401 resultados para Lingual appliance


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background: There is some evidence showing that cyclosporin A (CsA) and nifedipine (NIF) affect bone metabolism. The purpose of this work was to study the effects of CsA and NIF, given alone or concurrently, on alveolar bone of rats of different ages. Methods: Rats 15, 30, 60, and 90 days old were treated daily with 10 mg/kg body weight of CsA subcutaneously injected and/or 50 mg/kg body weight of NIF/day given orally for 60 days. Alveolar bone of the first lower molars was morphologically and stereologically evaluated in serial 5 μm bucco-lingual paraffin sections, stained with hematoxylin and eosin. Serum calcium and alkaline phosphatase levels were measured in all animals at the end of the experimental period. Results: Rats treated with CsA or NIF alone or CsA and NIF concurrently showed decreased alveolar bone density. CsA was more effective than NIF. A significant decrease in serum calcium was found only in animals treated with CsA or CsA/NIF. The results were similar regardless of age. Conclusions: These results indicate that the decrease in the alveolar bone volume in rats caused by CsA and NIF alone or concurrently is not age dependent. Furthermore, NIF (50 mg/kg) did not further increase the loss of alveolar bone volume induced by CsA (10 mg/kg).

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The purpose of our investigation is to compare the intrapulpal temperature changes following blue LED system and halogen lamp irradiation at the enamel surface of permanent teeth. The fixation of brackets using composite resin is more comfortable and faster when using a photo-curable composite. Several light sources can be used: halogens, arc plasma, lasers, and recently blue LED systems. An important aspect to be observed during such a procedures is the temperature change. In this study, we have used nine human extracted permanent teeth: three central incisors, three lateral incisors, and three canines. Teeth were exposed to two light sources: blue LED system (preliminary commercial model LEC 470-II) and halogen lamp (conventional photo-cure equipment). The surface of teeth was exposed for 20, 40, and 60 sec at the buccal and lingual enamel surface with an angle of 45 degrees. Temperature values measured by a thermistor placed at pulpar chamber were read in time intervals of 1 sec. We obtained plots showing the temperature evolution as a function of time for each experiment. There is a correlation between heating quantity and exposition time of light source: with increasing exposition time, heating increases into the pulpal chamber. The halogen lamp showed higher heating than the LED system, which showed a shorter time of cooling than halogen lamp. The blue LED system seems like the indicated light source for photo-cure of composite resin during the bonding of brackets. The fixation of brackets using composite resin is more comfortable and faster when using a photo-curable composite. Blue LED equipment did not heat during its use. This could permit a shorter clinical time of operation and better performance. © Mary Ann Liebert, Inc.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background: Patients with fixed orthodontic appliances often experience an absolute increase in the number of Streptococci mutans colony-forming units (cfu). The aim of this investigation was to study the development of biofilm and S. mutans cfu in connection with stainless steel ligatures and elastomeric rings in orthodontic patients treated with and without 0.4% stannous fluoride gel (SFG). Material: Forty-seven patients were divided into 2 groups: those treated with 0.4% SFG for 4 minutes (experimental) and those without 0.4% SFG (control). In each patient, elastomeric rings were used for ligation on 1 side of the dental arch midline, and stainless steel ligatures were used on the opposite side. Saliva samples were collected before and after appliance placement. At 15 and 30 days after appliance placement, biofilm samples from the stainless steel ligatures and the elastomeric rings were collected and subjected to microbiologic procedures and scanning electron microscopy (SEM) analysis. Results: The numbers of S. mutans cfu in the saliva and biofilm were not statistically different between the teeth fitted with elastomeric rings and stainless steel ligatures, or between the experimental and control groups. SEM analysis showed biofilm formation on both ligature ties. Conclusions: Topical application of 0.4% SFG in orthodontic patients with elastomeric rings or stainless steel ligatures does not cause a significant decrease in S. mutans cfu in the saliva and biofilm. Copyright © 2005 by the American Association of Orthodontists.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: This study tested the null hypothesis that different treatments of saliva-contaminated substrate would not affect microgap formation at the dentin walls of bonded restorations. Materials and Methods: Forty freshly extracted human molars received standardized Class V preparations on buccal and lingual surfaces. The specimens were assigned to four experimental groups (n = 20): [G1] no contamination (control group), [G2] saliva contamination (10 s) after etching followed by 5 s air stream; [G3] saliva contamination after etching and rinsed for 10 s; and [G4] re-etching for 10 s after saliva contamination. All specimens were restored with a one-bottle adhesive (Single Bond, 3M ESPE) and microhybrid composite resin (Filtek Z250, 3M ESPE) according to the manufacturer's instructions. The specimens were thermocycled, sectioned through the center of the restoration, and then processed for SEM. Microgaps were measured at the axial wall at 1500X magnification. The data were submitted to Kruskal-Wallis nonparametric statistical analysis at p < 0.05. Results: The data revealed that different groups resulted in a statistically significant difference (p < 0.01) in gap formation. Air drying [G2] and rinsing [G3] the saliva-contaminated dentin resulted in similar microgap values (p > 0.05). However, re-etching the dentin after saliva contamination [G4] increased microgap formation (p < 0.05) when compared with the groups G1 and G2. Although air drying and rinsing produced results comparable to noncontaminated dentin, the presence of microgaps was not completely eliminated. Conclusion: Contaminated saliva did not prevent hybrid layer formation; however, it did reduce the adaptation of the restorative material to bonded surfaces.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: The aim of this study was to evaluate the interfacial microgap with different materials used for pulp protection. The null hypothesis tested was that the combination of calcium hydroxide, resin-modified glass ionomer, and dentin adhesive used as pulp protection in composite restorations would not result in a greater axial gap than that obtained with hybridization only. Materials and Methods: Standardized Class V preparations were performed in buccal and lingual surfaces of 60 caries-free, extracted human third molars. The prepared teeth were randomly assessed in six groups: (1) Single Bond (SB) (3M ESPE, St. Paul, MN, USA); (2) Life (LF) (Kerr Co., Romulus, MI, USA) + SB; (3) LF + Vitrebond (VT) (3M ESPE) + SB; (4) VT + SB; (5) SB + VT; (6) SB + VT + SB. They were restored with microhybrid composite resin Filtek Z250 (3M ESPE), according to the manufacturer's instructions. However, to groups 5 and 6, the dentin bonding adhesive was applied prior to the resin-modified glass ionomer. The specimens were then thermocycled, cross-sectioned through the center of the restoration, fixed, and processed for scanning electron microscopy. The specimens were mounted on stubs and sputter coated. The internal adaptation of the materials to the axial wall was analyzed under SEM with × 1,000 magnification. Results: The data obtained were analyzed with nonparametric tests (Kruskal-Wallis, p ≤ .05). The null hypothesis was rejected. Calcium hydroxide and resin-modified glass ionomer applied alone or in conjunction with each other (p < .001) resulted in statistically wider microgaps than occurred when the dentin was only hybridized prior to the restoration. ©2005 BC Decker Inc.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Introduction: The evolution of light curing units can be noticed by the different systems recently introduced. The technology of LED units promises longer lifetime, without heating and with production of specific light for activation of camphorquinone. However, further studies are still required to check the real curing effectiveness of these units. Purpose: This study evaluated the microhardness of 4 shades (B-0.5, B-1, B-2 and B-3) of composite resin Filtek Z-250 (3M ESPE) after light curing with 4 light sources, being one halogen (Ultralux - Dabi Atlante) and three LED (Ultraled - Dabi Atlante, Ultrablue - DMC and Elipar Freelight - 3M ESPE). Methods: 192 specimens were distributed into 16 groups, and materials were inserted in a single increment in cylindrical templates measuring 4mm x 4mm and light cured as recommended by the manufacturer. Then, they were submitted to microhardness test on the top and bottom aspects of the cylinders. Results: The hardness values achieved were submitted to analysis of variance and to Tukey test at 5% confidence level. It was observed that microhardness of specimens varied according to the shade of the material and light sources employed. The LED appliance emitting greater light intensity provided the highest hardness values with shade B-0.5, allowing the best curing. On the other hand, appliances with low light intensity were the least effective. It was also observed that the bottom of specimens was more sensitive to changes in shade. Conclusion: Light intensity of LED light curing units is fundamental for their good functioning, especially when applied in resins with darker shades.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Introduction: The force delivered during rapid maxillary expansion (RME) produces areas of compression on the periodontal ligament of the supporting teeth. The resulting alveolar bone resorption can lead to unwanted tooth movement in the same direction. The purpose of this study was to evaluate periodontal changes by means of computed tomography after RME with tooth-tissue-borne and tooth-borne expanders. Methods: The sample comprised 8 girls, 11 to 14 years old, with Class I or II malocclusions with unilateral or bilateral posterior crossbites Four girls were treated with tooth-tissue-borne Haas-type expanders, and 4 were treated with tooth-borne Hyrax expanders. The appliances were activated up to the full 7-mm capacity of the expansion screw. Spiral CT scans were taken before expansion and after the 3-month retention period when the expander was removed. One-millimeter thick axial sections were exposed parallel to the palatal plane, comprising the dentoalveolar area and the base of the maxilla up to the inferior third of the nasal cavity. Multiplanar reconstruction was used to measure buccal and lingual bone plate thickness and buccal alveolar bone crest level by means of the computerized method. Results and Conclusions: RME reduced the buccal bone plate thickness of supporting teeth 0.6 to 0.9 mm and increased the lingual bone plate thickness 0.8 to 1.3 mm. The increase in lingual bone plate thickness of the maxillary posterior teeth was greater in the tooth-borne expansion group than in the tooth-tissue-borne group. RME induced bone dehiscences on the anchorage teeth's buccal aspect (7.1 ± 4.6 mm at the first premolars and 3.8 ± 4.4 mm at the mesiobuccal area of the first molars), especially in subjects with thinner buccal bone plates. The tooth-borne expander produced greater reduction of first premolar buccal alveolar bone crest level than did the tooth-tissue-borne expander. © 2006 American Association of Orthodontists.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper presents the overall methodology that has been used to encode both the Brazilian Portuguese WordNet (WordNet.Br) standard language-independent conceptual-semantic relations (hyponymy, co-hyponymy, meronymy, cause, and entailment) and the so-called cross-lingual conceptual-semantic relations between different wordnets. Accordingly, after contextualizing the project and outlining the current lexical database structure and statistics, it describes the WordNet.Br editing GUI that was designed to aid the linguist in carrying out the tasks of building synsets, selecting sample sentences from corpora, writing synset concept glosses, and encoding both language-independent conceptual-semantic relations and cross-lingual conceptual-semantic relations between WordNet.Br and Princeton WordNet © Springer-Verlag Berlin Heidelberg 2006.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The known diversity of dart-poison frog species has grown from 70 in the 1960s to 247 at present, with no sign that the discovery of new species will wane in the foreseeable future. Although this growth in knowledge of the diversity of this group has been accompanied by detailed investigations of many aspects of the biology of dendrobatids, their phylogenetic relationships remain poorly understood. This study was designed to test hypotheses of dendrobatid diversification by combining new and prior genotypic and phenotypic evidence in a total evidence analysis. DNA sequences were sampled for five mitochondrial and six nuclear loci (approximately 6,100 base pairs [bp]; x=3,740 bp per terminal; total dataset composed of approximately 1.55 million bp), and 174 phenotypic characters were scored from adult and larval morphology, alkaloid profiles, and behavior. These data were combined with relevant published DNA sequences. Ingroup sampling targeted several previously unsampled species, including Aromobates nocturnus, which was hypothesized previously to be the sister of all other dendrobatids. Undescribed and problematic species were sampled from multiple localities when possible. The final dataset consisted of 414 terminals: 367 ingroup terminals of 156 species and 47 outgroup terminals of 46 species. Direct optimization parsimony analysis of the equally weighted evidence resulted in 25,872 optimal trees. Forty nodes collapse in the strict consensus, with all conflict restricted to conspecific terminals. Dendrobatids were recovered as monophyletic, and their sister group consisted of Crossodactylus, Hylodes, and Megaelosia, recognized herein as Hylodidae. Among outgroup taxa, Centrolenidae was found to be the sister group of all athesphatanurans except Hylidae, Leptodactyidae was polyphyletic, Thoropa was nested within Cycloramphidae, and Ceratophryinae was paraphyletic with respect to Telmatobiinae. Among dendrobatids, the monophyly and content of Mannophryne and Phyllobates were corroborated. Aromobates nocturnus and Colostethus saltuensis were found to be nested within Nephelobates, and Minyobates was paraphyletic and nested within Dendrobates. Colostethus was shown to be rampantly nonmonophyletic, with most species falling into two unrelated cis- and trans-Andean clades. A morphologically and behaviorally diverse clade of median lingual process-possessing species was discovered. In light of these findings and the growth in knowledge of the diversity of this large clade over the past 40 years, we propose a new, monophyletic taxonomy for dendrobatids, recognizing the inclusive clade as a superfamily (Dendrobatoidea) composed of two families (one of which is new), six subfamilies (three new), and 16 genera (four new). Although poisonous frogs did not form a monophyletic group, the three poisonous lineages are all confined to the revised family Dendrobatidae, in keeping with the traditional application of this name. We also propose changes to achieve a monophyletic higher-level taxonomy for the athesphatanuran outgroup taxa. Analysis of character evolution revealed multiple origins of phytotelm-breeding, parental provisioning of nutritive oocytes for larval consumption (larval oophagy), and endotrophy. Available evidence indicates that transport of tadpoles on the dorsum of parent nurse frogs-a dendrobatid synapomorphy-is carried out primitively by male nurse frogs, with three independent origins of female transport and five independent origins of biparental transport. Reproductive amplexus is optimally explained as having been lost in the most recent common ancestor of Dendrobatoidea, with cephalic amplexus arising independently three times. © American Museum of Natural History 2006.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The purpose of this study was to evaluate in vitro three adhesive systems: a total etching single-component system (G1 Prime & Bond 2.1), a self-etching primer (G2 Clearfil SE Bond), and a self-etching adhesive (G3 One Up Bond F), through shear bond strength to enamel of human teeth, evaluating the type of fracture through stereomicroscopy, following the ISO guidance on adhesive testing. Thirty sound premolars were bisected mesiodistally and the buccal and lingual surfaces were embedded in acrylic resin, polished up to 600-grit sandpapers, and randomly assigned to three experimental groups (n = 20). Composite resin cylinders were added to the tested surfaces. The specimens were kept in distilled water (37°C/24 h), thermocycled for 500 cycles (5°C-55°C) and submitted to shear testing at a crosshead speed of 0.5 mm/min. The type of fracture was analyzed under stereomicroscopy and the data were submitted to Anova, Tukey and Chi-squared (5%) statistical analyses. The mean adhesive strengths were G1: 18.13 ± 6.49 MPa, (55% of resin cohesive fractures); G2: 17.12 ± 5.80 MPa (90% of adhesive fractures); and G3: 10.47 ± 3.14 MPa (85% of adhesive fractures). In terms of bond strength, there were no significant differences between G1 and G2, and G3 was significantly different from the other groups. G1 presented a different type of fracture from that of G2 and G3. In conclusion, although the total etching and self-etching systems presented similar shear bond strength values, the types of fracture presented by them were different, which can have clinical implications.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective: This crossover study compared the efficacy of an ultrasonic toothbrush for the reduction of plaque, gingival inflammation, and levels of Streptococcus mutans, in relation to an electric and a manual toothbrush. Materials and Methods: Twenty-one patients with orthodontic appliances were divided into three groups. All patients were evaluated by a periodontist and samples of saliva were collected for quantification of S mutans. The patients received their first brushes with appropriate instructions. For each crossover leg, patients used each toothbrush for a period of 30 days. At the end of each washout period, participants received a periodontal evaluation and new samples of saliva were collected. After 15 days of using their own toothbrushes, patients received the next toothbrushes in the experimental sequence. Results: The ultrasonic brush group presented significant improvement in the reduction of visible plaque on the buccal surfaces (-6.36%, P = .007). The counts of S mutans decreased in the electric (2.04 × 105 to 1.36 × 105 colony-forming units [CFU]/mL) and ultrasonic (2.98 × 105 to 1.84 × 105 CFU/mL) groups. There were no statistical differences among the three brushes for the clinical and microbiological parameters evaluated. Conclusions: This study did not demonstrate that the ultrasonic toothbrush was better in reducing gingival inflammation in adolescent orthodontic patients, but plaque scores were lowered on buccal surfaces of teeth with orthodontic brackets. In addition, S mutans counts were markedly decreased in the electric and ultrasonic groups, which should be related to a reduced risk of oral disease. © 2006 by The EH Angle Education and Research Foundation, Inc.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: This study compared the shear bond strength (SBS) to enamel of rest seats made with a glass-ionomer cement (Fuji IX GP Fast), a resin-modified glass-ionomer cement (Fuji II LC), and a composite resin (Z100 MP) under monotonic and cyclic loading. Materials and Methods: Rest seats were built up onto the lingual surfaces of 80 intact human mandibular incisors. Specimens (n=10) were stored in distilled water at 37°C for 30 days and subjected to shear forces in a universal testing machine (0.5 mm/min) until fracture. The SBS values were calculated (MPa) using the bonding area (9.62 mm2) delimited by adhesive tags. A staircase approach was used to determine the SBS fatigue limit of each material. Specimens were submitted to either 10,000 cycles (5 Hz) or until specimen fracture. A minimum of 15 specimens was tested for each material. Scanning electron microscopy was used to examine the mode of failure. Data were statistically analyzed with one-way ANOVA and Tukey HSD tests (α = 0.05). Results: Z100 MP yielded higher (p < 0.05) SBS (12.25 MPa) than Fuji IX GP Fast (7.21 MPa). No differences were found between Fuji II LC (10.29 MPa) and the other two materials (p > 0.05). Fuji II LC (6.54 MPa) and Z100 MP (6.26 MPa) had a similar SBS limit. Fuji IX GP Fast promoted the lowest (p < 0.05) SBS fatigue limit (2.33 MPa). All samples showed cohesive failure patterns. Conclusion: Fatigue testing can provide a better means of estimating the performance of rest seats made with dental restoratives.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This article is the first known case report of Fraser syndrome in the dental literature. Its purpose was to present the clinical manifestations, oral findings, and dental treatment of a 14-year, 10-month-old female patient. Fraser syndrome is a rare recessive autosomal genetic disorder characterized by multisystemic malformation, usually comprising cryptophthalmos, syndactyly, and renal defects. The child presented with: (1) hydrocephaly; (2) face asymmetry; (3) low-inserted ears; (4) flat nose bridge; (5) cryptophthalmos; (6) bilateral absence of eyeballs; (7) hypertelorism; (8) syndactyly on the left fingers and toes; (9) skeletal defects; and (10) lower limb asymmetry. The intraoral examination revealed: (1) complete primary denture; (2) malocclusion; (3) tooth crowding; (4) ogival palate; (5) normal labial frena; (6) absence of lingual frenum (not compromising the tongue movements); (7) parched lips; (8) supragingival calculus adhered to all tooth surfaces; and (9) moderate gingivitis. The dental treatment consisted of periodic monitoring of the patient's oral health status and supragingival scaling associated with topical applications of 0.12% chlorhexidine digluconate gel at 2-week intervals to reduce gingivitis.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective: To evaluate the marginal microleakage in enamel and dentin/cementum walls in preparations with a high C-factor, using 3 resin composite insertion techniques. The null hypothesis was that there is no difference among the 3 resin composite insertion techniques. Method and Materials: Standardized Class 5 cavities were prepared in the lingual and buccal aspects of 30 caries-free, extracted third molars. The prepared teeth were randomly assigned to 3 groups: (1) oblique incremental placement technique, (2) horizontal incremental placement technique, and (3) bulk insertion (single increment). The preparations were restored with a 1-bottle adhesive (Single Bond, 3M ESPE) and microhybrid resin composite (Z100, 3M ESPE). Specimens were isolated with nail varnish except for a 2-mm-wide rim around the restoration and thermocycled (1,000 thermal cycles, 5°C/55°C; 30-second dwell time). The specimens were immersed in an aqueous solution of 50 wt% silver nitrate for 24 hours, followed by 8 hours in a photo-developing solution and evaluated for microleakage using an ordinal scale of 0 to 4. The microleakage scores obtained from occlusal and gingival walls were analyzed with Wilcoxon and Kruskal-Wallis nonparametric tests. Results: The null hypothesis was accepted. The horizontal incremental placement technique, the oblique incremental technique, and bulk insertion resulted in statistically similar enamel and dentin microleakage scores. Conclusion: Neither the incremental techniques nor the bulk placement technique were capable of eliminating the marginal microleakage in preparations with a high C-factor.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This in vivo experimental study evaluated the efficacy of fluoride-releasing elastomers in the control of Streptococcus mutans levels in the oral cavity. Forty orthodontic patients were recruited and divided into two groups of 20. Fluoride-releasing elastomeric ligature ties (Fluor-I-Ties, Ortho Arch Co. Inc., USA) were used in the experimental group, and conventional elastomeric ligature ties (D. Morelli, Brazil), in the control group. Two initial samples of saliva were collected at a 14-day interval to determine the number of colony forming units (CFU) of Streptococcus mutans. Immediately after collecting the second sample, fluoride-releasing elastomeric ligature ties were placed in the patients of the experimental group, and conventional ligature ties, in the patients of the control group. Seven, 14 and 28 days after placement of the elastomeric ligature ties, saliva and plaque surrounding the orthodontic appliance were collected for microbiologic analysis. There were no significant differences in the number of Streptococcus mutans CFUs in saliva or plaque in the area surrounding the fluoride-releasing or conventional elastomeric ligature ties. Thus, fluoride-releasing elastomeric ligature ties should not be indicated to reduce the incidence of enamel decalcification in orthodontic patients. Since there was no significant reduction in S. mutans in saliva or plaque, other means of prevention against enamel decalcification should be indicated for these patients.