158 resultados para STRAND BREAK REPAIR


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives: To evaluate the efficacy and safety of enhanced recovery after surgery (ERAS) programs in elective open surgical repair (OSR) of abdominal aortic aneurysm (AAA).Background: Open surgical repair of AAA is associated with high morbidity and mortality, prolonged hospital stay and high costs. ERAS programs contribute to the optimization of treatment by reducing hospital stay and improving clinical outcomes.Methods: A review of PubMed, EMBASE and LILACS databases was conducted. As only one randomized controlled trial was found, a pooled analysis of proportions from case series was conducted, considering it a complementary overview of the topic. Inclusion criteria were case series with more than five cases reported, adult patients who underwent an elective OSR of AAA and use of an ERAS program. ERAS was compared to conventional perioperative care. The pooled proportion and the confidence interval (CI) are shown for each outcome. The overlap of the CI suggests similar effect of the interventions studied.Results: Thirteen case series studies with ERAS involving 1,250 patients were compared to six case series with conventional care with a total of 1,429 patients. The pooled, respective proportions for ERAS and conventional care were: mortality, 1.51% [95% CI: 0.0091, 0.0226] and 3.0% [95% CI 0.0183, 0.0445]; and incidence of complications, 3.82% [95% CI 0.0259, 0.0528] and 4.0% [95% CI 0.03, 0.05].Conclusion: This review shows that ERAS and conventional care therapies have similar mortality and complication rates in OSR of AAA.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: The sandwich technique is an endovascular off-the-shelf solution for patients with thoracoabdominal aortic aneurysms (TAAAs). In a sandwich configuration, the chimney stent runs in the middle of a space created by two or three aortic endografts.Methods: All patients with TAAAs who were treated with the sandwich technique were included in the study. Self-expanding Viabahn grafts (W. L. Gore and Associates Inc, Flagstaff, Ariz) were used as parallel grafts in the renal arteries and visceral vessels. Caudad-facing chimney grafts were used for the visceral arteries and cephalad-facing periscope grafts for the renal arteries.Results: During the study period, 32 patients with TAAAs were treated with sandwich grafts. Indication for the procedure in 43% was an acute onset of symptoms, including two patients with a rupture and a retroperitoneal hematoma. Three patients required an additional debranching procedure. A total of 104 chimney grafts were implanted. Two patients died postoperatively because of the operation. Major adverse events were recorded in five patients, including one patient with persistent paraplegia and two with permanent renal failure requiring dialysis. The incidence of chimney graft occlusion was higher in patients with three or four parallel grafts than in those with two chimney grafts only. Patients with chronic dissections had a 12-times higher incidence of chimney graft occlusion than aneurysm patients. The number of patients with type I or III endoleaks was higher in the group with three or four parallel grafts.Conclusions: The sandwich technique is an off-the-shelf endovascular alternative to treat patients with TAAAs in an emergent setting. The combination of chimney grafts with a periscope configuration enables a rapid endovascular aneurysm exclusion with acceptable midterm results.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Problem The most common DNA lesion generated by oxidative stress (OS) is 7, 8-dihydro-8-oxoguanine (8-oxoG) whose excision repair is performed by 8-oxoguanine glycosylase (OGG1). We investigated OGG1 expression changes in fetal membranes from spontaneous preterm birth (PTB) and preterm premature rupture of the membranes (pPROM) and its changes in vitro in normal fetal membranes exposed to OS inducer water-soluble cigarette smoke extract (CSE). Method of study DNA damage was determined in amnion cells treated with CSE by comet and FLARE assays. OGG1 mRNA expression and localization in fetal membranes from clinical specimens and in normal term membranes exposed to CSE were examined by QRT-PCR and by immunohistochemistry. Results DNA strand and base damage was seen in amnion cells exposed to CSE. OGG1 expression was 2.5-fold higher in PTB samples compared with pPROM (P=0.045). No significant difference was seen between term and pPROM or PTB and term. CSE treatment showed a nonsignificant decrease in OGG1. OGG1 was localized to both amnion and chorion with less intense staining in pPROM and CSE-treated membranes. Conclusion Increased OS-induced DNA damage predominated by 8-oxoG is likely to persist in fetal cells due to reduced availability of base excision repair enzyme OGG1. This can likely lead to fetal cell senescence associated with some adverse pregnancy outcome.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: This study evaluated the effect of different surface conditioning protocols on the repair strength of resin composite to the zirconia core / veneering ceramic complex, simulating the clinical chipping phenomenon.Materials and Methods: Forty disk-shaped zirconia core (Lava Zirconia, 3M ESPE) (diameter: 3 mm) specimens were veneered circumferentially with a feldspathic veneering ceramic (VM7, Vita Zahnfabrik) (thickness: 2 mm) using a split metal mold. They were then embedded in autopolymerizing acrylic with the bonding surfaces exposed. Specimens were randomly assigned to one of the following surface conditioning protocols (n = 10 per group): group 1, veneer: 4% hydrofluoric acid (HF) (Porcelain Etch) + core: aluminum trioxide (50-mu m Al2O3) + core + veneer: silane (ESPE-Sil); group 2: core: Al2O3 (50 mu m) + veneer: HF + core + veneer: silane; group 3: veneer: HF + core: 30 mu m aluminum trioxide particles coated with silica (30 mu m SiO2) + core + veneer: silane; group 4: core: 30 mu m SiO2 + veneer: HF + core + veneer: silane. Core and veneer ceramic were conditioned individually but no attempt was made to avoid cross contamination of conditioning, simulating the clinical intraoral repair situation. Adhesive resin (VisioBond) was applied to both the core and the veneer ceramic, and resin composite (Quadrant Posterior) was bonded onto both substrates using polyethylene molds and photopolymerized. After thermocycling (6000 cycles, 5 degrees C-55 degrees C), the specimens were subjected to shear bond testing using a universal testing machine (1 mm/min). Failure modes were identified using an optical microscope, and scanning electron microscope images were obtained. Bond strength data (MPa) were analyzed statistically using the non-parametric Kruskal-Wallis test followed by the Wilcoxon rank-sum test and the Bonferroni Holm correction (alpha = 0.05).Results: Group 3 demonstrated significantly higher values (MPa) (8.6 +/- 2.7) than those of the other groups (3.2 +/- 3.1, 3.2 +/- 3, and 3.1 +/- 3.5 for groups 1, 2, and 4, respectively) (p < 0.001). All groups showed exclusively adhesive failure between the repair resin and the core zirconia. The incidence of cohesive failure in the ceramic was highest in group 3 (8 out of 10) compared to the other groups (0/10, 2/10, and 2/10, in groups 1, 2, and 4, respectively). SEM images showed that air abrasion on the zirconia core only also impinged on the veneering ceramic where the etching pattern was affected.Conclusion: Etching the veneer ceramic with HF gel and silica coating of the zirconia core followed by silanization of both substrates could be advised for the repair of the zirconia core / veneering ceramic complex.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work aims at presenting a no-break system for microcomputers using ultracapacitors in replacement of the conventional chemical batteries. We analyzed the most relevant data about average power consumption of microcomputers, electrical and mechanical characteristics of ultracapacitors and operation of no-break power circuits, to propose a configuration capable of working properly with a microcomputer switching mode power supply. Our solution was a sixteen-component ultracapacitor bank, with a total capacitance of 350 F and voltage of 10.8 V, adequate to integrate a low-capacity no-break system, capable of feeding a load of 180 Wh, during 75 s. Our proposed no-break increases the reliability of microcomputers by reducing the probability of user data losses, in case of a power grid failure, offering, so, a high benefit-cost ratio. The replacement of the battery by ultracapacitors allows a quick no-break recharge and low maintenance costs, since these modern components have a lifetime longer than the batteries. Moreover, this solution reduces the environmental impact and eliminates the constant recharge of the energy storage device.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The fracture of porcelain structures have been related in either natural dentition or implant-supported restorations. Techniques using a composite resin or indirect methods can be used. This article presents a porcelain fracture on implant-supported metal-ceramic restoration. IPS Empress e.max laminate veneer restoration was used to repair the fracture. With this technique, it was possible to restore aesthetics and function, combined with low cost and patient satisfaction.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The comet assay is a method of DNA damage analysis widely used to quantify oxidative damage, crosslinks of DNA, apoptosis and genotoxicity of chemicals substances as chemical, pharmaceuticals, agrochemicals products, among others. This technique is suitable to detect DNA strand breaks, alkali-labile sites and incomplete excision repair sites and is based on the migration of DNA fragments by microeletroforesis, DNA migrates for the anode forming a “tail”, and the formed image has the appearance of a comet. The slides can be stained with fluorescence or silver, having differences in the microscopy type used for the analysis and the possibility of storage of the slides, moreover, the first one is a stained-method with more difficulties of accomplishment. The image analysis can be performed by a visual way, however, there is a disadvantage as the subjectivity on the results, that can be minimized by an automated method of digital analysis. This process was studied in this report with the aim to perceive the validation of the digital analysis turning it a quantitative method with larger reproductibility, minimizing the variability and imprecision due to the subjective analysis. For this validation we selected 50 comets photographed in a standardized way and printed, afterwards, pictures were submitted to three experienced appraisers, who quantified them manually. Later, the images were processed by free software ImageJ 1.38x, printed and quantified manually by the same appraisers. The intraclass correlation was higher to comet measures after image processing. Following, an algorithm of automated digital analysis from the measures of the comet was developed; the values obtained were compared with those 12 estimated manually after the processing resulting high correlation among the measures. The use of image analysis systems increases ...(Complete abstract click electronic access below)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to evaluate and compare the repair of bone defects filled with calcium aluminate cement (EndoBinder), mineral trioxide aggregate (MTA), and calcium hydroxide. Methods After mixing, the cements were inserted into bone defects (3.3 mm) mechanically created in the right and left tibias of 30 rats (Rattus norvegicus, Wistar). In the control group, the bone defects were filled with blood clot of the animal itself. After time intervals of 7, 30, and 90 days had elapsed, bone tissue biopsies (n = 5) were surgically obtained and submitted to laboratory processing. The response of bone tissue in contact with the materials was microscopically analyzed. The percentage of neoformed bone tissue in the defect was determined by means of planimetry counting points superimposed on the histologic image. Results Significant increase in the percentage of neoformed bone tissue was observed throughout the experimental periods in all groups (P < .05). For the cements EndoBinder and MTA (30 and 90 days), these percentage values were statistically higher than those of the control group (P < .05); however, they were similar to those of calcium hydroxide (P > .05). Conclusions EndoBinder and MTA allowed complete repair of bone defects created in rat tibias.