202 resultados para Usuário de implante coclear
Resumo:
Pós-graduação em Psicologia - FCLAS
Resumo:
The purpose of this paper was to evaluate the influence of different implant designs on the micromovements of immediately placed implants. CT-based finite element models comprising an upper central incisor socket and four commercially available internal connection implant designs (SIN SW®, 3i Certain®, Nobel ReplaceTM, and RN synOcta® ITI Standard) of comparable diameter and length were constructed. 50, 100 and 200N magnitude loads were applied over the implant. ANOVA at 95% level of significance was used to evaluate bone to implant relative displacement (micromovements). The implant design (68,80%) greatly influences the micromovement of immediately placed implants. However, the loading magnitude (68,80%) is the most important factor regarding the implant stability in this protocol.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Pós-graduação em Odontologia - FOA
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Pós-graduação em Pesquisa e Desenvolvimento (Biotecnologia Médica) - FMB
Resumo:
Studies have reported that alcohol may lead to imbalance in bone formation and resorption, however, its effects on osseointegration of titanium implants continues to be an inconclusive subject. In this context, the aim of this study was to make a biomechanical evaluation of the effect of abusive alcohol consumption on the removal torque of osseointegrated titanium implants. Male Wistar rats (n=30) were divided into two experimental groups (15 each) receiving only water (Control) or 36% alcohol solution oral administration. Thirty days later, all animals were submitted to titanium implant (2.2 mm x 4 mm) placement in the right and left tibiae. The surgical alveoli were prepared with a 2 mm drill mounted in a counter-angle hand-piece (20:1 ratio, 35 Ncm torque at 1200 rpm) under abundant cooling. Five animals from each group were euthanized at 15, 30, and 60 days. Tibiae were submitted to reverse torque analysis. Data obtained were submitted to statistical analysis by the non-parametric Kruskal-Wallis and Dunn Tests (p < 0.05). Animals in the alcohol group presented lower removal torque values when compared with control group animals for all periods tested (p < 0.05). It can be concluded that abusive alcohol consumption can reduce the removal torque of titanium implants placed in rat tibiae, suggesting that alcohol may interfere in the osseointegration process of titanium implants.
Resumo:
Indirect composite resin systems have been routinely recommended for making restorations in distressed patients. The purpose of this study was to evaluate histologically in rats the effect of chronic stress on the reaction of subcutaneous connective tissue after implant of Artglass™. For this purpose, 60 rats were divided into four groups (GI (control), GII (stressed), GIII (Artglass™) and GIV (Artglass™. / stressed) received dorsal subcutaneous implants of polyethylene tubes containing saline solution (GI and GII) or Artglass™ (GIII and GIV). In groups of four animals were sacrificed at 7,14 and 28 days postoperatively. The results allowed to observe more intense inflammatory reaction and tissue organization later in the animals subjected to stress.
Resumo:
One of the complications that concern prosthetists is bone loss peri-implant, because the success of dental implant treatment requires long-term maintenance of hard and soft tissues around the implant. Whereby the dental implants have not only the goal of restoring function, but also the aesthetics of the patient, the bone loss peri-implant can dramatically compromise the aesthetics of rehabilitation, particularly in anterior regions. The aim of this study was to analyze and reason, through literature review, the main factors that can cause bone loss in peri-implant and possible ways to prevent it.
Resumo:
With the advances of osseointegration principles, the use of implant-supported prosthesis has become a routine treatment option. The success of an implant is initially associated to the surgical technique, primary stability and absence of bacterial contamination on the implant site. Subsequently, the absence of mechanical trauma (overload) and peri-implantitis are sine qua non conditions to the longitudinal success of implant treatment. Therefore, the strict maintenance of oral hygiene is highly important to avoid biofilm accumulation around the implant and consequently to provide last-long implant-supported dentures. The clinician has the responsibility to supply a favorable prognosis to the patient so that the rehabilitation succeed. For this reason, during prosthesis fabrication the clinician should observe the design and emergency profile of the prosthesis, the peri-implant sulcus depth as well as the presence of motor or psychological impairment by the patient. Subjects with missing teeth and that will be submitted to the implant treatment should be motivated and adequate instructed regarding oral hygiene and its importance since the best option to obtain treatment longevity and consequently patient’s satisfaction is the prevention. Therefore, this study aimed to perform a literature review about the hygiene of implant-supported prosthesis.
Resumo:
Removable partial denture improve functional and aesthetic failures caused by partial loss of teeth, however specific characteristics of each patients can determine the success of treatment, especially with regard to the support of the prosthesis, which may depend on teeth, the combination of teehe and mucosa and currently associated with the dental implants. The aim of this study is report a case in which there was the need of the association, to enable better aesthetics and self-esteem to the patients. After implant placement and fabrication of prosthetic patient reported satisfaction with the rehabilitation treatment, improving their quality of life.