157 resultados para Validation séquentielle


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Despite the focus on facial photoaging ratings, there are few classifications developed for forearm skin aging assessment.Objective: To develop and validate a clinical scale for the evaluation of forearm skin aging.Methods: Three clinical dermatology faculty members selected, discussed, and appraised the main signs of forearm photoaging. The validation of the resulting scale was performed by 5 assessors who were previously trained to classify 102 photographs of forearms with different degrees of aging. Retests were performed in 15 days.Results: There was significant correlation between the selected variables and the subjective global aging scale. The developed scale showed high internal consistency (Cronbach's alpha = 0.87) and high correlation with the global photoaging scale (rho = 0.92). Inter- and intraobserver final scores showed high agreement.Conclusion: A validated clinical photoaging scale for forearms with internal consistency, reliability, and validity was developed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study developed a Color Scale of Perceived Exertion (RPE-color scale) and assessed its concurrent and construct validity in adult women. One hundred participants (18-77 years), who were habitual exercisers, associated colors with verbal anchors of the Borg RPE scale (RPE-Borg scale) for RPE-color scale development. For RPE-color scale validation, 12 Young (M = 21.7 yr., SD = 1.5) and 10 Older (M = 60.3 yr., SD = 3.5) adult women performed a maximal graded exercise test on a treadmill and reported perceived exertion in both RPE-color and RPE-Borg scales. In the Young group, the RPE-color scale was significantly associated with heart rate and oxygen consumption, having strong correlations with the RPE-Borg scale. In the Older group, the RPE-color scale was significantly associated with heart rate, having moderate to high correlations with the RPE-Borg scale. The RPE-color scale demonstrated concurrent and construct validity in the Young women, as well as construct validity in Older adults.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

It was studied the trapezius muscle and serratus anterior muscle in 24 male volunteers using a 2-channel TECA TE 4 electromyograph and Hewlett Packard surface electrodes, during the execution of four different modalities of military press exercises with open grip. The results showed that TS acted significantly in the modalities standing and sitting press behind neck, while SI acted in all the modalities, i.e., standing and sitting press behind neck and forward, justifying their inclusion as basic exercises for physical conditioning programmes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To validate a model for investigating the effects of analgesic drugs on mechanical, thermal and electrical stimulation testing. To investigate repeatability, sensitivity and specificity of nociceptive tests. Randomised experiment with 2 observers in 2 phases. Mechanical (M), thermal (TL) and electrical (E) stimuli were applied to the dorsal metacarpus (M-left and TL-right) and coronary band of the left thoracic limb (E) and a thoracic thermal stimulus (TT) was applied caudal to the withers in 8 horses (405 ± 43 kg). Stimuli intensities were increased until a clear avoidance response was detected without exceeding 20 N (M), 60°C (TL and TT) and 15 V (E). For each set of tests, 3 real stimuli and one sham stimulus were applied (32 per animal) using a blinded, randomised, crossover design repeated after 6 months. A distribution frequency and, for each stimulus, Chi-square and McNemar tests compared both the proportion of positive responses detected by 2 observers and the 2 study phases. The κ coefficients estimated interobserver agreement in determining endpoints. Sensitivity (384 tests) and specificity (128 tests) were evaluated for each nociceptive stimulus to assess the evaluators' accuracy in detecting real and sham stimuli. Nociceptive thresholds were 3.1 ± 2 N (M), 8.1 ± 3.8 V (E), 51.4 ± 5.5°C (TL) and 55.2 ± 5.3°C (TT). The level of agreement after all tests, M, E, TL and TT, was 90, 100, 84, 98 and 75%, respectively. Sensitivity was 89, 100, 89, 98 and 70% and specificity 92, 97, 88, 91 and 94%, respectively. The high interobserver agreement, sensitivity and specificity suggest that M, E and TL tests are valid for pain studies in horses and are suitable tools for investigating antinociceptive effects of analgesics in horses.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An accurate, sensitive, precise and rapid reversed-phase high-performance liquid chromatographic method was successfully developed and validated for the determination of caffeic acid (CA) in emulsions. The best separation was achieved on a 250 × 4.6 mm, 5.0 µm particle size RP18 XDB Waters column using ethanol and purified water (40:60 v/v) adjusted to pH 2.5 with acetic acid as the mobile phase at a flow rate of 0.7 mL/min. Ultraviolet detection was performed at 325 nm at ambient column temperature (25°C). The method was linear over the concentration range of 10-60 µg/mL (r(2) = 0.9999) with limits of detection and quantification of 1.44 and 4.38 µg/mL, respectively. CA was subjected to oxidation, acid, base and neutral degradation, as well as photolysis and heat as stress conditions. There were no interfering peaks at or near the retention time of CA. The method was applied to the determination of CA in standard and pharmaceutical products with excellent recoveries. The method is applicable in the quality control of CA.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A method for the identification and quantification of pesticide residues in water, soil, and sediment samples has been developed, validated, and applied for the analysis of real samples. The specificity was determined by the retention time and the confirmation and quantification of analyte ions. Linearity was demonstrated over the concentration range of 20 to 120 µg L(-1), and the correlation coefficients varied between 0.979 and 0.996, depending on the analytes. The recovery rates for all analytes in the studied matrix were between 86% and 112%. The intermediate precision and repeatability were determined at three concentration levels (40, 80, and 120 µg L(-1)), with the relative standard deviation for the intermediate precision between 1% and 5.3% and the repeatability varying between 2% and 13.4% for individual analytes. The limits of detection and quantification for fipronil, fipronil sulfide, fipronil-sulfone, and fipronil-desulfinyl were 6.2, 3.0, 6.6, and 4.0 ng L(-1) and 20.4, 9.0, 21.6, and 13.0 ng L(-1), respectively. The method developed was used in water, soil, and sediment samples containing 2.1 mg L(-1) and 1.2% and 5.3% of carbon, respectively. The recovery of pesticides in the environmental matrices varied from 88.26 to 109.63% for the lowest fortification level (40 and 100 µg kg(-1)), from 91.17 to 110.18% for the intermediate level (80 and 200 µg kg(-1)), and from 89.09 to 109.82% for the highest fortification level (120 and 300 µg kg(-1)). The relative standard deviation for the recovery of pesticides was under 15%.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A GC method to determine caprolactam in water, 15 ethanol, and olive oil food simulants was developed and validated. Linear ranges varied from 0.96 to 642.82 g/mL for water, 0.64 to 800.32 g/mL for 15 ethanol, and 1.06 to 1062.34 g/g for olive oil, with correlation coefficients higher than 0.999. Method precision studies showed RSD values lower than 5.45, while method accuracy studies showed recovery from 72 to 111 for all simulants. The effect of gamma irradiation on caprolactam migration from multilayer polyamide 6 (PA-6) films intended for cheese into water, 15 ethanol, olive oil, and 3 acetic acid simulants was also studied. For migration assay, non-irradiated and irradiated (12 kGy) films were placed in contact with the simulant and exposed at 40C for 10 days. The validated method was used to quantify caprolactam migration from multilayer PA-6 films into the simulants, which ranged from 1.03 to 7.59 mg/kg for non-irradiated films, and from 4.82 to 11.32 mg/kg for irradiated films. Irradiation caused almost no changes in caprolactam levels, with the exception of olive oil, which showed an increase in the caprolactam level. All multilayer PA-6 films were in accordance with the requirements of the legislation for caprolactam migration.