29 resultados para 671503 Appliances and electrical machinery and equipment
em Repositório Institucional UNESP - Universidade Estadual Paulista "Julio de Mesquita Filho"
Resumo:
A cárie secundária representa problema de saúde pública e socioeconômico no mundo. A restauração de dentes acometidos por cárie pode criar condições favoráveis à proliferação microbiana na superfície do material restaurador ou na interface dente/restauração, criando ambiente propício para o estabelecimento de cárie secundária. O objetivo deste estudo foi avaliar a capacidade de retenção de placa bacteriana em cimentos de ionômero de vidro convencionais (Chelon-Fil e Vidrion R) e modificados por resina (Vitremer e Fuji II LC) e de resina composta híbrida (Z100), utilizada como controle. Nos testes de retenção de microrganismos, in situ, 12 voluntários utilizaram, por 7 dias, placa de Hawley contendo corpos-de-prova de todos os materiais. A seguir, os corpos-de-prova foram transferidos para tubos contendo 2,0 ml de Ringer-PRAS e os microrganismos presentes em sua superfície foram cultivados em placa com ágar-sangue e ágar Mitis Salivarius Bacitracina, os quais foram incubados, a 37ºC, em anaerobiose (90% N2, 10% CO2), por 10 e 2 dias, respectivamente. Os ionômeros modificados por resina retiveram quantidade de bactérias similar àquela mostrada pela resina testada. Os ionômeros modificados por resina também apresentaram menor número de estreptococos do grupo mutans do que a resina e os cimentos ionoméricos convencionais. Os ionômeros de vidro convencionais apresentaram menor número de estreptococos do grupo mutans que a resina, sendo que essa diferença não foi estatisticamente significativa.
Resumo:
The aim of this study was to compare the in situ and in vitro performances of a laser fluorescence (LF) device (DIAGNOdent 2095) with visual inspection for the detection of occlusal caries in permanent teeth. Sixty-four sites were selected, and visual inspection and LF assessments were carried out, in vitro, three times by two independent examiners, with a 1-week interval between evaluations. Afterwards, the occlusal surfaces were mounted on the palatal portion of removable acrylic orthodontic appliances and placed in six volunteers. Assessments were repeated and validated by histological analysis of the tooth sections under a stereomicroscope. For both examiners, the highest intra-examiner values were observed for the visual inspection when in vitro and in situ evaluations were compared. The inter-examiner reproducibility varied from 0.61 to 0.64, except for the in vitro assessment using LF, which presented a lower value (0.43). The methods showed high specificity at the D(1) threshold (considering enamel and dentin caries as disease). In vitro evaluations showed the highest values of sensitivity for both methods when compared to the in situ evaluations at D(1) and D(2) (considering only dentinal caries as the disease) thresholds. For both methods, the results of sensitivity (at D(1) and D(2)) and accuracy (at D(1)) showed significant differences between in vitro and in situ conditions. However, the sensitivity (at D(1) and D(2)), specificity and accuracy (both at D(1)) of the methods were not significantly different when the same condition was considered. It can be concluded that visual inspection and LF showed better performance in vitro than in situ.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Secondary caries is the main cause of direct restoration replacement. The purpose of this study was to analyze enamel adjacent to different restorative materials after in situ cariogenic challenge using polarized-light microscopy (PLM), scanning electron microscopy (SEM) and energy-dispersive X-ray analysis (EDS). Twelve volunteers, with a low level of dental plaque, a low level of mutans streptococci, and normal salivary flow, wore removable palatal acrylic appliances containing enamel specimens restored with Z250 composite, Freedom composite, Fuji IX glass-ionomer cement, or Vitremer resin-modified glass-ionomer for 14 days. Volunteers dripped one drop of 20% sucrose solution (n = 10) or distilled water (control group) onto each specimen 8 times per day. Specimens were removed from the appliances and submitted to PLM for examination of the lesion area (in mm(2)), followed by dehydration, gold-sputtering, and submission to SEM and EDS. The calcium (Ca) and phosphorus (P) contents were evaluated in weight per cent (%wt). Differences were found between Z250 and Vitremer, and between Z250 and FujiIX, when analyzed using PLM. Energy-dispersive X-ray analysis results showed differences between the studied materials regarding Ca %wt. In conclusion, enamel adjacent to glass-ionomer cement presented a higher Ca %wt, but this material did not completely prevent enamel secondary caries under in situ cariogenic challenge.
Resumo:
This paper presents a tool box developed to read files describing a SIMULINK® model and translates it into a structural VHDL-AMS description. In translation process, all files and directory structures to simulate the translated model on SystemVision™ environment is generate. The tool box named MS2SV was tested by three models of commercially available digital-to-analogue converters. All models use the R2R ladder network to conversion, but the functionality of these three components is different. The methodology of conversion of the model is presents together with sort theory about R-2R ladder network. In the evaluation of the translated models, we used a sine waveform input signal and the waveform generated by D/A conversion process was compared by FFT analysis. The results show the viability of this type of approach. This work considers some of challenges set by the electronic industry for the further development of simulation methodologies and tools in the field of mixed-signal technology. © 2007 IEEE.
Resumo:
Using robots for teaching is one approach that has gathered good results on Middle-School, High-School and Universities. Robotics gives chance to experiment concepts of a broad range of disciplines, principally those from Engineering courses and Computer Science. However, there are not many kits that enables the use of robotics in classroom. This article describes the methodologies to implement tools which serves as test beds for the use of robotics to teach Computer Science and Engineering. Therefore, it proposes the development of a flexible, low cost hardware to integrate sensors and control actuators commonly found on mobile robots, the development of a mobile robot device whose sensors and actuators allows the experimentation of different concepts, and an environment for the implementation of control algorithms through a computer network. This paper describes each one of these tools and discusses the implementation issues and future works. © 2010 IEEE.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
The present work aims to study the microstructure and mechanical properties of titanium alloys, widely used in the manufacture of orthopedic implants in order to compare a new manufacturing technology of implants, rapid prototyping in metals with conventional manufacturing processes. Rapid prototyping is being used in many areas of human knowledge to assist in the study and often in the manufacture of components for their own use. Nowadays with the advancement of software and equipment such as computed tomography and magnetic resonance imaging, we can reproduce any part of the human body in three-dimensional images with great perfection and it is used in the reproduction of implants, scaffolds, material aid and preparation in surgery. This work aims to do: A comparison between the microstructure of the alloy in the two manufacturing processes (prototyping and conventional), showing the grain size, the nature, form, quantity, and distribution of various ingredients or certain inclusions and study of mechanical properties of titanium in both cases.
Resumo:
Aim: The purpose of this study was to assess chlorhexidine effects on plaque index and salivary levels of mutans streptococci (MS) when used as the immersion solution for removable orthodontic appliances and added to their acrylic resin composition. Methods: Forty-five patients (6 to 12 years old) were randomly assigned into three groups with 15 patients each. Group I (control)—without orthodontic appliances disinfection; Group II—removable orthodontic appliances which had been immersed in 0.12% chlorhexidine digluconate overnight (8 hours), and Group III—orthodontic appliances in which 0.12% chlorhexidine digluconate solution had been incorporated into their resin composition. Saliva was collected for quantification of MS and evaluation of plaque index was performed before and after installation of orthodontic appliance at 0, 2, 4, 6, 8, and 10 weeks. Data were analyzed by using analysis of variance. Results: Number of MS colonies in saliva and plaque index showed no statistically differences among groups at the different periods (p > 0.05). Conclusions: It could be concluded that chlorhexidine incorporation into the acrylic resin of removable orthodontic appliances at 0.12% concentration and immersion of the appliance into 0.12% chlorhexidine solution were not effective in reducing plaque index and the number of MS in saliva.
Resumo:
We present here the results of a study of 21 work-related accidents that occurred in a Brazilian manufacturing company. The aim was to assess the safety level of the company to improve its work accident prevention policy. In the last 6 months of 1992 and 1993, all accidents resulting in 15 days' absence from work, reported for social security purposes, were analyzed using the INRS causal tree method (ADC) and a questionnaire completed on site. Potential risk factors for accidents were identified based on the specific factors highlighted by the ADC. More universal trees were also compiled for the safety assessment. Three hundred and thirty specific accident factors were recorded (man of 15.71 per accident). This is consistent with there being multiple causes of accidents rather than the assertion of Brazilian business safety departments that accidents are due to 'dangerous' or 'unsafe' behavior. Introducing the idea of culpability into accidents prevents the implementation of an appropriate information feedback process, essential for effective prevention. However, the large number of accidents related to 'material' (78%) and 'environment' (70%) indicates that working conditions are poor. This shows that the technical risks, mostly due to unsafe machinery and equipment are not being dealt with. Seventy-five potential accident factors were identified. Of these, 35% were 'organizational', a high proportion for the company studied. Improvisation occurs at all levels, particularly at the organizational level. This is, thus a major determinant for entire series of, if not most, accident situations. The poor condition of equipment also plays a major role in accidents. The effects of poor equipment on safety exacerbate the organizational shortcomings. The company's safety intervention policy should improve the management of human resources (rules designating particular workers for particular workstations; instructions for the safe operation of machines and equipment; training of operators, etc.) and introduce programs to detect risks and to improve the safety of machines and equipment. We also recommend the establishment of a program to follow the results of any preventive measures adopted.
Resumo:
We present here the results of a study of 21 work-related accidents that occurred in a Brazilian manufacturing company. The aim was to assess the safety level of the company to improve its work accident prevention policy. In the last 6 months of 1992 and 1993, all accidents resulting in 15 days' absence from work, reported for social security purposes, were analyzed using the INRS causal tree method (ADC) and a questionnaire completed on site. Potential risk factors for accidents were identified based on the specific factors highlighted by the ADC. More universal trees were also compiled for the safety assessment. Three hundred and thirty specific accident factors were recorded (mean of 15.71 per accident). This is consistent with there being multiple causes of accidents rather than the assertion of Brazilian business safety departments that accidents are due to dangerous or unsafe behavior. Introducing the idea of culpability into accidents prevents the implementation of an appropriate information feedback process, essential for effective prevention. However, the large number of accidents related to material (78%) and environment (70%) indicates that working conditions are poor. This shows that the technical risks, mostly due to unsafe machinery and equipment are not being dealt with. Seventy-five potential accident factors were identified. Of these, 35% were organizational, a high proportion for the company studied. Improvisation occurs at all levels, particularly at the organizational level. This is thus a major determinant for entire series of, if not most, accident situations. The poor condition of equipment also plays a major role in accidents. The effects of poor equipment on safety exacerbate the organizational shortcomings. The company's safety intervention policy should improve the management of human resources (rules designating particular workers for particular workstations; instructions for the safe operation of machines and equipment; training of operators, etc.) and introduce programs to detect risks and to improve the safety of machines and equipment. We also recommend the establishment of a program to follow the results of any preventive measures adopted.
Resumo:
This paper proposal presents the development and the experimental analysis of a new single-phase hybrid rectifier structure with high power factor (PF) and low harmonic distortion of current (THDI), suitable for application in traction systems of electrical vehicles pulled by electrical motors (trolleybus), which are powered by urban distribution network. This front-end rectifier structure is capable of providing significant improvements in trolleybuses systems and in the urban distribution network costs, and efficiency. The proposed structure is composed by an ordinary single-phase diode rectifier with parallel connection of a switched converter. It is outlined that the switched converter is capable of composing the input line current waveform assuring high power factor (HPF) and low THDI, as well as ordinary front-end converter. However, the power rating of the switched converter is about 34% of the total output power, assuring robustness and reliability. Therefore, the proposed structure was named single-phase HPF hybrid rectifier. A prototype rated at 15kW was developed and analyzed in laboratory. It was found that the input line current harmonic spectrum is in accordance with the harmonic limits imposed by IEC61000-3-4. The principle of operation, the mathematical analysis, the PWM control strategy, and experimental results of a 15kW prototype are also presented in this paper. © 2009 IEEE.
Resumo:
This paper presents the development and experimental analysis of a special input stage converter for a Trolleybus type vehicle allowing its operation in AC (two wires, single-phase) or DC distribution networks. The architecture of proposed input stage converter is composed by five interleaved boost rectifiers operating in discontinuous conduction mode. Furthermore, due to the power lines characteristics, the proposed input power structure can act as AC to DC or as DC to DC converter providing a proper DC output voltage range required to the DC bus. When operation is AC to DC, the converter is capable to provide high power factor with reduced harmonic distortion for the input current, complying with the restrictions imposed by IEC 61000-3-4 standard. Finally, the main experimental results are presented in order to verify the feasibility of the proposed converter, demonstrating the benefits and the possibility for AC feeding system for trolleybus type vehicle. © 2010 IEEE.