86 resultados para Accident reconstruction.

em Repositório Institucional UNESP - Universidade Estadual Paulista "Julio de Mesquita Filho"


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Facial injuries with the retention of foreign bodies inside the tissues, both in soft and hard ones, can cause major functional and aesthetic damage. Among the different etiological agents, cutting tools, fragments of a firearm, the splinter of wood, steel, or iron, launched by misuse, or even caused by defects in equipment, are the main cause of these injuries. The aim of this study was to discuss the peculiarity of the multidisciplinary approach in caring of a 33-year-old man, victim of an accident at work, by the rupture of an emery disc and consequent penetration of the fragments in violation of the tissues in the orbital and zygomatic region of the left side, with perforation of the eyeball and orbital-zygomatic fracture. Urgent treatment consisted of debridement of wounds, bleeding control, removal of foreign bodies, fracture reduction with rigid internal fixation, and suture, performed by the oral and maxillofacial surgical team. Reconstruction of orbital tissues by the ophthalmology team consisted of suture of the injuries. About 1 month after the trauma, phthisis bulbi was noted, and the patient underwent a new procedure under general anesthesia for eye evisceration and installation of an alloplastic prosthesis associated with the homogenous sclera. Facial harmony was restored, especially in aesthetics and function of the zygomatic-orbital complex.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Hand deformities affect aesthetics function of hand severely compromised and also cause psychological disturbances. This report describes the fabrication of a silicone finger prosthesis for a patient after an accident at work. The finger prosthesis was retained by a vacuum effect on the stump. The silicone material Silastic-MDX 44210 was used to provide function and aesthetics. The finger prosthesis offered psychological, functional and rehabilitative advantages for the patient. Restoring the natural appearance with the prosthesis eliminated the trauma generated by the dysfunction and represented an efficient psychological therapy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objective of this study was to estimate the spatial distribution of work accident risk in the informal work market in the urban zone of an industrialized city in southeast Brazil and to examine concomitant effects of age, gender, and type of occupation after controlling for spatial risk variation. The basic methodology adopted was that of a population-based case-control study with particular interest focused on the spatial location of work. Cases were all casual workers in the city suffering work accidents during a one-year period; controls were selected from the source population of casual laborers by systematic random sampling of urban homes. The spatial distribution of work accidents was estimated via a semiparametric generalized additive model with a nonparametric bidimensional spline of the geographical coordinates of cases and controls as the nonlinear spatial component, and including age, gender, and occupation as linear predictive variables in the parametric component. We analyzed 1,918 cases and 2,245 controls between 1/11/2003 and 31/10/2004 in Piracicaba, Brazil. Areas of significantly high and low accident risk were identified in relation to mean risk in the study region (p < 0.01). Work accident risk for informal workers varied significantly in the study area. Significant age, gender, and occupational group effects on accident risk were identified after correcting for this spatial variation. A good understanding of high-risk groups and high-risk regions underpins the formulation of hypotheses concerning accident causality and the development of effective public accident prevention policies.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A 15-month-old DSH cat was presented with facial deformity secondary to multiple oral and maxillofacial fractures after being struck by an automobile. Multiple wires and dental acrylics were used for fracture repair.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A set of NIH Image macro programs was developed to make qualitative and quantitative analyses from digital stereo pictures produced by scanning electron microscopes. These tools were designed for image alignment, anaglyph representation, animation, reconstruction of true elevation surfaces, reconstruction of elevation profiles, true-scale elevation mapping and, for the quantitative approach, surface area and roughness calculations. Limitations on time processing, scanning techniques and programming concepts are also discussed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The stretch zone width (SZW) data for 15-5PH steel CTOD specimens fractured at -150 degrees C to + 23 degrees C temperature were measured based on focused images and 3D maps obtained by extended depth-of-field reconstruction from light microscopy (LM) image stacks. This LM-based method, with a larger lateral resolution, seems to be as effective for quantitative analysis of SZW as scanning electron microscopy (SEM) or confocal scanning laser microscopy (CSLM), permitting to clearly identify stretch zone boundaries. Despite the worst sharpness of focused images, a robust linear correlation was established to fracture toughness (KC) and SZW data for the 15-5PH steel tested specimens, measured at their center region. The method is an alternative to evaluate the boundaries of stretched zones, at a lower cost of implementation and training, since topographic data from elevation maps can be associated with reconstructed image, which summarizes the original contrast and brightness information. Finally, the extended depth-of-field method is presented here as a valuable tool for failure analysis, as a cheaper alternative to investigate rough surfaces or fracture, compared to scanning electron or confocal light microscopes. Microsc. Res. Tech. 75:11551158, 2012. (C) 2012 Wiley Periodicals, Inc.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: To physiologically reconstruct the biliary tract, Crema et al suggested the application of the Monti principle to the biliary tract, already used in humans for the urinary tract. With this technique, a jejunal segment is transversely retubularized. This study aimed to evaluate the efficacy of jejunal tube interposition between the common bile duct and duodenum in dogs.METHODS: Thirteen dogs underwent a laparoscopic common bile duct ligature, followed by a biliodigestive connection by jejunal tube interposition after one week. The levels of glutamic-pyruvic and glutamic-oxalacetic transaminases, total bilirubins, alkaline phosphatase and gamma-glutamyltransferase were assessed before surgery and thereafter weekly until euthanasia, which was performed 6 weeks after biliodigestive connection.RESULTS: Data on 9 dogs were analyzed statistically. The dogs presented with obstructive jaundice after common bile duct ligature, as confirmed by biochemical examination. They showed a statistically significant reduction in cholestasis after biliodigestive connection by jejunal tube interposition and were healthy until the end of the experiment.CONCLUSION: A statistically significant reduction was seen in total bilirubin and canalicular enzymes (alkaline phosphatase and gamma-glutamyltransferase) in the 9 dogs 6 weeks after biliodigestive conviction by jejunal tube interposition.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conus regius is a venomous mollusc in the Conidae family, which includes species responsible for severe or even fatal accidents affecting human beings. This is the first report on a clinical case involving this species. It consisted a puncture in the right hand of a diver who presented paresthesia and movement difficulty in the whole limb. The manifestations disappeared after around twelve hours, without sequelae.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

AIM: To evaluate the host response of the gel and porous polyethylene implants in anophthalmic cavities using the B scan ultrasound.METHODS: Thirty-six white rabbits underwent unilateral enucleation with placement of gel or porous polyethylene spheres implants. The animals were submitted to clinical examination weekly and to ultrasound evaluation on 30, 60 and 90 days after surgery.RESULTS: All rabbits with gel polyethylene spheres, except one, showed implant extrusion probably because the gel spheres have hydrated and increased in volume. The B ultrasound of the gel polyethylene implant did not show vessels inside during the following period. Five animals (27.8%) with porous polyethylene spheres presented implant extrusion after 30 days of surgery. According to B ultrasound, the porous polyethylene implant showed irregular and heterogeneous architecture and reflective peaks similar to vascularized tissues.CONCLUSION: More studies are required to determine the ideal volume of gel polyethylene implant necessary to correct the diminished orbital content in the anophthalmic cavity. The B ultrasound effectiveness showed in this study for anophthalmic socket implants evaluation provides useful information for further in vivo studies and might substitute expensive methods of implants vascularization evaluation,