2 resultados para Água oleosa sintética

em Repositório Institucional UNESP - Universidade Estadual Paulista "Julio de Mesquita Filho"


Relevância:

100.00% 100.00%

Publicador:

Resumo:

A continuous flow reactor, inoculated with Aspergillus niger AN400, with total volume of 5 L was operated at 29 degrees C, with eight hours of retention hydraulic time and 150 L.h(-1) of air flow rate in order to remove 25 mg.L(-1) of Congo Red dye from a synthetic wastewater. The feeding of the reactor, inoculated with Aspergillus niger AN400, was done in two phases: Phase I, with 0,5 g/L of saccharose and Phase II, with no saccharose. In Phase I, it was possible to verify efficiencies of organic matter and color (mg Pt.L(-1)) removal of 80 +/- 16% and 82 +/- 10%, respectively. In Phase II, the efficiency of organic matter removal was 75 +/- 13% and color removal was 89 +/- 7%. The higher removals of nutrients were achieved by the reactor in Phase I with 25% to ammonia, 90% to nitrite, 93% to nitrate and 21% to phosphorus. Apparently, the presence of saccharose improved the removal of the nutrients.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This study was developed to evaluate the performance of different coagulant and pH dosages by applying the use of Dissolved Air Flotation (FAD) to enable its use in effluent treatment of the extraction process of palm oil. The study was developed in the laboratory, where studies about emulsions stability were made for the production of a synthetic effluent which best suit the characteristics of raw effluent. The synthetic water that would be used in the tests of FAD was produced, once the stability and characterization which best approached the raw wastewater was obtained. Trials tested three coagulant doses, combined with various pH ranges and five upward velocities (Va), finding an optimal range of this combination. Some operating parameters such as time and gradient of rapid mixing (20 s / 1000 s-1), time and gradient flotation (15 min / 60 s-1), chamber pressure saturation (450 kPa) and recirculation rate (20%) were set. In this way, samples were collected for analysis of the removal of turbidity parameters, suspended solids and oils and greases. This one is obtained by a correlation turbidity x oils and greases, referring to the previous analysis. The degree of removal obtained were 73,97% for turbidity, 51,4% for total suspended solids and 86,2% for oils and greases. Removal rates may be increased in later studies, by ranging the velocity gradient and flocculation parameters and the recirculation ratio, and by using lower flotation speeds to these effluent characteristics.