458 resultados para Hydrated cements
Resumo:
The objective of this study was to evaluate the chemical characteristics of the forage and ingestive behavior of Nellore heifers fed hydrolyzed sugarcane in different periods of storage. Twenty-four heifers with initial body weight of 119.6±8.1 kg were utilized. The experimental design was completely randomized, in which the treatments were diets with fresh sugarcane and hydrolyzed sugarcane (5 g of lime kg-1 of chopped sugarcane) stored for 24, 48 or 72 hours as the only roughage. The addition of lime to sugarcane associated with its storage up to 72 hours provided an increase of 20% of the potentially degradable cell wall of carbohydrates, from 382.4 to 458.8 g kg-1 of total carbohydrates. The in vitro digestibility of dry matter was altered by the storage of hydrolyzed sugarcane, increasing 7.08% when the storage time was increased from 24 to 72 hours. Heifers fed fresh sugarcane remained more time consuming compared with heifers fed other diets. The time used for water intake was not influenced by the diet. The rumination time presented a quadratic variation in relation to storage time of the hydrolyzed sugarcane, with higher values for the of hydrolyzed sugarcane diets stored for 48 hours. Heifers fed hydrolyzed sugarcane spent more time on other activities than those fed fresh sugarcane. The supply of hydrolyzed sugarcane stored up to 72 hours in the proportion of 600 g kg-1 of dry matter in the diet, alters the intake patterns, reducing the feed intake in Nellore heifers.
Resumo:
Objetivou-se estudar o efeito do tratamento alcalino da cana-de-açúcar com cal virgem ou cal hidratada sobre a composição bromatológica e a digestibilidade in vitro da matéria seca, da fibra em detergente neutro e da fibra em detergente ácido. Utilizou-se um delineamento inteiramente casualizado em esquema fatorial 3 × 3, composto de três formas de processamento da cana (in natura; cana hidrolisada com 0,5% de cal virgem; e cana hidrolisada com 0,5% de cal hidratada) e três tempos de armazenamento (12, 36 e 60 horas). As formas de processamento influenciaram os teores de matéria orgânica, matéria mineral, carboidratos totais e hemicelulose, assim como os teores de fibra em detergente neutro e nutrientes digestíveis totais. Os tempos de armazenamento influenciaram os teores de proteína bruta, matéria orgânica, carboidratos totais e hemicelulose. Entre os minerais, somente o teor de cálcio teve aumento com a inclusão de ambos os tipos de cal em relação à cana-de-açúcar, que não sofreu o processo de hidrólise. Os coeficientes de digestibilidade da matéria seca e da fibra em detergente neutro aumentaram com a hidrólise da cana em comparação à cana in natura. A hidrólise com cal hidratada ou com cal virgem mantém o valor nutricional da cana-de-açúcar, permitindo que possa ser utilizada depois de até 60 horas de armazenamento.
Resumo:
This study described the formulation and characterisation of the viscoelastic, mechanical and mucoadhesive properties of thermoresponsive, binary polymeric systems composed of poloxamer (P407) and poly(acrylic acid, C974P) that were designed for use as a drug delivery platform within the oral cavity. Monopolymeric and binary polymeric formulations were prepared containing 10, 15 and 20% (w/w) poloxamer (407) and 0.10-0.25% (w/w) poly(acrylic acid, 934P). The flow theological and viscoelastic properties of the formulations were determined using controlled stress and oscillatory rheometry, respectively, the latter as a function of temperature. The mechanical and mucoadhesive properties (namely the force required to break the bond between the formulation and a pre-hydrated mucin disc) were determined using compression and tensile analysis, respectively. Binary systems composed of 10% (w/w) P407 and C934P were elastoviscous, were easily deformed under stress and did not exhibit mucoadhesion. Formulations containing 15 or 20% (w/w) Pluronic P407 and C934P exhibited a sol-gel temperature T(sol/gel), were viscoelastic and offered high elasticity and resistance to deformation at 37 degrees C. Conversely these formulations were elastoviscous and easily deformed at temperatures below the sol-gel transition temperature. The sol-gel transition temperatures of systems containing 15% (w/w) P407 were unaffected by the presence of C934P; however, increasing the concentration of C934P decreased the T(sol/gel) in formulations containing 20%(w/w) P407. Rheological synergy between P407 and C934P at 37 degrees C was observed and was accredited to secondary interactions between these polymers, in addition to hydrophobic interactions between P407 micelles. Importantly, formulations composed of 20% (w/w) P407 and C934P exhibited pronounced mucoadhesive properties. The ease of administration (below the T(sol/gel)) in conjunction with the viscoelastic (notably high elasticity) and mucoadhesive properties (at body temperature) render the formulations composed of 20% (w/w) P407 and C934P as potentially useful platforms for mucoadhesive, controlled topical drug delivery within the oral cavity. (c) 2009 Published by Elsevier B.V.
Resumo:
The dynamics of hydration of meso and thermo citrate synthases has been investigated using the EEF1 methodology implemented with the CHARNM program. The native enzymes are composed of two identical subunits, each divided into a small and large domain. The dynamics behavior of both enzymes at 30 degrees C and 60 degrees C has been compared. The results of simulations show that during the hydration process, each subunit follows a different pathway of hydration, in spite of the identical sequence. The hydrated structures were compared with the crystalline structure, and the root mean square deviation (RMSD) of each residue along the trajectory was calculated. The regions with larger and smaller mobility were identified. In particular, helices belonging to the small domain are more mobile than those of the large domain. In contrast, the residues that constitute the active site show a much lower displacement compared with the crystalline structure. Hydration free energy calculations point out that Thermoplasma acidophilum citrate synthase (TCS) is more stable than chicken citrate synthase (CCS), at high temperatures. Such result has been ascribed to the higher number of superficial charges in the thermophilic homologue, which stabilizes the enzyme, while the mesophilic homologue denatures. These results are in accord with the experimental found that TCS keeps activity at temperatures farther apart from the catalysis regular temperature than the CCS. (c) 2005 Wiley Periodicals, Inc.
Resumo:
Bacterial cellulose (BC) hydrated membranes present nanometric reticulated structure that can be used as a template in the preparation of new organic-inorganic hybrids. BC-silica hybrids were prepared from BC membranes and tetraethoxysilane, (TEOS) at neutral pH conditions at room temperature. Macroscopically homogeneous membranes were obtained containing up to 66 wt.% of silica spheres, 20-30 nm diameter. Scanning electron micrographs clearly show the silica spheres attached to cellulose microfibrils. By removing the cellulose, the silica spheres can be easily recovered. The new hybrids are stable up to 300 degrees C and display a broad emission band under UV excitation assigned to oxygen-related defects at the silica particles surface. Emission color can be tuned by changing the excitation wavelength.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
JUSTIFICATIVA E OBJETIVOS: Diversos modelos experimentais têm sido utilizados para ilustrar as alterações hemodinâmicas e metabólicas que ocorrem durante o choque hemorrágico. O objetivo da pesquisa é o de observar os comportamentos hemodinâmicos e metabólicos que acontecem em um modelo seqüencial e progressivo de choque hemorrágico no cão, verificando quais índices alteram-se mais precocemente. MÉTODO: O estudo foi realizado em 13 cães sob anestesia venosa total com pentobarbital sódico, em normoventilação e previamente esplenectomizados. Os animais não foram hidratados e a velocidade do sangramento foi ditada pela pressão arterial em que o animal se encontrava. Os atributos estudados foram divididos em hemodinâmicos (freqüência cardíaca - FC, pressão arterial média - PAM, índice de resistência vascular sistêmica - IRVS, índice sistólico - IS, índice cardíaco - IC, índice de choque - I.choque, índice de trabalho sistólico do ventrículo esquerdo - ITSVE, pressão capilar pulmonar - PCP, pressão venosa central - PVC) e metabólicos (saturação venosa mista - SvO2, pressão venosa de oxigênio - PvO2, transporte de oxigênio - DO2, consumo de oxigênio - VO2, extração de oxigênio - TEO2, lactato sérico). A coleta de dados e os atributos foram estudados em 6 momentos distintos, sendo M1, o momento controle e os outros momentos correspondentes a decréscimos gradativos de 10% da volemia calculada para cada animal. RESULTADOS: A hemorragia determinou diminuição significativa da FC somente em M6; queda da PAM, IC, IS e ITSVE a cada momento estudado; discreta alteração da PVC e PCP em cada momento; diminuição da PvO2 e da SvO2 nos momentos estudados; redução do DO2, estabilização do VO2 e elevação da TEO2 nos momentos; o índice de choque apresentou elevação até M3, diminuição em M4 e nova elevação até M6; o IRVS elevou-se até M6, ficou inalterado em M5 e apresentou diminuição significativa em M6; o lactato apresentou elevações a partir de M5 e M6. CONCLUSÕES: Considerou-se que a pressão arterial média, freqüência cardíaca, pressão venosa central e pressão capilar pulmonar não refletem o real estado volêmico dos cães no nosso modelo experimental e que o transporte, consumo e a taxa de extração de oxigênio são parâmetros úteis na determinação da reversibilidade e prognóstico do choque hemorrágico.
Resumo:
AIM: To evaluate the host response of the gel and porous polyethylene implants in anophthalmic cavities using the B scan ultrasound.METHODS: Thirty-six white rabbits underwent unilateral enucleation with placement of gel or porous polyethylene spheres implants. The animals were submitted to clinical examination weekly and to ultrasound evaluation on 30, 60 and 90 days after surgery.RESULTS: All rabbits with gel polyethylene spheres, except one, showed implant extrusion probably because the gel spheres have hydrated and increased in volume. The B ultrasound of the gel polyethylene implant did not show vessels inside during the following period. Five animals (27.8%) with porous polyethylene spheres presented implant extrusion after 30 days of surgery. According to B ultrasound, the porous polyethylene implant showed irregular and heterogeneous architecture and reflective peaks similar to vascularized tissues.CONCLUSION: More studies are required to determine the ideal volume of gel polyethylene implant necessary to correct the diminished orbital content in the anophthalmic cavity. The B ultrasound effectiveness showed in this study for anophthalmic socket implants evaluation provides useful information for further in vivo studies and might substitute expensive methods of implants vascularization evaluation,
Resumo:
This study evaluated the effect of cycling various pH demineralizing solutions on the surface hardness, fluoride release and surface properties of restorative materials (Ketac-Fil Plus, Vitremer, Fuji II LC, Freedom and Fluorofil). Thirty specimens of each material were made and the surface hardness measured. The specimens were randomized into five groups according to the pH (4.3; 4.6; 5.0; 5.5 and 6.2) of the demineralizing solution. The specimens were submitted to pH-cycling for 15 days. The specimens remained in the demineralizing solution for six hours and in the remineralizing solution for 18 hours. Then, the surface hardness (SH) was remeasured and the surface properties were assessed. Fluoride release was determined daily. Data from SH and the percentage of alteration in surface hardness were analyzed by analysis of variance (p < 0.05); the Kruskal-Wallis test was performed for the fluoride release results. When hardness was compared, the variation in pH led to a positive correlation for glass ionomer cements and a negative correlation for fluoride release. For polyacid-modified resin composites, a negative correlation was found with regards to fluoride release; no significant correlation was observed for hardness. Surface properties were influenced: an acidic pH led to a greater alteration, except for polyacid-modified resin composites. The pH of the demineralizing solution influenced fluoride release from the tested materials. The pH variation altered hardness and surface properties of glass ionomer cements but did not influence polyacid-modified resin composites.
Resumo:
Os cimentos ionoméricos representam importante opção de material restaurador em Odontologia e sua adesão à estrutura dental, diminuindo a infiltração marginal, somada à liberação de flúor, inibindo o metabolismo de microrganismos acidogênicos e favorecendo a remineralização dental, podem diminuir a ocorrência de cárie secundária. A aplicação tópica de géis acidulados ou neutros contendo flúor tem sido largamente utilizada em Odontologia. No entanto, este procedimento pode afetar a integridade dos materiais restauradores, aumentando sua rugosidade e a retenção de placa bacteriana. Dessa forma, o presente estudo avaliou o período de tempo no qual o cimento ionomérico Vitremer mantém sua capacidade inibitória sobre Streptococcus mutans ATCC 25175 e a adesão dos mesmos sobre a superfície do material, bem como a influência da aplicação tópica de flúor acidulado e neutro sobre esses parâmetros microbiológicos e as características superficiais daquele material. Verificou-se que a atividade antimicrobiana do cimento ionomérico Vitremer se mantém por aproximadamente quatro dias e não é recuperada com o uso de flúor gel acidulado ou neutro. Observou-se, também, que Streptococcus mutans ATCC 25175 adere ao material restaurador testado sendo que a aplicação tópica de flúor não influenciou esta adesão. As características superficiais desses materiais não se alteraram com a aplicação dos géis.
Resumo:
The cementation procedure of metal-free fixed partial dentures exhibits special characteristics about the porcelains and cementation agents, which turns the correct association between these materials necessary. Our purpose in this literature review was to point the main groups of cements associated to metal-free restoration and discuss about the advantages, disadvantages, and recommendations of each one. Our search was confined to the electronic databases PubMed and SciELO and to books about this matter. There are essentially 3 types of hard cement: conventional, resin, or a hybrid of the two. The metal-free restorations can be fixed with conventional or resin cements. The right choice of luting material is of vital importance to the longevity of dental restorative materials. Conventional cements are advantageous when good compressive straight, good film thickness, and water dissolution resistance are necessary. However, they need an ideal preparation, and they are not acid dissolution resistant. Conventional cements are indicated to porcelains that cannot be acid etched. Resin cements represent the choice to metal-free restoration cementation because they present better physical properties and aesthetic than conventional agents.
Resumo:
This in vitro study evaluated the effect of a prolonged erosive pH cycling on the superficial microhardness change (SMHC) and the erosive wear of different restorative materials. Eighty enamel specimens with prepared cavities of 1.5 x 1.5 mm were randomly divided into eight groups according to the restorative materials used for the fillings (RMGI - resin-modified glass-ionomer, CGI - conventional glass-ionomer, CR- composite resin, A - amalgam) and immersion media used (ERO - erosive medium or SAL - artificial saliva). During 35 days, half of the specimens were immersed in a cola drink (ERO), for 5 min, three times a day, and they remained in SAL between the erosive cycles. The other half of the specimens was immersed in SAL only, for the entire experimental period (control). Data were tested for significant differences by anova and Tukey's tests (P < 0.05). Scanning electron microscopy images were made to illustrate the enamel erosive wear and restorative materials alterations. The mean SMHC (%) and mean erosive wear (mu m) of the materials were: RMGI-ERO (30/0.5); CGI-ERO (37/0.5); CR-ERO (-0.3/0.3); A-ERO (-4/0.3); RMGI-SAL (4/0.4); CGI-SAL (-6/0.4); CR-SAL (-3/0.2) and A-SAL (2/0.4). Scanning electron microscopy images showed pronounced enamel erosive wear on groups submitted to erosive pH cycling when compared with groups maintained in saliva. In conclusion, the prolonged pH cycling promoted significantly higher alterations (SMHC and erosive wear) on the glass-ionomer cements than the CR and amalgam.
Resumo:
Foi propósito deste estudo analisar a influência da infiltração marginal coronária no comportamento dos tecidos periapicais de dentes de cães após obturação de canal e preparo para pino. Quarenta canais de dentes de cães foram instrumentados e obturados pela técnica da condensação lateral com cones de guta percha e os cimentos Roth e Sealer 26. Após preparo para pino, o remanescente da obturação foi protegido ou não com um plug do cimento temporário Lumicon. Após exposição ao meio oral por 90 dias, os animais foram sacrificados e as peças preparadas para análise histomorfológica. A técnica de Brown e Brenn mostrou 70% de casos com infiltração de microrganismos para o cimento Roth e 20% com o Sealer 26. Quando um plug de Lumicon foi empregado ocorreu 30% de casos de infiltração de microrganismos com o cimento Roth e 0,0% com o cimento Sealer 26. Reação inflamatória crônica foi mais freqüentemente observada com o cimento Roth do que com o Sealer 26. Foi concluído que o plug de Lumicon é eficiente no controle da infiltração coronária (p=0.05) e que o Sealer 26 foi mais biocompatível e selou melhor os canais radiculares do que o cimento Roth (p=0.01).
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
There are several studies about the cytotoxic effects of dental materials in contact with the pulp tissue, such as calcium hydroxide (CH), adhesive systems, resin composite and glass ionomer cements. The aim of this review article was to summarize and discuss the cytotoxicity and biocompatibility of materials used for protection of the dentin-pulp complex, some components of resin composites and adhesive systems when placed in direct or indirect contact with the pulp tissue. A large number of dental materials present cytotoxic effects when applied close or directly to the pulp, and the only material that seems to stimulate early pulp repair and dentin hard tissue barrier formation is CH.