Several alloys have been used for prosthodontics restorations in the last years. These alloys have a number of metals that include gold, palladium, silver, nickel, cobalt, chromium and titanium and they are used in oral cavity undergo several corrosion. Corrosion can lead to poor esthetics, compromise of physical properties, or increased biological irritation. The objective of this study was evaluated corrosion resistance of two alloys Ni-Cr and Ni-Cr-Ti in three types of mouthwashes with different active ingredients: 0.5g/l cetylpyridinium chloride + 0.05% sodium fluoride, 0.05% sodium fluoride + 0.03% triclosan (with fluor) and 0.12% chlorohexidine digluconate. The potentiodynamic curves were performed by means of an EG&G PAR 283 potentiostat/galvanostat. The counter electrode was a platinum wire and reference electrode was an Ag/AgCl, KCl saturated. Before each experiment, working electrodes were mechanically polished with 600 and 1200 grade papers, rinsed with distilled water and dried in air. All experiments were carried out at 37.0oC in conventional three-compartment double wall glass cell containing mouthwashes. The microstructures of two alloys were observed in optical microscopy. Analysis of curves showed that Ni-Cr alloy was less reactive in the presence of 0.12% chlorohexidine digluconate while Ni-Cr-Ti alloy was more sensitive for others two types of mouthwashes (0.5g/l cetylpyridinium chloride + 0.05% sodium fluoride and 0.05% sodium fluoride + 0.03% triclosan). This occurred probably due presence of titanium in this alloy. Microstructural analysis reveals the presence of dendritic and eutectic microstructures for NiCr and Ni-Cr-Ti, respectively.
Resumo:
During clinical routine, the orthodontist uses several materials, which include metallic alloys in the form of metallic wires. However, it is necessary that the professional has some knowledge of the properties of those wires. Different types of wires are commercially available: stainless steel wires, chrome-cobalt wires, nickel-titanium wires and beta-titanium wires. Among the nickel-titanium wires, there are three subdivisions: a conventional alloy and two superelastic alloys. The superelasticity, associated to the effect of form memory, is a property used in orthodontics to initiate the dental movement in the first phase of the orthodontic treatment. This property is considered to be biologically compatible with the effective dental movement. These wires are available at the market in different transformation temperatures, and they offer the best adaptation in the groove of the bracket, simplicity and a faster treatment. However, they present little formability, and they don’t accept solder. They are also more onerous than other wires. Moreover, the low rigidity of these wires doesn’t allow them to be used for the retraction of the anterior teeth or closing of spaces. Therefore, the coherent use of superelastic orthodontic wires is recommended, accompanied by a detailed diagnosis and planning, so the result will be an efficient orthodontic correction, accomplished in a shorter period of time.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
É descrita a invenção de um método de modificação da superfície 5 de ligas de titânio empregando a oxidação anódica em ligas de Ti- 30Ta e Ti-7,5Mo para a obtenção de nanotubos perpendiculares ao substrato com diâmetro de 80-120 nm e comprimento de 100 nm-500 nm.
Resumo:
Aluminum Alloys are widely used as structural materials in the aerospace industry due to low weight, high mechanical strength and enduring corrosion resistance. Their resistance to corrosion is attributed to the rapidly formed stable oxide film (Al2O3) which spontaneously forms itself on the surface of the material. However, in the presence of aggressive ions, such as halide, Aluminum Alloys are subject to a localized process of corrosion. The electrochemical behavior of 7081-T73511 and 7050-T7451 Aluminum Alloys employed in the aerospace industry was investigated using a 0.6 M NaCl solution under the conditions of a controlled mass transport employing a rotating disk electrode. The theoretical limiting current density was determined by the Kouteki-Levich equation. The results confirmed that the inter-metallic Al7Cu2Fe acts as preferential cathode generating the galvanic coupling and the dissolution of the Aluminummatrix around it.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
A large number of metal alloys are used in Dentistry for the manufacture of fixed and removable dentures. In the oral cavity, these structures are exposed to a chemically aggressive medium, like saliva and mechanical efforts, like mastication. In addition, acidic solutions containing fluoride ions are also frequently used in dental treatments to prevent dental plates and decays development. In this context, it was considered important to investigate the influence that a fourth element could exert when added to the ternary alloy Ni-Cr-Mo, largely used in Brazil. Therefore, electrochemical tests were done to evaluate the resistance to corrosion of quaternary alloy 65Ni-25Cr-5Mo-5Ta and 65Ni-25Cr-5Mo-5W in NaF solution 0,08mol / L, pH = 4.7. For greater understanding the microstructure and morphology of alloys were studied, through metallographic analysis, using optics microscopy and electron microscopy scanning. For the electrochemical tests were applied techniques traditionally used in corrosion researches, such as: potential measures in open circuit (OCP) and cyclic polarization (CP). It was found that both quaternary alloys showed very similar results. Comparing these quaternary alloys with the ternary 65Ni-25Cr-10Mo, it was found that the quaternary alloys exhibit greater resistance to corrosion, in other words, less passivation current density than the ternary alloy, showing that it is advantageous to add a fourth element in the alloy
Resumo:
O objetivo deste trabalho foi avaliar dietas contendo diferentes doses (0, 100, 200 e 300 ppm) de probiótico sobre a produção diária de fezes (PDF) e teor de macro e microminerais nas fezes de suínos, nas fases de creche e de crescimento e no período total. A PDF, como porcentagem do peso vivo, somente apresentou diferença estatística (P<0,05) na fase inicial 1. Os teores de macro e microminerais excretados nas fezes não apresentaram diferença (P>0,05) entre tratamentos, a exceção de cálcio e sódio na fase inicial 1 e cálcio, zinco e níquel no período total. A adição de um poliprobiótico às dietas, não afetou a produção de fezes dos suínos nas fases de creche e de crescimento. Entretanto, a presença de microrganismos, adicionados (níveis de 200 e 300 ppm) às dietas reduziu a excreção fecal de cálcio, zinco e níquel.
Resumo:
O objetivo deste trabalho foi avaliar alguns atributos químicos do solo e a disponibilidade de cádmio (Cd), cromo (Cr), níquel (Ni), mercúrio (Hg), chumbo (Pb) e arsênio (As), por meio da extração pelo DTPA, em conseqüência da aplicação superficial de escória de aciaria, lama cal e lodos de esgoto centrifugados e de biodigestores, nas doses 0 (testemunha), 2, 4 e 8 Mg ha-1 e um tratamento adicional composto pela calagem superficial na dose 2 Mg ha-1. O experimento foi conduzido em delineamento de blocos ao acaso, em condições de campo, em área sob sistema plantio direto, durante 2003 e 2004. A aplicação superficial de escória de aciaria, lama cal, lodo de esgoto centrifugado e de biodigestor, até a dose 8 Mg ha-1, assim como o calcário na dose 2 Mg ha-1, não trazem problemas de disponibilidade ao ambiente, com relação aos metais pesados Cd, Cr, Hg, Pb, Ni e As, quando aplicados sobre a superfície em Latossolo Vermelho distrófico, no sistema plantio direto. A fitodisponibilidade de metais pesados às culturas da soja e aveia-preta foi nula, quando foram aplicadas doses de até 8 Mg ha-1 de lodo de esgoto, escória e lama cal sobre a superfície do solo, no sistema plantio direto.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
OBJETIVO: a reabsorção radicular apical é uma condição comumente observada durante e após o tratamento ortodôntico e fatores como tipo de aparelhagem ortodôntica utilizada, magnitude das forças aplicadas e duração do tratamento podem estar relacionados ao processo de arredondamento do ápice radicular. Buscou-se avaliar, por meio de imagens radiográficas computadorizadas, a quantidade de reabsorção no ápice radicular, quando da utilização de duas diferentes técnicas de mecânica ortodôntica fixa: Edgewise com acessórios padrão e Edgewise com acessórios totalmente programados. METODOLOGIA: a amostra constituiu-se de 20 pacientes tratados pelo mesmo profissional na Clínica de Ortodontia da Faculdade de Odontologia de Araçatuba - UNESP. Os pacientes foram divididos em dois grupos: grupo 1 (Tratados com Edgewise com acessórios padrão e fios de aço) e grupo 2 (Tratados com Edgewise com acessórios totalmente programados e fios de níquel-titânio). A avaliação radiográfica digital foi realizada por um único operador por meio de exposições radiográficas digitais feitas no início do tratamento ortodôntico, após retração de caninos e final de tratamento, utilizando o sistema de escores proposto por Levander e Malmgren (1988). RESULTADOS E CONCLUSÕES: a análise dos escores permitiu concluir que o tratamento ortodôntico empregando a técnica Edgewise com acessórios totalmente programados e fios de níquel-titânio apresentou menores graus de reabsorção radicular apical, em comparação à técnica Edgewise com acessórios padrão e fios de aço. Observou-se que, independentemente da técnica empregada, o tratamento ortodôntico como um todo apresentou um grau moderado de reabsorção radicular apical.