185 resultados para Pelvic Floor Ultrasound


Relevância:

20.00% 20.00%

Publicador:

Resumo:

In the present paper, it was investigated the aspect of the intrapelvic autonomic neuronal system (juxtaprostatic ganglion) and gonads of rats submitted to a experimental alcoholism. The animals which had water substituted for 35% sugar cane spirit for 30 d, presented testicular lesions as well as numeric and degenerative alterations in the juxtaprostatic pelvic ganglia neurons.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The work consists of the study of 20 opossums (Didelphis albiventris); 7 females and 13 males, adults, natives of Jaboticabal county proceeding to a canulation and injection of the arterial system with neoprene latex-650 in the aorta artery (full-blooded). Right away the preparations were fixed by a 10% formaldehyde aqueous solution and afterwards dissected and formed a scheme. The analysis of the pieces showed that in the opossum, the end of the aorta always divides in the common iliac artery, right and left sides, both originating the external and internal iliac artery, on the right and left sides. The medium sacral artery results, medianly, from the aorta division's angle in 2 common iliac arteries in 8 cases (40% - 6 males and 2 females); this vessel comes from the left common iliac artery in 7 animals (35% - 5 males and 2 females) or comes from the right common iliac artery, in 5 preparations (25% - 3 females and 2 males). The deep iliac circumflex artery is born by the common iliac artery from the right side in 10 preparations (50% - 6 males and 4 females), can appear as well, concomitantly with the external and internal iliac artery, from the right side in 9 pieces (45% - 6 males and 3 females) and further from the right this vessels can emerge from the external iliac artery, in 1 case only (5% - 1 male).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The acid catalyzed and ultrasound stimulated hydrolysis of solventless tetraethoxysilane-water mixtures was studied at 39°C as a function of HCl added to the mixtures (log[HCl]-1 ranged from 0.8 to 2.0), The reaction was carried out in a specially designed device, in which a steady state heat flow is maintained, while sonication is taking place, if no reaction is expected to occur. The exothermal hydrolysis reaction causes an increasing temperature (ΔTt) as a function of the reaction time, t. The isothermal hydrolysis rate constant, k, has been evaluated from the experimental ΔTt versus t data, after corrections for the increasing temperature effects, by using a method resulting from our theoretical modeling based on a dissolution and reaction mechanism. The hydrolysis rate constant fits closely a k α [H+] law as expected for this kind of hydrogen-ion catalyzed reaction.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Temporal and spatial acoustic intensity (SATA) of therapeutic ultrasound (US) equipment should be monitored periodically. In order to evaluate the conditions of US equipment in use in the city of Piracicaba-Sao Paulo, Brazil, 31 machines - representing all Brazilian manufacturers - were analysed under continuous and pulsed conditions at a frequency of 1 MHz. Data about temporal and spatial acoustic intensity were collected and the use of equipment was surveyed. Intensities of 0.1, 0.2, 0.5, 0.8, 1.0, 1.5, 2.0, 2.5 and 3.0 Wcm -2, indicated on the equipment panel were analysed using a previously calibrated digital radiation pressure scale, model UPM-DT-1 (Ohmic Instruments Co). The acoustic intensity (I) results were expressed as superior and inferior quartile ranges for transducers with metal surfaces of 9 cm 2 and an effective radiation area (ERA) Of 4 cm 2. The results under continuous conditions were: I 0.1 = -20.0% and -96%. I 0.2 = -3.1% and -83.7%. I 0.5 = -35.0% and -86.5%. I 0.8 = -37.5% and -71.0%. I 2.5 = -49.0% and -69.5%. I 3.0 = -58.1% and -77.6%. For pulsed conditions, intensities were: I 0.1 = -40.0% and -86.2%. I 1.0 = -50.0% and -86.5%. I 1.5 = -62.5% and -82.5%. I 2.0 = -62.5% and -81.6%. I 2.5 = -64.7% and -88.8%. I 3.0 = -87.1% and -94.8%. In reply to the questionnaire drawn up to check the conditions of use of equipment, all users reported the use of hydrosoluble gel as a coupling medium and none had carried out previous calibrations. Most users used intensities in the range of 0.4. to 1.0 Wcm -2 and used machines for 300 to 400 minutes per week. The majority of machines had been bought during the previous seven years and weekly use ranged from less than 100 minutes to 700 minutes (11 hours 40 minutes). Findings confirm previous observations of discrepancy between the intensity indicated on the equipment panel and that emitted by the transducer and highlight the necessity for periodic evaluations of US equipment.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Structural changes induced by ultrasound during the aging of the aluminum monohydroxide (boehmite) were studied by means of X-ray diffraction (XRD) and nitrogen adsorption. The BET surface area and the pore volume of the ultrasound stimulated hydroxide (HU) are about 40% less than those of the non-stimulated one (HS). The mean pore size practically does not change, while the mean crystallite size (L) is about 25% greater in the HU system. The increase of L alone is not enough to account for the surface area diminution, suggesting that the sonication also induces compaction by elimination of some porosity. The sonication of the precursor hydroxide does not seem to play an apparent role in the structural properties of the resulting calcinated γ-alumina. © 1997 Elsevier Science B.V.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Diphasic gel in the mullite composition was prepared from a colloidal sol of boehmite mixed with a hydrolyzed tetraethoxisilane (TEOS) solution. The boehmite sol was obtained by peptization of a poorly crystallized or very small mean crystallite size (∼34 Å) precipitate, resulting from the reaction between solutions of aluminum sulfate and sodium hydroxide. Ultrasound was utilized in the processes of the TEOS hydrolysis and the boehmite peptization, and also for complete homogenization of the mixture to gel. The wet gel is almost clear and monolithic. The gel transparency is lost on drying, when syneresis has ended, so that the interlinked pore structure starts to empty and is recovered upon water re-absorption. Cracking closely accompanies this critical drying process. Differential thermal analysis (DTA) and X-ray diffraction (XRD) show that the solid structure of the gel is composed of an amorphous silica phase, as a matrix, and a colloidal sized crystalline phase of boehmite. Upon heat treatment, the boehmite phase within the gel closely follows the same transition sequence as in pure alumina shifted towards higher temperatures. Orthorhombic mullite formation was detected at 1300°C. © 1998 Elsevier Science B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objective of this study was to investigate the effects of ultrasound treatment and physical exercise on the velocity of bone consolidation and resistance to deformation. We performed osteotomy in the upper third of the right tibia of rats. Physical training consisted of swimming 1 h per day with a load of 5% b.w. for 30 days. Therapy with medium-intensity ultrasound was applied daily on the damaged area. Wistar rats were divided into the following groups: osteotomized sedentary animals with no ultrasound treatment (1.OSnUS), osteotomized trained animals with no ultrasound treatment (2.OTnUS), osteotomized sedentary animals with ultrasound treatment (3.OSwUS). and osteotomized trained animals with ultrasound treatment (4.OTwUS). The animals were sacrificed for the following analyses: muscle glycogen, serum alkaline phosphatase at the 5th, 10th, 20th, and 30th days, test of maximum resistance to flexion, rupture flexion and mean tibial rigidity at the 30th day. Muscle glycogen was increased at the 20th day: alkaline phosphatase was elevated at the 5th and 20th days in groups 3.OSwUS and 4.OTwUS. and decreased at the 10th day. Groups1.OSnUS and 2.OTnUS did not show significant variations. In the mechanical resistance tests, we noted that ultrasound therapy and the association of physical activity used in the present study showed significant differences in bone resistance and bone rigidity after 30 days of treatment. These facts suggest that ultrasound or physical activity, or their combination may accelerate the process of bone tissue repair.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aim: The aim of this study was to evaluate the influence of ultrasound during the removal of posts cemented with either zinc phosphate cement, glass ionomer cement or resin cement. Methodology: Eighty-four single-rooted teeth were prepared and after cementation of cast posts, they were randomly divided into six groups of 14. Groups 1, 2 and 3 did not receive ultrasonic vibration, whilst groups 4, 5 and 6 received ultrasonic vibration for 10 min. The force necessary for post removal was determined using a universal testing machine. Results were statistically analysed using ANOVA and Tukey tests (5%). Results: The application of ultrasonic vibration reduced the retention provided by zinc phosphate and glass ionomer cements by 39% and 33%, respectively. Conclusions: A statistically significant reduction in the force necessary to remove posts cemented with zinc phosphate and glass ionomer cements occurred following application of ultrasound. The application of ultrasonic vibration did not influence the retention of cast posts cemented with resin cement.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents an ultrasonic method to measure small concentrations of water in lubricating oil. It uses an ultrasonic measurement cell composed by a piezoceramic emitter (5 and 10 MHz), and a large aperture PVDF receiver that eliminates diffraction effects. The propagation velocity, attenuation coefficient and density of several samples of water-in-oil emulsion were measured. The concentrations of water of the samples were in the range of 0 to 5% in volume, and the results showed that these low concentrations can be discriminated within a resolution of 0.2% in the studied range, using the measurement of the propagation velocity.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The urethra is the main place of entry for sexually transmitted pathogens. However, there is little literature on the morphology of the urogenital system, principally the urethra and ducts of the sex accessory glands. The Mongolian gerbil is an insectivorous, herbivorous and monogamous rodent with nocturnal habits; it has been used successfully as a laboratory animal since the 1960s. Therefore, the objective of the present paper was to describe the structure and ultrastructure of the urethra and its relations to the ducts of the accessory sex glands of the Mongolian gerbil (Meriones unguiculatus), contributing to the understanding of the reproductive biology of the rodent and aiming to provide data for future experimental studies. Conventional techniques of light and scanning electron microscopy were utilized. The urethra and ducts of the accessory sex glands are similar to those of the albino rat and the mouse. However, there is variation in drainage type among accessory sex glands for the inner urethra. The ducts of the seminal vesicle, the ductus deferens, drain their contents independently into the ampullary duct that opens in the urethra. The ducts of the prostate, coagulating and bulbourethral glands drain their contents independently into the urethra.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The effects of low-intensity pulsed ultrasound on wound healing were evaluated at the graft-cornea transition in dogs following lamellar keratoplasty using tunica vaginalis preserved in 98% glycerin. Twenty-one dogs were subdivided into three groups of seven animals. The first group (W/US) received daily treatment of low-intensity pulsed ultrasound (20 mW/cm 2) for 15 min for the first 10 days post surgery. The second group (N/US) was submitted to the same procedure but with the ultrasound apparatus turned off. The third group, the control (CO), underwent the surgical procedure only. The animals were clinically evaluated during the initial (1-15 days), intermediate (16-30 days) and late (31-120 days) postoperative period. The corneas were evaluated by light microscopy at 1, 3, 7, 15, 30, 60 and 120 days after surgery. Clinically, there were no differences which would promote an advantage to any of the treatments. Light microscopy, however, revealed more extensive vascularization and more advanced wound healing in the W/US group, as well as a tendency towards early graft incorporation. Based on the present results, low-intensity pulsed ultrasound shows advantages, especially in situations where trophic support is a mandatory condition, facilitating better graft incorporation and rapid recovery of stromal organization.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

It is usual to find athletes that can perform de curl up test easily, but are unable to maintain the stabilization of the low back during the double straight leg lowering (DSLL). In spite of having strong abdominal muscles, its stabilization role seems not to be effective. Thus, the purpose of this study was to verify the relation among individuals with strong abdominal muscles and the ability in perform posterior pelvic tilt (PPT); the ability to stabilize the low back during the DSLL and the eletromyographic activity of the abdominal muscles. Eighteen male subjects (aged 19.27 ± 3.5), without history of muscle skeletal dysfunction, performed both the PPT and DSLL tests. During these tests electromyographic signals of the rectus abdominis (RA), obliquus internus abdominis (01) and obliquus externus abdominis (OE) were recorded, the angle of the hip and the pressure under the low back were measured The results of analyses of variance (ANOVA) show that most volunteers accomplished the PPT test, actively flattening the low back with regular or good quality. However, none of them was able to stabilize the low back during the DSLL test. During the PPT test all abdominal muscle portions analysed were activated without significant differences. In an attempt of maintaining the lumbo-pelvic region stabilized during the DSLL, it was observed a tendency of higher bilateral activation of OE when compared to RA and 01 muscle portions between 70 and 20 degrees of hip flexion.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We often face Patients searching for rehabilitation for lower back disorders during the physiotherapeutic routine, and it is known that the abdominal muscle, specially the rectus abdominis muscle, aid the stabilization of the pelvis. Therefore, this paper analyzes the electrical activity of the rectus abdominis muscle in the pelvic retroversion in dorsal decubitus and in orthostatic position and in the lowering of the lower limbs. 30 healthy students, male and female, 17-40 yr, divided into two groups - Group 1: 15 volunteers (pelvic balance); Group 2 (pelvic unbalance) took part in this study. The electrical activity of the right and left supra-umbilical and infra-umbilical portions of the rectus abdominis muscle was detected. The mean RMS values from three attempts ftom the electromyographic traces were usedfor the analysis of the electrical activity. The RMS value was submitted to the normalization process. The data were submitted to statistic treatment by the Friedman test, and the analyses of the means and standard deviation towards a level of significance of 95%. The results demonstrated that the portions of the rectus abdominis muscle presented low electrical activity for the groups studiedfor pelvic retroversion either in dorsal decubitus or and orthostatic position. However, the decreasing movement of the lower limbs towards the portions of the rectus abdominis muscle presented more significant electrical activity whereas the lower portions presented higher activity than the higher ones for Group 2.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A previous work showed that viscosity values measured high frequency by ultrasound agreed with the values at low frequency by the rotational viscometer when conditions are met, such as relatively low frequency viscosity. However, these conditions strongly reduce the range of the measurement cell. In order to obtain a measurement range and sensitivity high frequency must used, but it causes a frequency-dependent decrease on the viscosity values. This work introduces a new simple in order to represent this frequency-dependent behavior.model is based on the Maxwell model for viscoelastic , but using a variable parameter. This parameter has physical meaning because it represents the linear behavior the apparent elasticity measured along with the viscosity by .Automotive oils SAE 90 and SAE 250 at 22.5±0.5oC viscosities at low frequency of 0.6 and 6.7 Pa.s, respectively,tested in the range of 1-5 MHz. The model was used in to fit the obtained data using an algorithm of non-linear in Matlab. By including the viscosity at low frequency an unknown fitting parameter, it is possible to extrapolate its . Relative deviations between the values measured by the and extrapolated using the model for the SAE 90 and SAE 250 oils were 5.0% and 15.7%, respectively.©2008 IEEE.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper proposes a method to determine iron in samples of fish feed and feces using ultrasound in the extraction of the analyte and in subsequent quantification by flame atomic absorption spectrometry. Using HCl 0.10 mol L -1 as the extraction solution, the optimal conditions of extraction were found to be: granulometry of the sample <60 μm; a sonication time of five cycles of 10 s and sonication power of 136 W. The method was applied in studies of the availability of iron in four food sources used in the diet of Nile Tilapia. The results obtained with the proposed extraction method allowed us to calculate the coefficients of apparent digestibility of iron in the food sources, which was not possible when using results obtained from samples mineralized by acid digestion. © Springer Science+Business Media, LLC 2008.