262 resultados para TITANIUM ENDODONTIC INSTRUMENTS


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Statement of problem. Titanium has physical and mechanical properties, which have led to its increased use in dental prostheses despite casting difficulties due to high melting point and formation of oxide layers which affect the metal-ceramic bond strength.Purpose. This in vitro study evaluated the shear bond strength of the interface of 2 dental porcelains and pure titanium injected into a mold at 3 different temperatures.Material and methods. Using commercially pure (cp) titanium bars (Titanium, Grade I) melted at 1668degreesC and cast at mold temperatures of 430degreesC, 700degreesC or 900degreesC, 60 specimens were machined to 4 x 4 mm, with a base of 5 x 1 mm. The 4-mm surfaces were airborne-particle abraded with 100 mum aluminum oxide before applying and firing the bonding agent and evaluating the 2 porcelains (Triceram/Triline ti and Vita Titankeramik). Ten specimens were prepared for each temperature and porcelain combination Shear bond testing was performed in a universal testing machine, with a 500-kg load cell and crosshead speed of 0.5 mm/min. The specimens were loaded until failure. The interfaces of representative fractured specimens of each temperature were examined with a scanning electron microscope (SEM) and energy dispersive spectrometer (EDS). Data for shear bond strength (MPa) were statistically analyzed by 2-way ANOVA and the Tukey test (alpha = .05).Results. The results showed significant differences for the metal/porcelain interaction effect (P = .0464). There were no significant differences for the 2 porcelains (P = .4250). The Tukey test showed a significant difference between the pair cp Ti 430degreesC Triceram and cp Ti 900degreesC Triceram, with respective mean values and SDs of 59.74 +/- 11.62 and 34.03 +/- 10.35 MPa.Conclusion. Triceram porcelain showed a bond strength decrease with an increase in the mold temperature for casting titanium. The highest bond strength for Vita porcelain and the best metal-ceramic interface observed with the SEM were found with the mold temperature of 700degreesC.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The cathodic behaviour of oxides formed on titanium electrodes in physiological solutions at potentials between 3 and 5 V (vs. SCE) was studied by cyclic voltammetry. In case of anodic polarization at potentials higher than 3 V (vs. SCE), a cathodic peak at similar to 0.4 V (vs. SCE) appears in the cathodic scan, which could be due to the reduction of unstable peroxides. The results show that this peak depends on the anodic potential and the oxidation time. This behaviour supposedly is due to the formation of unstable titanium peroxides like TiO3 during anodization. Based on repetitive oxidation-reduction processes can be concluded that the created amount of TiO3 inside of the TiO2 surface layer seems to be constant. (c) 2006 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective. The objective of this study was to evaluate the effects of endodontic irrigants on endotoxins in root canals.Study design. Ninety-eight single-root human teeth were used. Escherichia coli endotoxin was inoculated into 84 root canals. All root canals were enlarged and assigned to 7 groups (n = 14), according to solution used. Group 1 (G1): 2.5% NaOCl; G2: 5.25% NaOCl; G3: 2% chlorhexidine; G4: 0.14% calcium hydroxide; G5: polymyxin B; G6: positive control, saline solution; G7: negative control (no endotoxin). Two samplings of root canal were accomplished: immediate and after 7 days. Detoxification of endotoxin was evaluated by Limulus assay and antibody production in B-lymphocyte culture. Results were analyzed by Kruskal-Wallis/Dunn and ANOVA/Tukey.Results. At the immediate and second samplings, groups G4, G5, and G7 presented the best results, significantly different from groups G1, G2, G3, and G6 (P = .05).Conclusions. Calcium hydroxide and polymyxin B detoxified endotoxin in root canals and altered properties of LPS to stimulate the antibody production by B-lymphocytes. Sodium hypochlorite and chlorhexidine did not detoxify endotoxin.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aim the aim of this study was to evaluate the inflammatory response to irrigating solutions injected into the peritoneal cavity of mice.Methodology Sixty mice received intra-peritoneal injections of 0.3 mL of 0.5% sodium hypochlorite, 2.0% chlorhexidine digluconate or phosphate buffered saline (PBS, control). Five animals of each group were sacrificed at 4, 24, 48 h and 7 days after the injection. Liquid from the peritoneal cavity of each animal was collected for the total and differential counting of inflammatory cells and protein leakage.Results the 0.5% sodium hypochlorite solution group had greater migration of neutrophils and mononuclear cells to the peritoneal cavity from 48 to 168 h (P < 0.05). There was a significant increase in protein leakage to the peritoneal cavity after 4 up to 48 h in the 0.5% sodium hypochlorite group compared to the control group. Protein leakage was similar in all groups at 168 h. The 2.0% chlorhexidine group had similar results to the control group at all time periods.Conclusions the 0.5% sodium hypochlorite solution induced an inflammatory response, however, the 2.0% chlorhexidine digluconate solution did not induce a significant inflammatory response.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A significant proportion of oral bacteria are unable to undergo cultivation by existing techniques. In this regard, the microbiota from root canals still requires complementary characterization. The present study aimed at the identification of bacteria by sequence analysis of 16S rDNA clone libraries from seven endodontically infected teeth. Samples were collected from the root canals, subjected to the PCR with universal 16S rDNA primers, cloned and partially sequenced. Clones were clustered into groups of closely related sequences (phylotypes) and identification to the species level was performed by comparative analysis with the GenBank, EMBL and DDBJ databases, according to a 98 % minimum identity. All samples were positive for bacteria and the number of phylotypes detected per subject varied from two to 14. The majority of taxa (65(.)2 %) belonged to the phylum Firmicutes of the Gram-positive bacteria, followed by Proteobacteria (10(.)9 %), Spirochaetes (4(.)3 %), Bacteroidetes (6(.)5 %), Actinobacteria (2(.)2 %) and Deferribacteres (2(.)2 %). A total of 46 distinct taxonomic units was identified. Four clones with low similarity to sequences previously deposited in the databases were sequenced to nearly full extent and were classified taxonomically as novel representatives of the order Clostridiales, including a putative novel species of Mogibacterium. The identification of novel phylotypes associated with endodontic infections suggests that the endodontium may still harbour a relevant proportion of uncharacterized taxa.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study compared the remaining filling material and working time when removing gutta-percha/AH 26 and Resilon/Epiphany from root filled extracted teeth. The root fillings were removed using chloroform and two different rotary systems (K3 and Liberator files). The amount of residual filling material on the canal walls was imaged and measured using image analyzer software. The group filled with Resilon/Epiphany and retreated with K3 files demonstrated the least residual filling material on the walls (p < 0.05). There was no statistically significant difference between the guttapercha/AH26 and Resilon/Epiphany groups when the Liberator files were used (p > 0.05). In the groups filled with Resilon/Epiphany, the filling was removed faster than groups filled with gutta-percha/AH 26 (p < 0.05). K3 rotary system was faster than Liberator to remove both gutta-percha and Resilon (p < 0.05). Resilon/ Epiphany was effectively removed with K3 or Liberator rotary files.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective. The objective of this study was to compare the in vitro antimicrobial activity of 2% chlorhexidine gel against Enterococcus faecalis with sodium hypochlorite in 2 different concentrations (1.5% and 5.25%).Study design. Eighty human lower premolars with single root canals were prepared, autoclaved, and infected for 7 days with E. faecalis monocultures. The roots were then separated into 5 experimental groups according to the irrigant solution used during the standardized preparation. To assess the antimicrobial action of the irrigant solutions, 3 microbial samples were taken: S1-initial (before the biomechanical preparation), S2-posttreatment (immediately after the biomechanical preparation), and S3-final (7 days after the biomechanical preparation). The microbiological samples were plated to count the colony-forming units (CFU).Results. The 2% chlorhexidine gel and 5.25% sodium hypochlorite significantly reduced the E. faecalis CFU in the posttreatment and final microbiological samples. The 1.5% sodium hypochlorite also reduced the E. faecalis CFU immediately after the root canal instrumentation, but the E. faecalis CFU increased in the final sample showing no statistical difference from the control group.Conclusion. The 2% chlorhexidine gluconate gel and 5.25% sodium hypochlorite were effective in eliminating E. faecalis even 7 days after the instrumentation; moreover, the higher the concentration of sodium hypochlorite the better its antimicrobial action.