28 resultados para 99m

em Repositório Institucional UNESP - Universidade Estadual Paulista "Julio de Mesquita Filho"


Relevância:

20.00% 20.00%

Publicador:

Resumo:

To evaluate the tumor response to neoadjuvant chemotherapy, Tc-99m-sestamibi breast scintigraphy was proposed as a quantitative method Fifty-five patients with ductal carcinoma were studied They underwent breast scintigraphy before and after neoadjuvant chemotherapy, along with clinical assessment and surgical specimen analysis The regions of interest on the lesion and contralateral breast were identified, and the pixel counts were used to evaluate lesion uptake in relation to background radiation The ratio of these counts before to after neoadjuvant chemotherapy was assessed The decrease in uptake rate due to chemotherapy characterized the scintigraphy tumor response The Kruskal-Wallis test was used to compare the mean scintigraphic tumor response and histological type Dunn's multiple comparison test was used to detect differences between histological types The Mann-Whitney test was used to compare means between quantitative and qualitative variables scintigraphic tumor response vs clinical response and uptake before chemotherapy vs scintigraphic tumor response The Spearman's test was used to correlate the quantitative variables of clinical reduction in tumor size and scintigraphic tumor response All of the variables compared presented significant differences The change in Tc-99m-sestamibi uptake noted on breast scintigraphy, before to after neoadjuvant chemotherapy, may be used as an effective method for evaluating the response to neoadjuvant chemotherapy, since this quantification reflects the biological behavior of the tumor towards the chemotherapy regimen Furthermore, additional analysis on the uptake rate before chemotherapy may accurately predict treatment response

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Scintimammography using Tc-99m-sestamibi is a noninvasive and painless diagnostic imaging method that is used to detect breast cancer when mammography is inconclusive Because of the advantages of labeling v '7,ith Tc-99m-sestamibi and its high efficiency in detecting carcinomas, it is the most widespread agent for this purpose Its accumulation in the tumor has multifactorial causes and does not depend on the presence of architectural distortion or local or diffuse density variation in the breast The objective of tfiis study was to evaluate the accuracy of scintimammography 1 for detecting breast cancer One hundred and fifty-seven patients presenting 158 palpable and non-palpable breast nodules were evaluated Three patients were male and 154 were female, aged between 14 and 81 years All patients underwent scintimammography, and the nodule was subjected i to cytological or histological study, i e, the gold standard for diagnosing cancer One hundred and eleven malignant and 47 benign nodules were detected, with predominance of ductal carcinomas (n=94) and fibroadenoma/fibrocysiic condition (n=11/n=11), respectively The mean size was 3 11 cm (7-10 cm) among the malignant nodules and 2 07 cm among the benign nodules (0 5-10 cm) The sensitivity, specificity, positive predictive value, negative predictive value and accuracy were 89, 89, 95, 78 and 89%, respectively Analysis on the histological types showed that the technique was more effective on tumors that were more aggressive, such as ductal carcinoma In this study, Tc-99m-sestamibi scintim immography was shown to be an important tool for diagnosing breast cancer when mammography was inconclusive

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: To evaluate changes in mammographic density and Tc-99m-sestamibi scintimammographic uptake in postmenopausal women on hormone replacement therapy (HRT).Methods: Seventy-five postmenopausal women were prospectively studied and allocated into three groups: 50 women were randomized to either Group 1 (G1, n = 25), which received 2 mg of 17 beta-oestradiol continuously combined with 1 mg of norethisterone acetate (E-2/NETA, Kliogest (R), Medley) or Group 2 (G2), which received 2.5 mg/day of tibolone (Livial (R), Organon). The remaining 25 women, who were asymptomatic and had no desire to undergo HRT, constituted the control group (G3). Each patient was submitted to both mammography and scintimammography at baseline and after six months. Mammographic density was evaluated by using the BI-RADS classification system. The classification system of Barros et al. was used in the interpretation of scintimammography. For statistical analysis, the Chi-square test, ANOVA and Pearson's correlation were used.Results: At six months, increased mammographic density was observed in 48% of G1, 12% of G2 and 16% of G3 patients (p < 0.001). The increase in sestamibi uptake was 56% in G1, 28% in G2 and 24% in G3 (p < 0.001). Increases in both density and uptake were significantly higher in the group on E-2/NETA than among tibolone users and the controls.Conclusion: In postmenopausal women, HRT with E-2/NETA was associated with increased mammographic density and increased Tc-99m-sestamibi scintimammographic uptakes, suggesting greater mithochondrial activity in the cells of the mammary duct. This was not observed in users of 2.5 mg of tibolone, demonstrating that the effects on the breast were reduced. The same was observed in the control group. (c) 2005 Elsevier B.V.. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives. The aim of this study was to investigate the feasibility of sentinel lymph node (SLN) identification using radioisotopic lymphatic mapping with technetium-99 m-labeled phytate in patients undergoing radical hysterectomy with pelvic lymphadenectomy for treatment of early cervical cancer.Methods. Between July 2001 and February 2003, 56 patients with cervical cancer 1160 stage I (it 53) or stage 11 (it 3) underwent sentinel lymph node detection with preoperative lymphoscintigraphy (Te-99m-labeled phytate injected into the uterine cervix, at 3, 6, 9, and 12 o'clock, at a dose of 55-74 MBq in a volume of 0.8 ml) and intratoperative lymphatic mapping with a handheld gamma probe, Radical hysterectomy was aborted in three cases because parametrial invasion was found intraoperatively and we performed only sentinel node resection. The remaining 53 patients underwent radical hysterectomy with complete pelvic lymphadenectomy, Sentinel nodes were detected using a handheld gamma-probe and removed for pathological assessment during the abdominal radical hysterectomy and pelvic lymphadenectomy.Results. One or more sentinel nodes were detected in 52 out of 56 eligible patients (92.8%). A total of 120 SLNs were detected by lymphoscintigraphy (mean 2.27 nodes per patient) and intraoperatively by gamma probe, Forty-four percent of SLNs were found in the external iliac area, 39% in the obturator region, 8.3% in interiliae region, and 6.7),) in the common iliac area. Unilateral sentinel nodes were found in thirty-one patients (59%). The remaining 21 patients (4100 had bilateral sentinel nodes, Microscopic nodal metastases were confirmed in 17 (32%) cases. In 10 of these patients, only SLNs had metastases. The 98 sentinel node.,, that were negative on hematoxylin and eosin were submitted to cytokeratin immunohistochemical analysis. Five (5.1%) micrometastases were identified with this technique. The sensitivity of the sentinel node was 82.3% (CI 95% - 56.6-96.2) and the negative predictive value was 92.1% (CI 95% 78.6 98.3) the accuracy of sentinel node in predicting the lymph node status was 94.2%,Conclusion. Preoperative lymphoscintigraphy and intraoperative lymphatic mapping with Tc-99-labeled phytate are effective in identifying sentinel nodes in patients undergoing radical hysterectomy and to select women in whom lymph node dissection call be avoided. (c) 2005 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Abnormal intragastric distribution of food (IDF) and a phasic contractility in the proximal stomach have been related to dyspeptic symptoms. Thus, the behaviour of the stomach and the proximal region, in particular, continues to attract attention and demand for reliable and comfortable techniques. The aims of this study were to employ AC Biosus-ceptometry (ACB) and scintigraphy to evaluate IDF and gastric motor activity in humans. Fifteen healthy volunteers ingested 60 mL of yogurt containing 2 mCi of Tc-99m and 4 g of ferrite. Each volunteer had gastric motility and IDF evaluated twice on separate days; on one occasion by ACB and another by scintigraphy. Digital signal processing was performed in MatLab (Mathworks Inc., Natick, MA, USA). Results were expressed as mean +/- SD. Similar results of distal accumulation time (P < 0.001) were obtained for scintigraphy (6.93 +/- 3.25 min) and for ACB (7.04 +/- 3.65 min). Fast Fourier Transform revealed two dominant frequencies (P > 0.9). Besides the well-know frequency of 3 cpm, our results showed identical frequencies in proximal stomach recordings (P < 0.001) for scintigraphic (1.01 +/- 0.01 cpm) and ACB (0.98 +/- 0.06 cpm). In summary, our data showed that scintigraphy and ACB are promising techniques to evaluate several aspects of gastric motility. Moreover, ACB is non-invasive, radiation-free and deserves the same importance as conventional methods for this kind of analysis.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of this study was to confirm the effectiveness of early physiotherapeutic stimulation for lymphatic flaw progression in patients with breast cancer undergoing axillary dissection This was a randomized experimental study oil 22 patients who underwent lymphoscintigraphy in their arms on two different occasions, firstly without stimulation and secondly after randomization into two groups without physiotherapeutic stimulation (WOPS, n=10) and with physiotherapeutic stimulation (WPS, n=12) The lymphoscintigraphy scan was performed with (99m)Tc-phytate administered into the second interdigital space of the hand, ipsilaterally to the dissected axilla, in three phases dynamic, static, and delayed whole body imaging Physiotherapeutic stimulation was earned out using Foldi's technique In both groups, images from the two examinations of each patient were compared Flow progression was considered positive when, on the second damnation, the radiopharmaceutical reached areas more distant from the injection site Statistical analysis was used to evaluate frequencies, percentages and central trend measurements, and non-parametric tests were conducted Descriptive analysis showed that the WPS and WOPS groups were similar M terms of mean age, weight, height, body mass index and number of lymph nodes removed There were statistically significant associations between physiotherapeutic stimulation and radiopharmaceutical progression at all three phases of the study (p < 0 0001) Early physiotherapeutic stimulation in beast cancer patients undergoing radical axillary dissection is effective, and can therefore be indicated as a preventive measure against lymphedema

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The objective of this paper was to evaluate the hepatobiliary function of patients with pulmonary tuberculosis under triple treatment, using the technetium-99m-DISIDA (99mTc-DISIDA) hepatobiliary scintigraphy. Ten men and three women with pulmonary tuberculosis were subjected to hepatobiliary scintigraphy at the beginning of triple treatment (M1) and two months after it (M2). Patients were from the urban area, of low socioeconomic level, malnourished, and chronic alcohol and/or tobacco users. Ten normal individuals were evaluated as controls. Radiotracer images were acquired on a computerized gamma camera (Orbiter-Siemens) and T1/2 uptake and excretion values were calculated. Nutritional status and serum hepatic enzyme levels for each patient were evaluated at M1 and M2. None presented clinical or laboratory antecedent of hepatobiliary disease. At M1, there were no hepatic serum or kinetic alterations of the 99mTc-DISIDA. At M2, patients presented better nutritional conditions than at M1; there was increased serum aspartate aminotransferase (AST) and reduced excretion time for 99mTc-DISIDA, which was interpreted as a more adaptive than toxic phenomenon, yet not all alterations were significant and none manifested clinically. Apparently, triple treatment acted on the liver inducing the P450 cytochrome enzymatic system, accelerating radiotracer excretion, which follows the same path as the bilirubins.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Mutilation of extremities was very frequent in patients affected by leprosy in the past; although it is now much less common, it is still seen, mainly in patients with long-term disease. In general, mutilation of the nose and ears is caused by the bacillus and mutilation of the hands and feet a consequence of chronic trauma. Leprosy must be chronically treated and any decision to interrupt therapy is based on laboratory tests and biopsy. Scintigraphy is a non-invasive procedure which could be of great value in to determining disease activity. We studied eight patients (five males and three females, aged 64-73 years) who presented with mutilation of the nose (2), ear (1), feet (3) or foot and hand (2), Conventional three-phase bone scintigraphy (750 MBq) and X-ray examinations of the affected areas were performed in all patients. Bone scintigraphy was abnormal in four patients (the presence of bacilli was confirmed by biopsy in two of them), and normal in the other four. In all patients except for the one with ear mutilation, radiography only showed the absence of bone. We conclude that bone scintigraphy is very useful to determine disease activity in cases of mutilation caused by leprosy. It seems to be superior to conventional radiography and may enable bone biopsies to be avoided.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Aim of the study was to evaluate the influence of an extra corporal perfusion (cardiopulmonary bypass operation - cpb) on activation and biodistribution of Tc-99m labelled granulocytes in pigs with and without inhibition of the granulocytes by a leukocyte inhibition module (LIM). The cpb is often related to an activation of granulocytes resulting in an inflammatory answer. The biological mechanisms are unsolved yet. First trials of our group showed that LIM may inhibit the activation of neutrophils and therefore antagonize a cpb-caused impairment of cardiac function. This study is the continuation of these experiments with a higher number of animals and the focus on scintigraphic imaging. Animals, material, methods: 39 German landrace pigs were subdivided into three groups: group A (control) median sternotomy without cpb, group B with cpb, group C with LIM in addition to cpb. After labelling with Tc-99m-HMPAO autologues granulocytes were reinjected. Subsequently to cpb, the animals underwent scintigraphic imaging. Quantification was performed with ROI evaluation and with tissue samples (section analysis) examined in a well counter. Results:A high uptake of Tc-99m-HMPAO was found in the liver. The count rates in brain, heart, lung, spleen and kidneys were far below. The amount of Tc-99m-activity in the organ related to the half life corrected administered activity [%] was for the tissue samples (group A/B/C): brain 0.01/0.02/0.03; lung 12.1/8.3/11.5; heart 0.35/0.54/0.42; kidney 1.24/0.87/1.02; spleen 4.0/4.0/4.5, liver 16.8/20.9/19.6. The count rates determined by ROI-evaluation of the scintigraphic images related to the total count rate in the image [%] were (group A/B/C): brain 1.1/0.9/1.0; lung 15.6/10.4/12.2; heart 4.0/3.5/3.4; kidney 4.0/2.9/3.2; spleen 7.6/7.7/9.5, liver 23.1/36.7/31.4. A significant difference in the tracer uptake between the groups could neither be detected by scintigraphic imaging nor evaluation of tissue samples. Conclusion: Scintigraphic imaging as well as section analysis showed a comparable biodistribution of the tracer. Therefore, the initial results of our group were not confirmed with a considerably higher number of animals. Neither cpb nor the use of the LIM influenced distribution of Tc-99m-labelled granulocytes in pigs significantly.