135 resultados para Piezoelectric vibration
Resumo:
The aim of this study was to evaluate the morphology and adhesion of blood components on root surfaces instrumented with piezoelectric ultrasonic Piezon Master Surgery. Methods 10 teeth were used in this study. The teeth had their proximal divided into four areas that received different treatments: Group 1: untreated control Group 2: scaling with manual instrument; Group 3: scaling with ultrasound; Group 4: Scaling with manual instruments and ultrasound. We obtained 20 samples, 10 of which were used to analyze the morphology and the other 10 were used for analysis of adhesion of blood components. The specimens were analyzed by scanning electron microscopy. Photomicrographs were analyzed by the scores of adhesion of blood components and the index of root morphology. The results were statistically by the Kruskall-Wallis and Mann-Whitney with a significance level of 95%. Results The morphological analysis showed that the Group 1 had a surface unchanged in relation to other groups (Group 1 X Group 2 = 0.0025; Group 1 X Group 3 = 0.0003; Group 1 X Group 4 = 0.0003) and Group 2 presented a smoother surface compared to Group 1 and groups instrumented with ultrasound (Group 2 X Group 3 = 0.0025; Group 2 X Group 4 = 0.0025) there were no statistical differences between the Groups 3 and 4. analysis of adhesion of blood components showed that the Groups 2, 3 and 4 had no statistically significant differences between themselves, but more biocompatible surfaces promoted the surface untreated control (Group 1 X Group 2 = 0.02; Group 1 X Group 3 = 0.04; Group 1 X Group 4 = 0.005). Conclusion The instrumentation with piezoelectric ultrasonic promoted an irregular root surface, but did not negatively affect the adhesion of blood components.
Resumo:
To evaluate the influence of variations in the working angle of the piezoelectric ultrasonic scaler (PUS) on root surfaces. Material and methods Fifty-five uniradicular bovine teeth were used, of which 25 teeth were used for the analysis of the roughness and root wear, while the remaining 30 teeth were used for the analysis of morphology (MRS) and the attachment of blood components (ABC). The teeth were randomly divided into five groups according to the type of treatment (G1-G5: piezoelectric ultrasonic scaler; G6: manual curette) and to the PUS working angle applied (G1: 0°; G2: 30°; G3: 45°; G4: 60°; G5: 90°). For statistical analysis, the data describing the MRS and ABC were analysed by the Kruskal–Wallis and Dunn's tests, and the data describing the roughness and tooth wear were analysed by anova and Tukey's tests at the significance level of 5%. Results Manual curette (MC) promoted a smoother root surface than the application of the PUS. The PUS used at the angles of 30° and 45° resulted in a high level of ABC that was comparable to that obtained by MC. Additionally, the group in which the PUS was applied at an angle of 45° exhibited less tooth wear than the other groups. Conclusions Changes in the working angle of the PUS influenced the characteristics of root surfaces after instrumentation.
Resumo:
Pós-graduação em Engenharia Mecânica - FEIS
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Synthetic-heterodyne demodulation is a useful technique for dynamic displacement and velocity detection in interferometric sensors, as it can provide an output signal that is immune to interferometric drift. With the advent of cost-effective, high-speed real-time signal-processing systems and software, processing of the complex signals encountered in interferometry has become more feasible. In synthetic heterodyne, to obtain the actual dynamic displacement or vibration of the object under test requires knowledge of the interferometer visibility and also the argument of two Bessel functions. In this paper, a method is described for determining the former and setting the Bessel function argument to a set value, which ensures maximum sensitivity. Conventional synthetic-heterodyne demodulation requires the use of two in-phase local oscillators; however, the relative phase of these oscillators relative to the interferometric signal is unknown. It is shown that, by using two additional quadrature local oscillators, a demodulated signal can be obtained that is independent of this phase difference. The experimental interferometer is aMichelson configuration using a visible single-mode laser, whose current is sinusoidally modulated at a frequency of 20 kHz. The detected interferometer output is acquired using a 250 kHz analog-to-digital converter and processed in real time. The system is used to measure the displacement sensitivity frequency response and linearity of a piezoelectric mirror shifter over a range of 500 Hz to 10 kHz. The experimental results show good agreement with two data-obtained independent techniques: the signal coincidence and denominated n-commuted Pernick method.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
An excitation force that is not influenced by the system's states is said to be an ideal energy source. In real situations, a direct and feedback coupling between the excitation source and the system must always exist. This manifestation of the law of conversation of energy is known as Sommerfeld Effect. In the case of obtaining a mathematical model for such system, additional equations are usually necessary to describe the vibration sources and their coupling with the mechanical system. In this work, a cantilever beam and a non-ideal electric DC motor that is fixed to the beam free end is analyzed. The motor has an unbalanced mass that provides excitation to the system proportional to the current applied to the motor. During the motor's coast up operation, as the excitation frequency gets closer to the beam first natural frequency and if the drive power increases further, the DC motor speed remains constant until it suddenly jumps to a much higher value (simultaneously the vibration amplitude jumps to a much lower value) upon exceeding a critical input power. It was found that the Sommerfeld effect depends on some system parameters and the motor operational procedures. These parameters are explored to avoid the resonance capture in Sommerfeld effect. Numerical simulations and experimental tests are used to help insight this dynamic behavior.
Resumo:
In this work, nanometric displacement amplitudes of a Piezoelectric Flextensional Actuator (PFA) designed using the topology optimization technique and operating in its linear range are measured by using a homodyne Michelson interferometer. A new improved version of the J1...J4 method for optical phase measurements, named J1...J5 method, is presented, which is of easier implementation than the original one. This is a passive phase detection scheme, unaffected by signal fading, source instabilities and changes in visibility. Experimental results using this improvement were compared with those obtained by using the J1... J4, J1...J6(pos) and J1...J 6(neg) methods, concluding that the dynamic range is increased while maintaining the sensitivity. Analysis based on the 1/f voltage noise and random fading show the new method is more stable to phase drift than all those methods. © 2012 IEEE.
Resumo:
Piezoelectric transducers are widely used in high-resolution positioning systems. This paper reports the experimental analysis of a novel piezoelectric flextensional actuator (PFA), which is designed by using the topology-optimization method through a low-cost homodyne Michelson interferometer. By applying the J(1) - J(4) method for signal demodulation, which provides a linear and direct measurement of dynamic optical phase shift independent of fading, the nanometric displacements of the PFA were determined. Linearity and frequency response of the PFA were evaluated up to 50 kHz. PFA calibration factor and amplification rate were determined for the PFA operating in the quasi-static regime. To confirm the observed frequencies of resonance, an impedance analyzer is also utilized to measure the magnitude and phase of the PFA admittance.
Resumo:
In maxillary Le Fort I type osteotomy the detachment of the nasal mucosa should be done carefully. Piezoelectric surgery contributed much to increase the safety of osteotomies, despite the initial advantage of minimizing the risk of injury in nervous tissue, mainly in bilateral sagittal split osteotomy; we use the piezoelectric device for the initial detachment of the nasal mucosa in the maxillary osteotomy.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Pós-graduação em Engenharia Mecânica - FEB
Resumo:
The aim of this study was to evaluate the production of eggplant fruit according to plant vibration in two types of protected environments, with and without an aphid-proof screen, preventing or permitting the entry of pollinators. Two eggplant hybrids (Roxelle, clear purple color and round shape fruits, and Kokushi, purple color and elongated fruits), two vibration treatments (with or without plant vibration), and two environments (with or without screen) were assessed. It was concluded that the presence of insects in the open environment increases marketable fruit yield only in hybrid Roxelle (2120 and 1172 g plant-1, with and without insects, respectivelly), the number of seeds per fruit in both hybrids in treatment without plant vibration (average of 584 and 110 seeds, with and without insects, respectivelly), and that plant vibration may partially replace the absence of pollinator insects in a closed environment protected with a screen, with an increase in fruit yield.