138 resultados para Plastic Antibodies
Resumo:
Leaks in pipes are a common issue encountered in the water industry. Acoustic methods are generally successful in finding and locating leaks in metallic pipes, however, they are less effective when applied to plastic pipes. This is because leak-noise signals are heavily attenuated due to high damping in the pipe-wall and sound radiation into the soil. As result, high frequency leak noise does not travel long distances. To determine how far leak noise may travel in a pipe at any frequency, the attenuation of the wave responsible for leak noise propagation should be known. In this paper a new method to estimate this is described. The method is then applied to some measurements made on a bespoke pipe-test rig in the UK, and the results are compared with theoretical predictions.
Resumo:
The vaccinal antibodies interference represents one of the problems in the leptospirosis diagnostic on serum. The present study aimed to determine the pattern of serum agglutinins anti-Leptospirae spp in vaccinated female buffaloes against leptospirosis using two types of commercial vaccines: bacterin and extern membrane. The temporal interference of vaccinal titers on serum diagnostic was evaluated. Three groups of 11 adult female buffaloes were established as follows: G1 control, non-vaccinated; G2: vaccinated with bacterin containing six serovars and G3 with extern membrane vaccine containing five serovars. A booster was administered at 30 days from the first vaccination (dfv) and two re- vaccinations were performed in each semester (days 210 and 390). Serum samples were collected on days 0, 15, 30, 45 and 60 and every 30 days until 540 dfv, being submitted to Serum Agglutination Microscopy (SAM) against the serovars present in the vaccine. G1 remained always negative. Both vaccines induced serologic responses when assessed by SAM at 150 days post first vaccination against all serovars and they revealed maximum titers around days 45 and 60 after first vaccination. At the re-vaccination there was an increase on agglutinin levels, but of less intensity than the levels previously observed. After six months from the second revaccination (540 dfv), they were almost zero, which demonstrates the short duration of diagnostic interference. The serologic monitoring of the vaccinated herds can be an efficient method to evaluate the status of protection provided by the vaccine.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Acoustic techniques have been used for many years to find and locate leaks in buried water distribution systems. Hydrophones and accelerometers are typically used as sensors. Although geophones could be used as well, they are not generally used for leak detection. A simple acoustic model of the pipe and the sensors has been proposed previously by some of the authors of this paper, and their model was used to explain some of the features observed in measurements. However, simultaneous measurements of a leak using all three sensor-types in controlled conditions for plastic pipes has not been reported to-date and hence they have not yet been compared directly. This paper fills that gap in knowledge. A set of measurements was made on a bespoke buried plastic water distribution pipe test rig to validate the previously reported analytical model. There is qualitative agreement between the experimental results and the model predictions in terms of the differing filtering properties of the pipe-sensor systems. A quality measure for the data is also presented, which is the ratio of the bandwidth over which the analysis is carried out divided by the centre frequency of this bandwidth. Based on this metric, the accelerometer was found to be the best sensor to use for the test rig described in this paper. However, for a system in which the distance between the sensors is large or the attenuation factor of the system is high, then it would be advantageous to use hydrophones, even though they are invasive sensors.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
The establishment of laboratory colonies of ticks is often hampered by their lack of adaptation to alternative hosts. The aim of this study was to artificially feed partially engorged Dermacentor (Anocentor) nitens females through plastic tips, and to identify what are the optimal conditions of application of this technique to get as much as possible close to the natural conditions. The technique of artificial feeding through plastic tips allowed the engorgement of D. nitens ticks to a final weight within the normal range for the species. (C) 2014 Published by Elsevier GmbH.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Mesenchymal stem cells (MSCs) are a heterogeneous population of cells that proliferate in vitro as plastic-adherent cells, have fibroblast-like morphology and can differentiate into bone, cartilage and fat cells. Therapeutic potential of MSCs have been studied in experimental models, such as rabbit, in Laboratory of Cell Engineering of Botucatu. However, no specific markers have been reported for expanded rabbit MSCs, which hampers the isolation of pure MSC populations by immunophenotypic characterization. Thus, the objective of this study was to produce monoclonal antibodies (mAbs) to rabbit MSCs. MSCs derived from rabbit bone marrow (BM) were isolated, cultured, expanded ex vivo, and immunized into three BALB/c mices, and spleen cells subsequently harvested were used to generate hibridoma cell lines secreting antibodies against MSCs. Hybridoma cells were screened by flow cytometry and antibody-producing cells were subjected to subsequent rounds of retests. MSC1-160 obtained the best positivity for IgG expression and was cloned by limiting dilutions and micromanipulation. Ascitic fluid from ten best clones was purified by affinity chromatography in Protein A-sepharose CL-4B column and purification control was performed by electrophoresis in agarose gels. The purified IgG were tested against rabbit MSCs, obtaining high positivity by flow Cytometry. In conclusion, we developed 10 mAbs, MSC1-160 A20, A30, A41, A47, A55, A60, A63, A69, A81, and A82, that recognize rabbit MSC cell surface antigens showing potential for immunophenotypic characterization of rabbit MSC cell lines
Resumo:
Mesenchymal stem cells (MSCs) are adult multipotent cells with fibroblastoid morphology and adherent to plastic. Furthermore, they can be obtained from different sources. Besides bone marrow, these cells are taken from umbilical cord blood, umbilical vein, saphenous vein, peripheral blood, arteries, liver and fetal pancreas, placenta, dental pulp and adipose tissue. MSCs derived from adipose tissue are important because of the abundant number of cells that can be obtained from this tissue, easy access and little discomfort to the patient. This study compared two techniques for obtaining MSCs from adipose tissue: mechanical dissociation (MD) and enzymatic digestion (ED). We also analyzed the inter-species cross-reactions using commercial monoclonal antibodies directed against surface antigens of stem cells from different species: mouse, horse, rabbit, monkey and human. We found that MD technique is favorable in relation to ED within 15 days of culture, and ED is more efficient in the first days of culture. The data also showed that MD causes less damage to cellular DNA. About inter-species cross-reactions, the monoclonal antibody A69 directed against stem cells from rabbits, which can be used in veterinary medicine, particularly in research involving horses
Resumo:
Neosporosis is an emergent disease responsible for considerable economic impact due to reproductive losses. Its zoonotic potential remains unknown. This study involved a survey of antibodies to Neospora caninum in slaughtered sheep and their association with epidemiological variables. Serum samples from 596 sheep from the states of Sao Paulo and Rio Grande do Sul, Brazil, were collected in two slaughterhouses located in Sao Paulo and evaluated by indirect fluorescence antibody test (IFAT), using cut-off titers of 25. Among these samples, 353/596 (59.23%; 95%CI 55.23-63.10) were positive and 263/353 (74.50%; 95%CI 69.71-78.77%) were from Rio Grande do Sul. Statistical associations were determined in the univariate analysis between the serological results and sex, breed and municipality of origin. Sheep that came from extensive breeding system showed higher chance (OR=2.09) of presenting antibodies to N. caninum in relation to those from semi-intensive system. Higher chance was also observed for the different studied breeds, except Bergamacia, in relation to Hampshire Down. The results revealed the presence of infection by N. caninum in sheep from slaughterhouses.
Resumo:
The aim of this in vitro study was to use strain gauge (SG) analysis to compare the effects of the implant-abutment joint, the coping, and the location of load on strain distribution in the bone around implants supporting 3-unit fixed partial prostheses. Three external hexagon (EH) implants and 3 internal hexagon (IH) implants were inserted into 2 polyurethane blocks. Microunit abutments were screwed onto their respective implant groups. Machined cobalt-chromium copings and plastic copings were screwed onto the abutments, which received standard wax patterns. The wax patterns were cast in a cobalt-chromium alloy (n = 5): group 1 = EH/machined. group 2 = EH/plastic, group 3 = IH/machined, and group 4 = IH/plastic. Four SGs were bonded onto the surface of the block tangentially to the implants. Each metallic structure was screwed onto the abutments and an axial load of 30 kg was applied at 5 predetermined points. The magnitude of microstrain on each SG was recorded in units of microstrain (mu epsilon). The data were analyzed using 3-factor repeated measures analysis of variance and a Tukey test (alpha = 0.05). The results showed statistically significant differences for the type of implant-abutment joint, loading point, and interaction at the implant-abutment joint/loading point. The IH connection showed higher microstrain values than the EH connection. It was concluded that the type of coping did not interfere in the magnitude of microstrain, but the implant/abutment joint and axial loading location influenced this magnitude.
Resumo:
Toxoplasmosis and neosporosis have been recognized as economically important diseases with considerable impact on the livestock industry. Little is known concerning the occurrence of Toxoplasma gondii and Neospora caninum in sheep from Tocantins state, Brazil. Here, we investigated antibodies against these parasites and associated factors in 182 sheep from Araguaina, Santa Terezinha do Tocantins, Arguianopolis and Palmeiras do Tocantins districts, Tocantins. Sheep sera were assayed for T. gondii and N. caninum IgG antibodies by indirect fluorescence antibody test (IFAT), using cut-off point at a dilution of 1: 40 and 1: 25 respectively. The prevalence of seropositive animal for T. gondii was 13.74% and 13.74% for N. caninum. None of the characteristics studied including reproductive problems, presence of cats, presence of dogs and veterinary care (p>0.05) was associated with occurrence of T. gondii or N. caninum infection. Only breed was identified as associated factor for the occurrence of toxoplasmosis in sheep (p<0.05). The present study is the first report on serum occurrence of T. gondii and N. caninum in sheep from the state of Tocantins, Brazil.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
In water distribution systems, old metallic pipes have been replaced by plastic pipes due to their deterioration over time. Although acoustic methods are effective in finding leaks in metallic pipes, they have been found to be problematic when applied to plastic pipes due to the high damping within the pipe wall and the surrounding medium. This is responsible for the leak signal not traveling long distances. Moreover, the leak energy in plastic pipes is generally located at a narrow frequency range located at low frequencies. However, the presence of resonances can narrow even more this frequency range. In order to minimise the influence of background noise and resonances on the calculation of the time delay estimate, band-pass filters are often used to supress undesirable frequency components of the noise. The objective of this paper is to investigate the influence of resonances in the pipe system (pipe, valves, connections and hydrants), on the time delay estimate calculated using acoustic signals. Analytical models and actual leak data collected in a bespoke rig located in the United Kingdom are used to investigate this feature.
Resumo:
An available enzyme-linked immunosorbent assay (ELISA) was studied for the detection of anti-Dioctophyma renale antibodies in the sera of dogs using, detection of parasite eggs in urine sediment as a reference test. ELISA uses a soluble antigenic preparation of esophagus of D. renale and the optimal dilutions of the antigen, serum and conjugate were determined by means of checker board titration, using positive (n=13) and negative (n=27) reference serum. The specificity and sensitivity of the ELISA were 93.8% and 92.3% respectively and the kappa index was good (0.76). These results suggest that ELISA described may prove to be an effective serological test for detecting dogs infected and exposed to this parasite mainly dogs that are not eliminating parasite eggs through their urine.