), demanda química de oxigênio (DQO) e sólidos sedimentáveis (SS). A eficiência do processo físico-químico de clarificação e desinfecção foi avaliada mediante análises de pH, turbidez, cor, contagem de bactérias heterotróficas aeróbias, cloro livre, dureza, alcalinidade, cloretos, sulfatos, sólidos totais dissolvidos (STD). Na água de reuso além desses parâmetros avaliou-se a toxicidade aguda ao microcrustáceo Daphnia similis.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
O objetivo deste trabalho foi monitorar o desempenho de remoção de nitrogênio amoniacal no tratamento das águas residuárias da produção intensiva de tilápia nilótica em sistema com recirculação de água. O sistema foi constituído por um sedimentador convencional e um reator aeróbio de leito fluidizado trifásico com circulação, operados com tempos de detenção hidráulica de 176.4 e 11.9 minutos respectivamente. O meio suporte utilizado no reator foi o carvão ativado granular com densidade aparente de 1.64 g/cm3 e tamanho efetivo de 0.34 mm; a concentração do meio suporte no reator foi mantida constante em 80 g/L. A eficiência média de remoção do nitrogênio amoniacal total foi de 41.2%. O sistema avaliado é uma alternativa efetiva para o reuso da água em sistemas de recirculação para aqüicultura. Embora a variabilidade das concentrações do nitrogênio amoniacal afluente cujo valor médio foi de 0.136 mg/L, o efluente do reator conservou as características de qualidade da água estáveis, com concentrações médias de nitrogênio amoniacal de 0.079 mg/L e do oxigênio dissolvido de 6.70 mg/L, recomendáveis para a criação dos peixes e nas faixas de valores permitidos pela legislação Brasileira (Resolução CONAMA No. 357 de março 5 de 2005) para lançamento de efluentes finais nos corpos de água receptores.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
The effects of artificial substrate and night-time aeration on the culture of Macrobrachium amazonicum were evaluated in 12 ponds stocked with 45 prawns m-2. A completely randomized design in 2 × 2 factorial scheme with three replicates was used. The combination of factors resulted in four treatments: with substrate and aeration (SA), with substrate and without aeration (SWA), without substrate and with aeration (WSA) and without substrate and aeration (WSWA). The presence of substrate in SA and SWA treatments reduced suspended particles (seston) by ~17.3% and P-orthophosphate by ~50%. The use of aerator (WSA and SA treatments) significantly (P < 0.05) increased the concentration of dissolved oxygen, suspended particles and nutrients in the pond water. These results indicate that the effect of substrate on turbidity and total suspended solids (TSS) values is opposite to the effect of the aerator. The aerators in semi-intensive grow-out M. amazonicum farming lower water quality because they increased the amount of detritus and nutrients in the pond water. On the other hand, the use of artificial substrate reduces turbidity values, chlorophyll a, TSS and P-orthophosphate concentrations. Therefore, the combination of substrate addition and night-time aeration is not interesting because they have opposite effects. © 2013 John Wiley & Sons Ltd.
Resumo: