73 resultados para ângulo articular
em Repositório Institucional UNESP - Universidade Estadual Paulista "Julio de Mesquita Filho"
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Pós-graduação em Bases Gerais da Cirurgia - FMB
Resumo:
Individuals with spastic cerebral palsy show muscle weakness, difficulties in the control of agonist and antagonist muscles, decreased range of motion and tonus and sensibility alterations, especially in knee joint. These problems can interfere on the performance of functional activities such gait. The aim of this study was to analyze the contribution of knee range of motion on gait of hemiplegic and diplegic children considering their asymmetries. Twelve children, 6 hemiplegics e 6 diplegics from 7 to 12 years of age (age average= 9,5 ± 1,93) took part. Spasticity was assessed by the Ashworth’s Modified Scale and the passive knee range of motion by an eletrogoniometer. The task was to walk on a walkway of 8m long, in their preferred speed, in 6 attempts, been 3 on right and 3 on left sagital planes. Eigth passive markers were bilaterally fixed for the kinematic record. Orthogonally to the walkway, two digital camcorders were assembled on the sagital plane. The fotogrametric procedures were performed by the Dvideow 6.3 software. The Matlab 7.0.1 software was used to filter and to calculate the dependent variables. The U test of Mann- Whitney found differences to the cerebral palsy type for knee extension/hiperextension (U = - 2.943; p= 0.003), knee relative angle at heel contact (U = - 5.992; p= 0.001) and knee range during stride (U = - 4.099; p= 0.001). The Wilcoxon’s test revealed differences according to the asymmetries for the hemiplegics only for the knee relative angle at heel contact (T= - 2.635; p<0.008). The contributions of passive knee range of motion, revealed by the Spearman correlations, for the more afected limb of the diplegics, showed that the knee extension/hiperextension interfere on the cadence, stride duration and step width; the knee relative angle at heel contact change the stride length and duration and cadence; and the...(Complete abstract click electronic access below)
Resumo:
Determinaram-se os índices de largura da fossa intercondilar (FI), após transecção do ligamento cruzado cranial em nove cães adultos submetidos à estabilização articular com retalho de fáscia lata. Os joelhos foram alocados em dois grupos, sendo o joelho direito (GI) submetido à incisuroplastia troclear (ITR) e posterior estabilização articular, e o joelho esquerdo submetido somente à substituição ligamentar (GC). Cada grupo foi dividido em três subgrupos correspondentes aos momentos de eutanásia aos 30, 90 e 180 dias de pós-operatório. Os índices de largura da FI foram determinados, macroscópica e radiograficamente, pela mensuração da abertura cranial da FI nos terços cranial, médio e caudal, e indexados em relação à largura epicondilar. Observou-se aumento significativo dos índices macroscópicos e radiográficos nas articulações do GI, sendo estes estatisticamente diferentes daqueles das articulações de GC. Não foi observada estenose intercondilar nos joelhos de GC após a estabilização articular. Conclui-se que a estabilização articular com retalho de fáscia lata preveniu a estenose da fossa intercondilar, e que a ITR promoveu o alargamento permanente dessa estrutura.
Resumo:
O presente trabalho teve por objetivo avaliar a quantidade de calda de pulverização depositada nas folhas de Brachiaria plantaginea, em aplicações de pós-emergência precoce, em que se variou o volume de calda de pulverização, a densidade de plantas m-2 e o ângulo de posicionamento da ponta de pulverização na barra de aplicação. Para isso, foram conduzidos três experimentos em condições de laboratório. Nestes estudos, o volume de calda de pulverização foi obtido por meio da variação da velocidade de deslocamento de um veículo composto por plataforma e quatro rolamentos tracionados por um motor elétrico. Foi utilizada a ponta de pulverização XR Teejet 8001 EVS, na pressão de 241,4 kPa. O delineamento experimental utilizado foi o inteiramente casualizado, com cinco repetições. No primeiro experimento, os volumes utilizados foram de 1147,57; 860,68; 573,78; 459,02; 344,27; 229,51; 114,75; e 57,37 L ha-1 de calda de pulverização, com densidade de 600 plantas m-2. No segundo experimento foram estudadas as densidades de 300, 600, 900 e 1.200 plantas m-2; neste caso, utilizou-se o volume de 229,51 L ha-1 de calda de pulverização. No terceiro experimento avaliou-se o posicionamento do ângulo da ponta de pulverização na barra de aplicação e utilizou-se a densidade de 600 plantas m-2. Estudaram-se os ângulos de -30º, -15º, 90º, +15º e +30º e os volumes de calda de pulverização de 198,76; 221,69; 229,51; 221,69; e 198,76 L ha-1, respectivamente. Foram adotados sinais negativos para o sentido de deslocamento do veículo e sinais positivos para o sentido contrário ao deslocamento. As avaliações do depósito de calda de pulverização, na planta e no solo, foram feitas utilizando-se condutividade elétrica. A porcentagem de depósito de calda de pulverização nas plantas de B. plantaginea foi incrementada com a redução do volume de calda pulverizada por hectare. O depósito de calda por planta foi maior nas densidades maiores de plantas. O ângulo de posicionamento da ponta de pulverização na barra de aplicação incrementou o depósito de calda nas plantas de B. plantaginea, quando comparado com o ângulo de 90º.
Resumo:
O trabalho objetivou avaliar o efeito de surfatantes em soluções aquosas sobre a tensão superficial dinâmica e ângulo de contato das gotas em diferentes superfícies: artificiais (lâmina de vidro e de óxido de alumínio) e naturais (superfícies adaxiais de folhas de Euphorbia heterophylla, Ipomoea grandifolia e Brachiaria plantaginea). Seis formulações de surfatantes (Antideriva®; Uno®; Pronto 3®; Li-700®; Supersil® e Silwet L-77®), respectivamente nas doses recomendadas do produto comercial (0,050; 0,025; 0,100; 0,250; 0,100 e 0,100 % v v-1) e o dobro delas, foram avaliadas em soluções aquosas. A tensão superficial dinâmica e o ângulo de contato formado sobre as superfícies naturais foram medidos por tensiômetro. Os ângulos de contato formados pelas gotas nas superfícies artificiais foram obtidos por análise de imagens capturadas por uma câmera digital. Os surfatantes influenciam nas propriedades físico-químicas de soluções aquosas. As soluções contendo os surfatantes Silwet L-77® e Supersil®; nas doses de 0,100 e 0,200% v v-1; proporcionaram maiores reduções na tensão superficial dinâmica e menores ângulos de contato das gotas sobre as superfícies artificiais e naturais. Os surfatantes organossiliconados em solução aquosa foram mais eficientes na redução da tensão superficial e proporcionaram maior molhamento de superfícies natural e artificial. em alvos naturais, essas propriedades obtidas com organossiliconados são dependentes das características de superfície das espécies vegetais.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Purpose: This study evaluated the affect of disc displacement and articular disc repositioning on stability after surgical counterclockwise rotation and advancement of the maxillomandibular complex.Patients and Methods: A total of 72 patients (59 females, 13 males), with an average age of 30 years (range, 15 to 60 years) were evaluated. The patients were divided into 3 groups. Group 1 (G1; n = 21), with healthy temporomandibular joints (TMJs), underwent double jaw surgery only. Group 2 (G2; n = 35), with articular disc dislocation, underwent articular disc repositioning using the Mitek anchor (Mitek Surgical Products, Westwood, MA) technique concomitantly with orthognathic surgery. Group 3 (G3; n = 16), with articular disc dislocation, underwent orthognathic surgery only. Average postsurgical follow-up was 31 months. Each patient's lateral cephalograms were traced, digitized twice, and averaged to estimate surgical changes and postsurgical stability.Results: After surgery, the occlusal plane angle was decreased significantly in all 3 groups: by -6.3 +/- -15.0 degrees in G1, by -9.6 +/- 4.8 degrees in G2, and by -7.1 +/- 4.8 degrees in G3. The maxillomandibular complex was advanced and rotated counterclockwise similarly in all 3 groups, with advancement at the menton of 12.4 +/- 5.5 mm in G1, 13.5 +/- 4.3 mm in G2, and 13.6 +/- 5.0 mm in G3; advancement at the B point of 9.5 +/- 4.9 mm in G1, 10.2 +/- 3.7 mm in G2, and 10.8 +/- 3.7 mm in G3; and advancement at the lower incisor edge of 7.1 +/- 4.6 mm in G1, 6.6 +/- 3.2 mm in G2, and 7.9 +/- 3.0 mm in G3. Postsurgery, the occlusal plane angle increased in G3 (2.6 +/- 3.8 degrees; 37% relapse rate) but remained stable in G1 and G2. Postsurgical mandibular changes in the horizontal direction demonstrated a significant relapse in G3 at the menton (-3.8 +/- 4.1 mm; 28%), the B point (-3.0 +/- 3.4 mm; 28%), and the lower incisor edge (-2.3 +/- 2.1 mm; 34%) but remained stable in G1 and G2.Conclusions: Maxillomandibular advancement with counterclockwise rotation of the occlusal plane is a stable procedure for patients with healthy TMJs and for patients undergoing simultaneous TMJ disc repositioning using the Mitek anchor technique. Those patients with preoperative TMJ articular disc displacement who underwent double-jaw surgery and no TMJ intervention experienced significant relapse. (C) 2008 American Association of Oral and Maxillofacial Surgeons.
Resumo:
Mineralization of the articular cartilage is a pathological condition associated with age and certain joint diseases in humans and other mammals. In this work, we describe a physiological process of articular cartilage mineralization in bullfrogs. Articular cartilage of the proximal and distal ends of the femur and of the proximal end of the tibia-fibula was studied in animals of different ages. Mineralization of the articular cartilage was detected in animals at 1 month post-transformation. This mineralization, which appeared before the hypertrophic cartilage showed any calcium deposition, began at a restricted site in the lateral expansion of the cartilage and then progressed to other areas of the epiphyseal cartilage. Mineralized structures were identified by von Kossa's staining and by in vivo incorporation of calcein green. Element analysis showed that calcium crystals consisted of poorly crystalline hydroxyapatite. Mineralized matrix was initially spherical structures that generally coalesced after a certain size to occupy larger areas of the cartilage. Alkaline phosphatase activity was detected at the plasma membrane of nearby chondrocytes and in extracellular matrix. Apoptosis was detected by the TUNEL (TDT-mediated dUTP-biotin nick end-labeling) reaction in some articular chondrocytes from mineralized areas. The area occupied by calcium crystals increased significantly in older animals, especially in areas under compression. Ultrastructural analyses showed clusters of needle-like crystals in the extracellular matrix around the chondrocytes and large blocks of mineralized matrix. In 4-year-old animals, some lamellar bone (containing bone marrow) occurred in the same area as articular cartilage mineralization. These results show that the articular cartilage of R. catesbeiana undergoes precocious and progressive mineralization that is apparently stimulated by compressive forces. We suggest that this mineralization is involved in the closure of bone extremities, since mineralization appears to precede the formation of a rudimentary secondary center of ossification in older animals.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Utilizou-se a osteotomia femoral em cúpula em um cão que apresentava aumento do ângulo de inclinação do colo do fêmur e subluxação da articulação coxofemoral. A linha de osteotomia situou-se cerca de 1 cm distal ao trocanter menor, no sentido látero-medial. Para a imobilização utilizou-se um fio de Steinmann passando pelo trocanter maior e por toda a extensão do fêmur. Um fio de aço foi colocado em orifícios ósseos produzidos nos segmentos proximal e distal do fêmur para a realização de sutura óssea. A técnica empregada culminou em: diminuição de 35° no ângulo de inclinação, rebaixamento da cabeça do fêmur, elevação do trocanter maior, congruência da articulação e encurtamento de 3cm do membro. A consolidação ocorreu cerca de 90 dias após a cirurgia.
Resumo:
A ruptura do ligamento cruzado cranial é uma das principais doenças ortopédicas que afetam os cães. Muitas técnicas cirúrgicas foram descritas no intuito de aliviar a dor, restaurar a estabilidade biomecânica do joelho e prevenir a progressão da osteoartrite. Fáscia lata, fio de poliéster trançado e fio de poliamida foram empregados na estabilização do joelho após excisão do ligamento cruzado cranial em cães, os quais foram submetidos à avaliação radiográfica e macroscópica da articulação. Neste estudo, foram utilizados 18 cães com massa corporal superior a 15Kg (peso médio - 19,67kg), separados em 3 grupos eqüitativos correspondentes a cada técnica, avaliados durante 30 e 60 dias. Ao exame radiográfico, independentemente de grupo, os cães apresentaram evidência de efusão articular moderada a severa, distensão da cápsula articular e, na maioria dos casos, ausência de sinais de doença articular degenerativa. Ao exame macroscópico da articulação do joelho observou-se espessamento da cápsula articular e tecidos moles periarticulares, erosão da cartilagem articular dos côndilos femorais em todos os grupos e afrouxamento dos fios nos cães submetidos às técnicas de estabilização extra-articular com fio de poliéster trançado e fio de poliamida.
Resumo:
Avaliou-se o centro instantâneo de movimento e vetor velocidade após a transecção do ligamento cruzado cranial (LCCr), seguida da substituição ligamentar por retalho de fáscia lata, associada ou não a incisuroplastia troclear (ITR) em nove cães adultos. O joelho direito (GI) foi submetido a ITR e posterior estabilização articular, e o joelho esquerdo submetido somente a substituição ligamentar (GC). Os animais foram avaliados nos períodos pré-operatório, pós-operatório imediato e aos 30, 90 e 180 de pós-operatório, correspondente ao momento de eutanásia de subgrupos de três animais. O centro instantâneo de movimento (CIM) e o vetor velocidade (Vv) resultante foram determinados por meio do deslocamento de pontos a partir da análise radiográfica dos joelhos. Todas as articulações apresentavam CIM e Vv normais antes da transecção do ligamento cruzado cranial. Após a estabilização articular, acompanhada ou não de ITR, observou-se o posicionamento normal do CIM e Vv resultante, em todos os períodos de avaliação, apesar da presença de movimento de gaveta em três animais de GC e dois de GI no pós-operatório imediato, em dois animais de cada grupo, aos 30 dias de avaliação, e em um animal em cada grupo nas avaliações subseqüentes. Conclui-se que a estabilização articular com retalho de fáscia lata, associada ou não a ITR, mantém a integridade biomecânica do joelho, quando considerados o CIM e o Vv.
Resumo:
Avaliaram-se as alterações clínicas e radiográficas em nove cães adultos, após a transecção do ligamento cruzado cranial (LCCr) seguida da substituição ligamentar por retalho de fáscia lata, associada ou não à incisuroplastia troclear (ITR). O joelho direito (GI) foi submetido à ITR e posterior estabilização articular, e o esquerdo somente à substituição ligamentar (GC). Os animais foram avaliados nos períodos pré-operatório, pós-operatório (po) imediato e aos 30, 90 e 180 dias de po, período coincidente com o momento de eutanásia de subgrupos de três cães. A instabilidade articular e o grau de claudicação diminuíram significativamente durante o período de avaliação, apesar da instabilidade persistir durante a flexão articular. Observou-se decréscimo significativo do perímetro muscular da coxa aos 30 e 90 dias p.o. em ambos os grupos. Não foram evidenciadas alterações nos graus de extensão e flexão articulares, na rotação interna da tíbia, na amplitude de movimento articular ou de doença articular degenerativa (DAD) durante o período de avaliação em ambos os grupos. Conclui-se que a ITR, associada à técnica de estabilização articular, não produz alterações em nenhuma das variáveis estudadas em cães, quando comparada à estabilização intra-articular, isoladamente.
Resumo:
Dentre as pesquisas empreendidas no campo da epidemiologia, um grupo específico aborda patologias de etiologia desconhecida ou não totalmente compreendidas. É dentro deste grupo que estão situadas as desordens temporomandibulares (DTM). Três estratégias observacionais básicas têm sido utilizadas para abordar o papel etiológico da má oclusão no desenvolvimento das DTM, dentro do repertório epidemiológico. São elas: estudos do tipo transversal, estudos de caso controle e estudos de coorte. Alguns experimentos clínicos são realizados com base na remoção do fator etiológico suspeito. Com base em uma revisão estruturada da literatura, a partir da metodologia empregada nos estudos selecionados, podemos concluir que a definição dos possíveis fatores etiológicos relacionados a subgrupos específicos de DTM é fundamental para que o papel das más oclusões no desenvolvimento destas desordens, embora pareça pequeno quando baseado nas evidências disponíveis, não seja subestimado. Pode ser útil a caracterização de uma oclusão normal como aquela associada como o menor risco para o desenvolvimento de problemas de DTM, mas é provavelmente inapropriada a aplicação destes parâmetros para reverter um problema intra-capsular já estabelecido. O conceito de uma oclusão de baixo fator de risco implicaria em um pequeno desvio entre RC e MIH, pequeno transpasse horizontal, transpasse vertical positivo e ausência de mordida cruzada posterior. Este conceito é compatível com o conceito de oclusão normal defendido por décadas, embora uma variação do normal ao invés de um critério absoluto deva ser permitida. Embora provavelmente seja prudente estabelecer metas morfológicas terapêuticas que busquem o que é observado em oclusões não tratadas julgadas normais ou ideais, o estabelecimento de uma oclusão que alcance todos os critérios gnatológicos, por meio de tratamento ortodôntico, talvez seja impossível e provavelmente desnecessário.