378 resultados para Trasplante renal


Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study was designed to analyze the impact of diminished renal perfusion pressure due to renal clipping on the rat model of adriamycin nephropathy. Male Wistar rats, divided into four groups (n = 9 per group) were injected with saline as control (C), adriamycin 3 ml/kg (Ad), saline with the left renal artery clipped (Rv), and adriamycin plus clip (AdRv). After 24 weeks mean arterial pressure (MAP), inulin, and p-aminohippurate (PAH) clearances were performed to evaluate renal function. Morphologic analysis included histologic criteria of percentage of glomerulosclerosis and tubulointerstitial lesion index (TILI). The MAP (mm Hg) was similar between Rv (143 +/- 13) and AdRv (154 +/- 20), but higher (P < .05) than C (120 +/- 8) and Ad (124 +/- 11). Inulin clearance (mL/min/100 g) in Ad (0.2 +/- 0.05) was smaller than in C (0.53 +/- 0.17) and Rv (0.4 +/- 0.01) (P < .05), and was at an intermediate level in AdRv (0.33 +/- 0.2). The level of PAH (mL/min/100 g) was normal at 1.76 in C, and diminished more in Ad (0.58) than in Rv (1.06) and AdRv (1.18) (P < .05). Both Ad and the AdRv nonclipped kidneys had the highest degree of glomerulosclerosis (33% and 25%) and TILI (7% and 8%), respectively, compared with C and Rv (both 0%), whereas the clipped kidneys displayed intermediate degrees (9% and 5%) (P < .05 v nonclipped). The data suggest that diminished perfusion pressure of the clipped kidney, by decreasing the intraglomerular pressure, protects the glomerulus from damage and attenuates the evolution of adriamycin nephropathy. Am J Hypertens 1998;11:1124-1128 (C) 1998 American Journal of Hypertension, Ltd.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Atherosclerotic renal artery stenosis (RAS) and coronary artery disease (CAD) arise from the same multiple risk factors. The purpose of this study was to assess the frequency of previously undiagnosed CAD in patients with angiographically confirmed RAS, by conducting coronary arteriography in the same setting. of 57 consecutive patients referred for renal arteriography on clinical grounds during a 14-month period, 28 had no RAS and 6 had RAS, but previously documented CAD. of the remainder 23 patients. 17 (74%; CI 56%-92%) had both RAS and CAD (7 single vessel, 4 two-vessel, and 7 multivessel disease). The clinical characteristics, such as age, blood pressure (BP) levels, signs of heart failure, were no different between those with and without CAD, although the 4 diabetic patients, the 4 patients with fundoscopic findings of grade III retinopathy, 11 of 14 with peripheral arterial disease, and 7 of 8 patients with prior stroke belonged in the CAD group. None developed complications as a result of the two consecutive procedures. The data suggest that in patients with RAS the frequency of silent CAD is high and cannot be predicted on clinical grounds alone, therefore coronary angiography should be routinely recommended in the same setting.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Renoguanylin (REN) is a recently described member of the guanylin family, which was first isolated from eels and is expressed in intestinal and specially kidney tissues. In the present work we evaluate the effects of REN on the mechanisms of hydrogen transport in rat renal tubules by the stationary microperfusion method. We evaluated the effect of 1 mu M and 10 mu M of renoguanylin (REN) on the reabsorption of bicarbonate in proximal and distal segments and found that there was a significant reduction in bicarbonate reabsorption. In proximal segments, REN promoted a significant effect at both 1 and 10 mu M concentrations. Comparing control and REN concentration of 1 mu M, JHCO(3)(-) . nmol cm(-2) s(-1) -1,76 +/- 0.11(control) x 1,29 +/- 0,08(REN) 10 mu m: P<0.05, was obtained. In distal segments the effect of both concentrations of REN was also effective, being significant e.g. at a concentration of 1 mu M (JHCO(3)(-), nmol cm(-2) s(-1) -0.80 +/- 0.07(control) x 0.60 +/- 0.06(REN) 1 mu m; P<0.05), although at a lower level than in the proximal tubule. Our results suggest that the action of REN on hydrogen transport involves the inhibition of Na(+)/H(+) exchanger and H(+)-ATPase in the luminal membrane of the perfused tubules by a PKG dependent pathway. (c) 2009 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVETo determine the current status of the literature regarding the clinical efficacy and complication rates of cryoablation vs radiofrequency ablation in the treatment of small renal tumours.METHODSA review of the literature was conducted. There was no language restriction. Studies were obtained from the following sources: MEDLINE, EMBASE and LILACS.Inclusion criteria were (i) case series design with more than one case reported, (ii) use of cryoablation or radiofrequency ablation, (iii) patients with renal cell carcinoma and, (iv) outcome reported as clinical efficacy.When available, we also quantified the complication rates from each included study.Proportional meta-analysis was performed on both outcomes with a random-effects model. The 95% confidential intervals were also calculated.RESULTSThirty-one case series (20 cryoablation, 11 radiofrequency ablation) met all inclusion criteria.The pooled proportion of clinical efficacy was 89% in cryoablation therapy from a total of 457 cases. There was a statistically significant heterogeneity between these studies showing the inconsistency of clinical and methodological aspects.The pooled proportion of clinical efficacy was 90% in radiofrequency ablation therapy from a total of 426 cases. There was no statistically significant heterogeneity between these studies.There was no statistically significant difference regarding complications rate between cryoablation and radiofrequency ablation.CONCLUSIONSThis review shows that both ablation therapies have similar efficacy and complication rates.There is urgency for performing clinical trials with long-term data to establish which intervention is most suitable for the treatment of small renal masses.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background. Gastrointestinal (GI) complications are common after renal transplantation, mainly owing to immunosuppressive therapy. Assessment of GI transit time can facilitate rational management of these disorders.Objective. We evaluate the GI transit parameters in renal transplant recipients taking tacrolimus, azathioprine, and prednisone with the use of the alternate current biosusceptometry (ACB) technique and compared them with healthy volunteers.Methods. Ten renal transplant recipients and 10 healthy volunteers were enrolled in this study. After an overnight fast, patients and volunteers ingested a standard meal containing magnetic markers. The biomagnetic monitoring was performed at 10-minute intervals for at least 8 hours to obtain gastric emptying as well as the colonic arrival time-intensity curves. Mean gastric emptying time (MGET), mean colon arrival time (MCAT), and mean small intestinal transit time (MSITT) were quantified and compared between control and patient groups with results expressed as mean +/- SD.Results. The MGET measured by the ACB technique was 48 +/- 31 minutes and 197 +/- 50 minutes for patients and healthy subjects, respectively. MSITT and MCAT values calculated for patients versus volunteers were 171 +/- 71 minutes versus 197 +/- 71 minutes and 219 +/- 83 minutes versus 373 +/- 52 minutes, respectively. Renal transplant recipients showed significantly faster; gastric emptying and colon arrival times (P < .001) compared with normal volunteers; however, small intestinal transit time was not significantly different (P = .44).Conclusions. In stable renal transplant recipients, the GI transit parameters were significantly faster than in normal healthy volunteers. ACB sensors are versatile technologies that can be used for clinical research, because they offer an excellent opportunity to evaluate GI transit in a noninvasive manner without the use of ionizing radiation.