10 resultados para Acoustic properties.

em Repositório Institucional UNESP - Universidade Estadual Paulista "Julio de Mesquita Filho"


Relevância:

70.00% 70.00%

Publicador:

Resumo:

The complex dynamic Young's modulus of ceramic Nd2-xCexCuO4 with x = 0, 0.05 and 0.20 has been measured from 1.5 to 100 K at frequencies of 1 - 10 kHz. In the undoped sample the modulus starts decreasing below similar to 20 K, instead of approaching a constant value as in a normal solid. The modulus minimum has been interpreted in terms of paraelastic contribution from the relaxation of the Nd3+ 4f electrons between the levels of the ground state doublet, which is split by the interaction with the antiferromagnetically ordered Cu sublattice. The value of the splitting is found to be 0.34 meV, in excellent agreement with inelastic neutron scattering, infrared and specific heat experiments. With doping, the anomaly shifts to lower temperature and decreases in amplitude, consistently with a reduction of the local field from the Cu sublattice. (C) 2003 Elsevier B.V. Ltd. All rights reserved.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Anelastic spectroscopy (internal friction and the dynamic modulus) was measured by means of a torsion pendulum at 3-12 Hz, in the range of 100-300 K, for a KAP metaphosphate glass. Two thermally activated internal friction peaks appeared at ∼190 and ∼250 K. These peaks were attributed to the behavior of potassium ions (high temperature) and to hydrogen (low temperature). Dynamic modulus showed a gradual decrease with increasing temperature in the range studied for all compositions. © 2006 Elsevier B.V. All rights reserved.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Pós-graduação em Biologia Animal - IBILCE

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Ultrasound is the term that describes the sound waves with higher frequencies than human hearing. Ultrasound used in medical diagnosis is a modality based on the use of sound energy and the acoustic properties of the various parts of the body to produce images of stationary and moving tissues. However, despite the ease of use and security that this modality offers for not using ionizing radiation, one should ensure the accuracy and optimum performance of the equipment, which results in precise diagnoses. To accomplish that, periodic quality control tests must be performed, which include: physical and mechanical inspection of the equipment, image uniformity, depth of penetration/visualization, accuracy of distances, axial and lateral resolution, dead zone and doppler sensitivity. This work intends to study a computerized method for calculating the depth of penetration of ultrasound, comparing it to the observerdependent method currently used. The images were collected during the quality control tests of ultrasound equipment. The results of the comparison between the visual and computerized methods were not conclusive for selecting the safest methodology for obtaining the depth of visualization

Relevância:

30.00% 30.00%

Publicador:

Resumo:

O trato olivococlear medial realiza o controle eferente das células ciliadas externas, regulando as contrações lentas e atenuando as rápidas. Com a pesquisa da amplitude das emissões otoacústicas sem e com estimulação acústica contra, ipsi ou bilateralmente, é possível estimar as condições desse trato, uma vez que o efeito resultante de redução/supressão das emissões indica seu funcionamento. O envelhecimento implica em diminuição da atividade do sistema auditivo central, em função da degeneração das estruturas envolvidas nas habilidades auditivas. OBJETIVO: O objetivo foi investigar o efeito da idade na atividade do trato sobre a cóclea, com a análise da amplitude das emissões com estimulação acústica contralateral. MATERIAL E MÉTODO: A casuística foi composta por 75 indivíduos agrupados conforme a idade. A metodologia foi o modo convencional, com clique linear e o ruído branco. ESTUDO DE CASO: A análise considerou a resposta das orelhas e a comparação entre os grupos. RESULTADOS: Os resultados revelam diferenças estatisticamente significantes entre o response das emissões sem e com estimulação acústica contralateral, nos indivíduos (20 a 39 anos). O efeito redução/supressão das emissões diminui com a idade (quarta década). CONCLUSÃO: O envelhecimento prejudica a efetividade da atividade do trato.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

An artificial neural network (ANN) approach is proposed for the detection of workpiece `burn', the undesirable change in metallurgical properties of the material produced by overly aggressive or otherwise inappropriate grinding. The grinding acoustic emission (AE) signals for 52100 bearing steel were collected and digested to extract feature vectors that appear to be suitable for ANN processing. Two feature vectors are represented: one concerning band power, kurtosis and skew; and the other autoregressive (AR) coefficients. The result (burn or no-burn) of the signals was identified on the basis of hardness and profile tests after grinding. The trained neural network works remarkably well for burn detection. Other signal-processing approaches are also discussed, and among them the constant false-alarm rate (CFAR) power law and the mean-value deviance (MVD) prove useful.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

It is very important for the building of the SAW devices to study dielectric and ferroelectrics properties because every SAW device is based in piezoelectric effect that it is made up to transform an electric sign in the mechanical or acoustic sign and a mechanical or acoustic sign in an electric sign. Thus, the purpose of the present work is to prepare PbZr 0,53Ti0.47O3 (PZT) and PbTiO3 (PT) thin films on the Si (100) substrates across spin-coating using a chemical method based in polymeric precursors. After conventional treatment in the furnace, the films were characterized by impedance spectroscopy and hysteresis loops to know its dielectric and ferroelectric properties.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Composites made of calcium modified lead titanate ceramic powder and poly (ether-ether-ketone) high performance polymer matrix were prepared in the film form using a hot press. The acoustic and electromechanical properties of the composites have been determined using the ultrasonic immersion technique and piezoelectric spectroscopy, respectively. The composite film with 60 - 40 vol.% PTCa/PEEK was tested as acoustic emission detector. Preliminary results shown that the piezo composite can be used as sensor to evaluate the behavior of materials.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The continuous technological advances require materials with properties that conventional material cannot display. Material property combinations are being the focus to the development of composite materials, which are considered a multiphase material that exhibits properties of the constituent phases. One interesting material to be studied as sensing material is the composite made of ferroelectric ceramic and polymeric matrix as a two-phases composite material. In that case, the combinations properties intended are the high piezo and pyroelectric activities of the dense ceramic with the impact resistance, flexibility, formability and low densities of the polymer. Using the piezoelectric property of the composite film, it can be used to detect acoustic emission (AE), which is a transient elastic wave generated by sudden deformation in materials under stress. AE can be applied for evaluating the health of structures in a nondestructive way and without any lapse of time. The preliminary result indicates that the composite Pz34/PEEK can be used as sensing material for nondestructive evaluation. ©2009 IEEE.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Acoustic techniques have been used for many years to find and locate leaks in buried water distribution systems. Hydrophones and accelerometers are typically used as sensors. Although geophones could be used as well, they are not generally used for leak detection. A simple acoustic model of the pipe and the sensors has been proposed previously by some of the authors of this paper, and their model was used to explain some of the features observed in measurements. However, simultaneous measurements of a leak using all three sensor-types in controlled conditions for plastic pipes has not been reported to-date and hence they have not yet been compared directly. This paper fills that gap in knowledge. A set of measurements was made on a bespoke buried plastic water distribution pipe test rig to validate the previously reported analytical model. There is qualitative agreement between the experimental results and the model predictions in terms of the differing filtering properties of the pipe-sensor systems. A quality measure for the data is also presented, which is the ratio of the bandwidth over which the analysis is carried out divided by the centre frequency of this bandwidth. Based on this metric, the accelerometer was found to be the best sensor to use for the test rig described in this paper. However, for a system in which the distance between the sensors is large or the attenuation factor of the system is high, then it would be advantageous to use hydrophones, even though they are invasive sensors.