17 resultados para água de refrigeração
em Repositório Institucional UNESP - Universidade Estadual Paulista "Julio de Mesquita Filho"
Resumo:
In this work, it was studied the thermal and fluid dynamic behavior from theorical and experimental point of view of a blast furnace tuyere. The tuyere is responsible for the hot air insuflation into the blast furnace. The parameter used in the comparison was the difference between the cooling water inlet and outlet temperatures. There were used forced convection correlations inside circular sections with adequations for non circular sections. Based on operations dates of flux and thermal loads it was possible to model numerically the tuyere, and, since it was obtained the wall temperatures, estimate the conduction and convection resistances and the heat flux through the walls in contact with the water. The total heat fluxes from wall to water were applied to the energy conservation equation where could be estimated the theorical temperature variation. Compared to the real value, the theorical value presented a difference of 0,2 °C. Considering that the boundary conditions around the tuyere are transitories and that your channels have some rugosity irregularities we can consider the estimation method for cooling system coherent with the real operational parameters
Resumo:
The aim of this study was to compare temperature increases produced by a well-known equipment, the high-speed handpieces, with a relatively new instrument, the Er:YAG laser (350 mJ/10 Hz). Thirty-five bovine mandibular incisors, which were reduced to an enamel/dentin thickness of 2,5 mm, were used. Cavity preparation was done till a depth of 2, 5 mm. A thermocouple was placed to read the temperature inside of the pulp chamber. Analysis was performed in these groups: I - high-speed handpiece without water-cooling (n=10); II - high-speed handpiece with water-cooling (n=10); III - Er:YAG laser without water-cooling (n=5); IV- Er:YAG laser with water-cooling (n=10) Group III had only 5 teeth because it was impossible to properly make the cavity preparations by the laser equipment without water cooling. The temperature increases were recorded in a computer linked to the thermocouples and the data of the groups I, II and IV were submitted to Dunn's multiple comparison test (p<0,05). The medium temperature increases were: 11,64ºC for group I, 0,96ºC for group II, 40,86ºC for group III and 2,9°C for group IV. There were no statistical differences between groups lI and IV, and these were different from group I. The cavity preparations made by the high-speed and the laser equipment generated very similar heat increases under water-cooling. The water-cooling is essential to avoid aggressive temperature increases, both when using the high-speed and the laser equipment, and with laser it is especially necessary for ablation of enamel
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
This study aims to determine the most suitable type of heat exchanger to be applied to the water cooling the mold of a continuous casting process. Basically been studied four types of heat exchangers: shell and tube operating in counterflow, shell and tube operating in parallel flow, plate type and operating counterflow and plates operating in parallel flow. Initially is displayed design of heat exchangers for the conditions of the proposed application. With the heat exchangers dimensioned comparisons were made in order to set the heat exchanger more suitable for application. In the study, one comes to the conclusion that the plate type heat exchangers operating shows counterflow major advantage for this application
Resumo:
O objetivo deste trabalho foi avaliar a qualidade de produtos minimamente processados de mamão 'Formosa', fatias ou metades, armazenados sob diferentes temperaturas (3ºC, 6ºC e 9ºC). Utilizou-se de frutos que, depois de selecionados quanto ao grau de maturação e ausência de danos, foram lavados, desinfeccionados com cloro (200 mg.L-1) e armazenados a 12ºC, por 12 horas antes do processamento, que foi feito manualmente, a 12ºC. Os mamões, depois de descascados, foram cortados em fatias (5,0 x 2,5 cm) ou em metades longitudinais sem as pontas, que, depois de enxaguadas com água sanitizada (20 mg de cloro.L-1) e escorridas por 2-3 minutos, foram embaladas em bandejas de isopor recobertas com filme de PVC esticável (metades) ou em bandejas de tereftalato de polietileno - PET (fatias) e imediatamente armazenadas sob refrigeração. A avaliação destes produtos foi feita a cada 3 dias, quanto à resistência da polpa, coloração, pH e conteúdos de sólidos solúveis, acidez titulável, ácido ascórbico e de carboidratos, solúveis e de redutores. Durante o armazenamento, as fatias tenderam a se tornarem mais firmes, com a sua polpa apresentando pequeno escurecimento. Os conteúdos de carboidratos solúveis e de redutores e de sólidos solúveis não foram afetados pelo tipo de corte, temperatura de armazenamento ou embalagem. Durante o armazenamento, os teores de acidez titulável aumentaram nas fatias e diminuíram nas metades e observou-se influência da temperatura. Não se observaram reduções nos teores de ácido ascórbico durante o armazenamento, ou influência dos cortes ou das embalagens. Os produtos mantiveram-se adequados para comercialização até o 10º dia de armazenamento.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Pós-graduação em Engenharia Mecânica - FEB
Resumo:
The term refrigeration solar refers to any air conditioning system that uses solar energy as a primary energy source. The use of solar radiation for cooling purposes is divided according to their technological possibilities which are distinguished from one another as the way that energy is involved in the cycle, work or heat. The first case is related to vapor compression cycles, in which the work input is provided by the photovoltaic conversion of solar energy into electrical energy. In the second case, an absorption refrigeration cycle is used and the thermal energy collected from the solar radiation is provided at the generator of this cycle.. In this work a system with an absorption cycle using the pair BrLi-water, using solar energy as input is modeled. It is considered a simple refrigeration cycle whose the equations of mass and energy conservation in each component are developed in order to obtain an algebraic equation set and a simulation routine using the EES software. Although the simulation operates under certain specified thermal load it is possible to estimate the necessary areas of heat exchangers and solar collectors
Resumo:
This work presents a study of the absorption refrigeration system and the modeling and evaluation of two cycles using the binary solutions water-lithium bromide and ammonia-water for an equipment to be used in small size plants like residences. The study and evaluation aims the complete understanding of all parts of the system and the influence of each one of them as well as the spread of the knowledge to raise the use of this type of equipment in all sizes in order to decrease the energetic consumption of plants of all scales and making viable the alternative sources. The study is done in each element of the cycle separately and in some auxiliary equipments required in the operation such as the main power source, the solar collector. The software used for modeling, with emphasis on thermal part, was the EES (Engineering Equation Solver), that permitted the thermal balance calculus and acquisition of the used fluids properties. The results obtained for the equipment shows the system is more complex than the widely used in business, however, it can be viable and represents an alternative to increase the energetic efficiency
Resumo:
The use of refrigeration and air conditioning systems is of fundamental importance when it comes to air-conditioning of environments. Also important is the use of electricity for equipments’ operation related to these systems. Due to high cost of charging for this type of energy, factors economy and efficiency occupy key roles among design parameters of a system. One of the ways to get this economy is the use of a technique called thermal storage, or cold storage, which intends to move the required loads during peak time and also their equalizing, so that the energy is transferred from the peak time to non-peak time, thereby reducing the cost of energy consumed. Cold can be stored in the form of ice or ice water. This work aims to perform a technical-economic analysis of a mall located in Vale do Paraíba checking the feasibility of deploying a thermal storage system to achieve an economy in the cost of the energy used by the establishment. Through the parameters measured by the concessionaire of energy we can get the values of energy demand and power consumed, which will serve as basis for calculation for the study. The results obtained allow the development of two alternative proposals to the current configuration, one chosen by the criteria and results presented by technical-economic and energy analysis
Resumo:
Pós-graduação em Engenharia Mecânica - FEB
Resumo:
O Brasil ocupa uma posição de destaque como produtor e exportador de carne de frango. Um parâmetro importante na qualidade da carne de frango é a quantidade de água absorvida pela carcaça durante o processamento. No Brasil, o resfriamento das carcaças é feito por imersão em água refrigerada e, neste processo, a carcaça é reidratada, recuperando a água perdida durante o transporte e as operações iniciais. Este projeto teve como objetivo avaliar os fatores extrínsecos que podem influenciar a absorção de água pela carne de frango. Para isso, foram utilizados 144 frangos da linhagem Cobb, divididos em 24 grupos de seis aves. Aos 42 dias de idade, uma ave de cada grupo, com peso variando até 10% para mais ou para menos, em relação à média do grupo, foram abatidas em abatedouro experimental. A etapa de resfriamento foi realizada seguindo um delineamento inteiramente casualizado com arranjo fatorial 3x2, onde os fatores foram: três temperaturas na primeira seção do sistema de refrigeração (4, 10 e 16 º C) e dois graus de dureza da água (água dura e água mole), com seis tratamentos e quatro repetições. A legislação brasileira estabelece que a temperatura da água na primeira seção do resfriador não deve ser superior a 16ºC. Todas as carcaças permaneceram na primeira seção do resfriador durante 30 minutos e, em seguida, foram transferidas para outro tanque com água a 4ºC, permanecendo até atingir 7ºC. As carcaças foram pesadas antes e após o resfriamento por imersão, para avaliação da percentagem de água absorvida. A absorção de água foi influenciada pela temperatura inicial da água no pré-resfriador e pela dureza da água. Quando imersas inicialmente em água a 4ºC, as carcaças absorveram, em média, 2,70%, uma absorção significativamente menor do que a média de 3,83% observada nas carcaças que foram inicialmente imersas em água a 16ºC (p<0,05). As carcaças imersas em água a 10ºC apresentaram média de absorção de água de 3,66%, não diferindo das médias observadas nos outros tratamentos (p>0,05). Em água dura, a média de absorção de água foi de 2,46% e, em água mole, de 4,33% (p<0,05). Em todos os tratamentos, a absorção de água não excedeu o limite estabelecido pela legislação brasileira, que é de, no máximo, 8%. Esta informação é importante para controlar a absorção de água pelas carcaças em processamento de carne de frango, impedindo que os consumidores sejam prejudicados.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)