189 resultados para Glass preparation


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: To evaluate the root fracture strength of human single-rooted premolars restored with customized fiberglass post-core systems after fatigue simulation. Methods: 40 human premolars had their crowns cut and the root length was standardized to 13 mm. The teeth were endodontically treated and embedded in acrylic resin. The specimens were distributed into four groups (n=10) according to the restorative material used: prefabricated fiber post (PFP), PFP+accessory fiber posts (PFPa), PFP+unidirectional fiberglass (PFPf), and unidirectional fiberglass customized post (CP). All posts were luted using resin cement and the cores were built up with a resin composite. The samples were stored for 24 hours at 37 degrees C and 100% relative humidity and then submitted to mechanical cycling. The specimens were then compressive-loaded in a universal testing machine at a crosshead speed of 0.5 mm/minute until fracture. The failure patterns were analyzed and classified. Data was submitted to one-way ANOVA and Tukey's test (alpha= 0.05). Results: The mean values of maximum load (N) were: PFP - 811.4 +/- 124.3; PFPa - 729.2 +/- 157.2; PFPf - 747.5 +/- 204.7; CP - 762.4 +/- 110. Statistical differences were not observed among the groups. All groups showed favorable restorable failures. Fiberglass customized post did not show improved fracture resistance or differences in failure patterns when compared to prefabricated glass fiber posts. (Am J Dent 2012;25:35-38).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of this study was to compare the incidence of dentinal defects (fractures and craze lines) after canal preparation with different nickel-titanium rotary files. Two hundred sixty mandibular premolars were selected. Forty teeth were left unprepared (n = 40). The other teeth were prepared either with manual Flexofiles (n = 20) or with different rotary files systems: ProTaper (Dentsply-Maillefer, Ballaigues, Switzerland), ProFile (Dentsply-Maillefer), SystemGT (Dentsply-Maillefer), or S-ApeX (FKG Dentaire, La Chaux-de-Fonds, Switzerland) (n = 50 each). Roots were then sectioned 3, 6, and 9 mm from the apex and observed under a microscope. The presence of dentinal defects was noted. There was a significant difference in the appearance of defects between the groups (p < 0.05). No defects were found in the unprepared roots and those prepared with hand files and S-ApeX. ProTaper, ProFile, and GT preparations resulted in dentinal defects in 16%, 8%, and 4% of teeth, respectively. Some endodontic preparation methods might damage the root and induce dentinal defects. (J Endod 2009;35:236-238)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives. The purpose of this paper is to modify the conventional calcium fluoro-aluminosilicate glass, which is used in the formation of glass ionomer cements (CIGs) by the niobium addition and to study the properties of GICs obtained.Materials and methods. Sol-gel process was used to prepare the powder at lower temperature than fusion method. Glass-ceramic powder obtained in this way was used to prepare the GICs. The properties such as working and setting times, microhardness and diametral tensile strength were evaluated for the experimental GICs and a commercial luting cement.Results. The ideal powder:liquid (P:L) ratio determined to prepare the experimental GICs was equal to 1:1. The cements prepared using this ratio showed working and setting times similar to the commercial GICs. in mechanical tests it was observed that microhardness and diametral tensile strength of the experimental GICs decreased significantly with the reduction of P:L ratio. on the other hand, the results obtained in microhardness tests indicated that the presence of niobium was a positive factor.Significance. The chemical process allows the development of glass-ceramic powder at 600 degrees C which is the goal of the present paper. It was concluded that GICs containing niobium might be used in dental applications and these results encourage further researches on other compositions. (c) 2007 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aim To evaluate differences between anatomic and radiographic measurements of root canal wall thickness (RCWT) after each root canal preparation stage during post placement.Methodology Twenty mandibular premolars with a single canal were decoronated and the roots embedded in resin using a teflon muffle. Roots were sectioned horizontally at a pre-established level and canals were prepared for post placement. Endodontic hand files were used for root canal preparation, followed by Gates Glidden drills and Peeso reamers. Standardized radiographs and photographs at pre-established measurement levels were taken before preparation, after root canal instrumentation, after Gates Glidden preparation and after Peeso enlargement. All images were digitized and RCWT at the mesial and distal walls measured (IMAGETOOL 3.0). Differences between radiographic and anatomic measurements were analysed with paired t-tests. ANOVA was used to compare the percentages of radiographic distortions.Results Regardless of the time-point evaluated, RCWT determined by radiographs were greater than the respective anatomic measurements (P < 0.05). The difference detected at each stage was similar and constant (P > 0.05).Conclusions Throughout preparation for post placement, radiographic images overestimated the RCWT by approximately 25%, regardless of the clinical stage evaluated.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aqueous extract of Casearia sylvestris (Flacourtiaceae) has been shown to inhibit enzymatic and biological properties of some Bothrops and Crotalus venoms and their purified phospholipase A(2) (PLA(2)) toxins. In this work we evaluated the influence of C sylvestris aqueous extract upon neuromuscular blocking and muscle damaging activities of some PLA(2)S (crotoxin from C. durissus terrificus, bothropstoxin-I from B.jararacussu, piratoxin-I from B. pirajai and myotoxin-II from B. moojeni) in mouse phrenic-diaphragm preparations. Crotoxin (0.5 mu M) and all other PLA2 toxins (1.0 mu M) induced irreversible and time-dependent blockade of twitches. Except for crotoxin, all PLA2 toxins induced significant muscle damage indices, assessed by microscopic analysis. Preincubation of bothropstoxin-I, piratoxin-I or myotoxin-II with C. sylvestris extract (1:5 (w/w), 30 min, 37 degrees C significantly prevented the neuromuscular blockade of preparations exposed to the mixtures for 90 min; the extent of protection ranged from 93% to 97%. The vegetal extract also neutralized the muscle damage (protection of 80-95%). Higher concentration of the C. sylvestris extract (1: 10, w/w) was necessary to neutralize by 90% the neuromuscular blockade induced by crotoxin. These findings expanded the spectrum of C. sylvestris antivenom activities, evidencing that it may be a good source of potentially useful PLA2 inhibitors. (c) 2007 Elsevier B.V.. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work describes a modified sol-gel method for the preparation of V2O5/TiO2 catalysts. The samples have been characterized by N-2 adsorption at 77 K, X-ray Diffractometry (XRD), Scanning Electronic Microscopy (SEM/EDX) and Fourier Transform Infrared Spectroscopy (FT-IR). The surface area increases with the vanadia loading from 24 m(2) g(-1) for pure TiO2 to 87 m(2) g(-1) for 9 wt% of V2O5. The rutile form is predominant for pure TiO2 but becomes enriched with anatase phase when vanadia loading is increased. No crystalline V2O5 phase was observed in the diffractograms of the catalysts. Analysis by SEM showed heterogeneous granulation of particles with high vanadium dispersion. Two species of surface vanadium were observed by FT-IR spectroscopy: a monomeric vanadyl and polymeric vanadates. The vanadyl/vanadate ratio remains practically constant. Ethanol oxidation was used as a catalytic test in a temperature range from 350 to 560 K. The catalytic activity starts around 380 K. For the sample with 9 wt% of vanadia, the conversion of ethanol into acetaldehyde as the main product was approximately 90% at 473 K.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Several factors render carotenoid determination inherently difficult. Thus, in spite of advances in analytical instrumentation, discrepancies in quantitative results on carotenoids can be encountered in the international literature. A good part of the errors comes from the pre-chromatographic steps such as sampling scheme that does not yield samples representative of the food lots under investigation; sample preparation which does not maintain representativity and guarantee homogeneity of the analytical sample; incomplete extraction; physical losses of carotenoids during the various steps, especially during partition or washing and by adsorption to glass walls of containers; isomerization and oxidation of carotenoids during analysis. on the otherhand, although currently considered the method of choice for carotenoids, high performance liquid chromatography (HPLC) is subject to various sources of errors, such as: incompatibility of the injection solvent and the mobile phase, resulting in distorted or split peaks; erroneous identification; unavailability, impurity and instability of carotenoid standards; quantification of highly overlapping peaks; low recovery from the HPLC column; errors in the preparation of standard solutions and in the calibration procedure; calculation errors. Illustrations of the possible errors in the quantification of carotenoids by HPLC are presented.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: To evaluate the effect of airborne-particle abrasion and mechanico-thermal cycling on the flexural strength of a ceramic fused to cobalt-chromium alloy or gold alloy.Materials and Methods: Metallic bars (n = 120) were made (25 mm x 3 mm x 0.5 mm): 60 with gold alloy and 60 with Co-Cr. At the central area of the bars (8 mm x 3 mm), a layer of opaque ceramic and then two layers of glass ceramic (Vita VM13, Vita Zahnfabrick) were fired onto it (thickness: 1 mm). Ten specimens from each alloy group were randomly allocated to a surface treatment [(tungsten bur or air-particle abrasion (APA) with Al(2)O(3) at 10 mm or 20 mm away)] and mechanico-thermal cycling (no cycling or mechanically loaded 20,000 cycles; 10 N distilled water at 37 degrees C and then thermocycled 3000 cycles; 5 degrees C to 55 degrees C, dwell time 30 seconds) combination. Those specimens that did not undergo mechanico-thermal cyclingwere stored inwater (37 degrees C) for 24 hours. Bond strength was measured using a three-point bend test, according to ISO 9693. After the flexural strength test, failure types were noted. The data were analyzed using three factor-ANOVA and Tukey's test (alpha = 0.05).Results: There were no significant differences between the flexural bond strength of gold and Co-Cr groups (42.64 +/- 8.25 and 43.39 +/- 10.89 MPa, respectively). APA 10 and 20 mm away surface treatment (45.86 +/- 9.31 and 46.38 +/- 8.89 MPa, respectively) had similar mean flexural strength values, and both had significantly higher bond strength than tungsten bur treatment (36.81 +/- 7.60 MPa). Mechanico-thermal cycling decreased the mean flexural strength values significantly for all six alloy-surface treatment combinations tested when compared to the control groups. The failure type was adhesive in the metal/ceramic interface for specimens surface treated only with the tungsten bur, and mixed for specimens surface treated with APA 10 and 20 mm.Conclusions: Considering the levels adopted in this study, the alloy did not affect the bond strength; APA with Al(2)O(3) at 10 and 20 mm improved the flexural bond strength between ceramics and alloys used, and the mechanico-thermal cycling of metal-ceramic specimens resulted in a decrease of bond strength.