20 resultados para ARM, Intensity, per unit volume

em Repositório Institucional UNESP - Universidade Estadual Paulista "Julio de Mesquita Filho"


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The population biology of Uca thayeri was studied in a subtropical mangrove in Ubatuba, State of São Paulo, Brazil. Two sampling techniques were used: transect sampling and catch-per-unit-effort. Size frequency distribution, sex-ratio, and reproductive period were analysed. For juvenile crabs (CW < 4.6 mm), the transect procedure was most efficient, while ovigerous females were most collected during the capture effort. Males were most numerous in the transect technique, while in the catch-per-unit-effort there was no difference between sexes. The species showed a different size frequency distribution for each sampling procedure. The reproduction of U. thayeri is seasonal, being more pronounced in the warmer months of the year. However, juveniles occurred all over the year, although more numerous in the colder months. The success of the species in reproductive activity and the constant colonization of the area can be attributed to the availability of food resources and differential occupation of the habitat by ovigerous females.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this work a detailed modeling of three-phase distribution transformers aimed at complementing well-known approaches is presented. Thus, incidence of angular displacement and tapping is taken into account in the proposed models, considering both actual values and per unit. The analysis is based on minimal data requirement: solely short-circuit admittance is needed since three-phase transformers are treated as non-magnetically-coupled single-phase transformers. In order to support the proposed methodology, results obtained through laboratory tests are presented.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This study reports the nature and extent of open-system interaction between groundwater and a weathered profile developed in the high grade thorium and REE ore body in Morro do Ferro, Pocos de Caldas plateau. The radioelement mobility in the shallow oxidizing environment was considered by using chemical data in conjunction with U-234/U-238, Ra-226/Th-230, Th-230/U-234, Th-228/Th-232, Ra-228/Th-232 and Th-230/Ra-228 activity ratios (AR's) for borehole spoil and groundwater samples.Recharging groundwater from the studied borehole has low salinity values, with total dissolved solids content of 14.7 mg/l and total ionic strength of 0.00018. The ratio of the weight of dissolved radioelement per unit volume of solution to the weight of radioelement in solid phase per unit weight of solid phase showed that the radioelement solubility in the studied waters varied according to the following order: radium> uranium >thorium.U-234/U-238 AR's less than 1 were measured in solid phase and can justify the enhancement of U-234 in solution. Ra-226/Th-230 AR's greater than 1 and Th-230/U-234 AR'S less than 1 were evaluated between 20 and 27 m in depth, where a 2.1-m thick magnetite dike was intersected. These ratios could be justified by deposition of U and Ra associated with Fe-Mn oxides and kaolinite, where mineral saturation indices evaluated from the available data confirm this possibility. Covariations among disequilibria involving Th-228/(228) Ra and Ra-228/Th-232 AR's showed the preferential removal of Ra-228 relative to Tn isotopes, Th-228 and Th-232. The recent deposition of radium within the timescale of at least the last 35 years also is suggested. (C) 1998 Elsevier B.V. Ltd. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Pós-graduação em Agronomia (Ciência do Solo) - FCAV

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The sol-gel process is a method for obtaining vitreous or vitro-ceramic materials which, are prepared a sol and by drying the liquid phase. This technique has been used extensively for the preparation of glassy gels, films, fibers and particles from the hydrolysis and polycondensation reactions of metal alkoxides. The usual methods for drying are: evaporation drying (xerogels), freeze drying (criogéis) and via supercritical CO2 extraction (aerogels). In the present work, we studied the preparation of silica gels by the sol-gel process from the hydrolysis of alkoxides tetraethylorthosilicate (TEOS) and 3-glycidoxypropyltrimethoxysilane (GPTS). The hydrolysis was promoted from GPTS and TEOS in proportion (4: 1) under acidic conditions. The hydrolysis reaction was promoted inside a Becker at room temperature. After hydrolyses the prepared sol had pH 2, and kept under mechanical agitation for a period of 1 hour. In order to accelerate the polycondensation reaction, the pH was corrected to a value near 5 by slowly adding NH4OH. Then the sols were leaked in sealed polycarbonate containers and maintained for 20 days at 40°C for gelation. Silica aerogels were prepared via supercritical CO2 extraction of the wet gel at temperature and pressure higher than 31°C and 74 atm, in an autoclave specially developed for the process. The structural characteristics were studied in the dry gel (aerogel). Aerogels were then characterized by nitrogen adsorption and small angle light scattering. The nitrogen adsorption data were analyzed for the determination of the BET specific surface (SBET), the total pore volume Vp, the pore mean size (lP=4Vp/SBET), the particle mean size (lS) and the pore size distribution (PSD). And the data from small angle light scattering were analyzed to determine the correlation function (γ'), the area per unit volume (S/V), average pore size (l ) and the average particle size...

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

O trabalho teve como objetivo estudar o desempenho de pontas de pulverização na deposição da calda inseticida para o controle de ninfas de cigarrinhas das pastagens em Brachiaria brizantha cv. MG-4. Doze tratamentos foram estudados em esquema fatorial 6x2, constituídos pelo contraste de seis pontas de pulverização e pressões de 196 e 392 kPa: TF-VP2 (336 L ha-1 e 467 L ha-1); AI11002-VS (184 L ha-1 e 200 L ha-1); XR11002-VS (200 L ha-1 e 280 L ha-1); TT11002-VP (200 L ha-1 e 280 L ha-1); TJ60-11002VS (208 L ha-1 e 280 L ha-1) e TX-VK4 (72 L ha-1 e 97 L ha-1). Para monitorar a deposição das caldas de pulverização, utilizaram-se os traçadores Azul Brilhante FD&C-1 (0,3% p/v) e Amarelo de Tartrasina FD&C-5 (0,6% p/v). Alvos artificiais, constituídos de lâminas de vidro, foram posicionados na base das plantas, próximos à superfície do solo, e os depósitos por unidade de área das soluções pulverizadas foram quantificados por espectrofotometria. As pontas TF-VP2, XR11002-VS e AI11002-VS, nas pressões de 196 e 392 kPa, proporcionam as maiores deposições da calda de pulverização na região das espumas das cigarrinhas das pastagens, apesar de apresentarem menor uniformidade na distribuição dos depósitos em relação a TX-VK4, XR110.02-VS e TJ110.02-VS. O aumento da pressão de 196 para 392 kPa promoveu aumento na deposição da calda de pulverização sobre a Brachiaria brizantha e na região onde se encontram as espumas das cigarrinhas para todos os tipos de pontas estudadas.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The effect of application with different nozzle types and volume rates on spray deposition in the V3 stage of two soybean cultivars was evaluated. The experiments were conducted in the Facultad de Ciencias Agronomicas of the UNESP-Botucatu/SP. The nozzles evaluated were an air induced flat fan nozzle (Al 11015 at 150 L ha(-1), Al 11002 at 200 and 250 L ha(-1)), a twin flat fan nozzle (TJ 60 11002 at 150, 200 and 250 L ha(-1)), and a cone nozzle (TX 6 at 150 L ha(-1), TX 8 at 150 L ha(-1) and TX 10 at 250 L ha(-1)). To evaluate spray deposition on the plants, a tracer (Brilliant Blue FD&C-1) was added. The experimental design was random blocks with four replications. Deposition on plants was determined by absorbancy reading in 630 nm wavelength. The data were adjusted to a calibration curve and transformed into deposited spray volume in mL. The relationship deposition per unit of dry matter was adjusted to a regression curve (Gompertz model). In cultivar CD 208, the highest deposit was for the larger volumes and for the treatment TX 8 200 L ha(-1). The most uniform treatments were all the nozzles with the volume 150 L ha(-1) and the TJ60 nozzle for 200 1, ha(-1). In cultivar CD 216, the greatest spray depositions were achieved with the treatments Al at 200 and 250 L ha(-1) and TJ 60 at 250 L ha(-1), and the most uniform treatments were the TX 6 and TJ60 nozzles for the volume150 L ha(-1).

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)