142 resultados para Frei Aleixo de Meneses


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background Toxoplasmosis is a zoonosis caused by an obligate intracellular parasite, Toxoplasma gondii, which affects warm-blooded animals including humans. Its prevalence rates usually vary in different regions of the planet. Methods In this study, an analysis of the seroprevalence of toxoplasmosis among Brazilian students was proposed by means of IgG specific antibodies detection. The presence of anti-Toxoplasma gondiiantibodies by indirect fluorescent antibody test (IFAT) was also evaluated in order to compare it with enzyme-linked immunosorbent assay (ELISA) and to assess the use of 2,2′-azinobis(3-ethylbenzothiazoline-6-sulfonic acid) and o-phenylenediamine dihydrochloride chromogens. Results The IFAT method showed a seroprevalence of 22.3%. These results were similar to those obtained by ELISA (24.1%). The seroprevalence was directly estimated from the IgG avidity, which showed that in a sample of 112 students, three of them had acute infection, an incidence of 1.6% in the studied population. Conclusion In this study, the use of different chromogenic substrates in immunoenzymatic ELISA assays did not display different sensitivity in the detection of T. gondii-reagent serum. The extrapolation of results to this population must be carefully considered, since the investigation was conducted on a reduced sample. However, it allows us to emphasize the importance of careful and well prepared studies to identify risk factors for toxoplasmosis, to adopt preventive measures and to offer guidance to at-risk populations about the disease.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In this paper we present the results of a coherent narrow-band search for continuous gravitational-wave signals from the Crab and Vela pulsars conducted on Virgo VSR4 data. In order to take into account a possible small mismatch between the gravitational-wave frequency and two times the star rotation frequency, inferred from measurement of the electromagnetic pulse rate, a range of 0.02 Hz around two times the star rotational frequency has been searched for both the pulsars. No evidence for a signal has been found and 95% confidence level upper limits have been computed assuming both that polarization parameters are completely unknown and that they are known with some uncertainty, as derived from x-ray observations of the pulsar wind torii. For Vela the upper limits are comparable to the spin-down limit, computed assuming that all the observed spin-down is due to the emission of gravitational waves. For Crab the upper limits are about a factor of 2 below the spin-down limit, and represent a significant improvement with respect to past analysis. This is the first time the spin-down limit is significantly overcome in a narrow-band search.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We present results of a search for continuously emitted gravitational radiation, directed at the brightest low-mass x-ray binary, Scorpius X-1. Our semicoherent analysis covers 10 days of LIGO S5 data ranging from 50-550 Hz, and performs an incoherent sum of coherent F-statistic power distributed amongst frequency-modulated orbital sidebands. All candidates not removed at the veto stage were found to be consistent with noise at a 1% false alarm rate. We present Bayesian 95% confidence upper limits on gravitational-wave strain amplitude using two different prior distributions: a standard one, with no a priori assumptions about the orientation of Scorpius X-1; and an angle-restricted one, using a prior derived from electromagnetic observations. Median strain upper limits of 1.3 x 10(-24) and 8 x 10(-25) are reported at 150 Hz for the standard and angle-restricted searches respectively. This proof-of-principle analysis was limited to a short observation time by unknown effects of accretion on the intrinsic spin frequency of the neutron star, but improves upon previous upper limits by factors of similar to 1.4 for the standard, and 2.3 for the angle-restricted search at the sensitive region of the detector.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The Advanced LIGO gravitational wave detectors are second-generation instruments designed and built for the two LIGO observatories in Hanford, WA and Livingston, LA, USA. The two instruments are identical in design, and are specialized versions of a Michelson interferometer with 4 km long arms. As in Initial LIGO, Fabry-Perot cavities are used in the arms to increase the interaction time with a gravitational wave, and power recycling is used to increase the effective laser power. Signal recycling has been added in Advanced LIGO to improve the frequency response. In the most sensitive frequency region around 100 Hz, the design strain sensitivity is a factor of 10 better than Initial LIGO. In addition, the low frequency end of the sensitivity band is moved from 40 Hz down to 10 Hz. All interferometer components have been replaced with improved technologies to achieve this sensitivity gain. Much better seismic isolation and test mass suspensions are responsible for the gains at lower frequencies. Higher laser power, larger test masses and improved mirror coatings lead to the improved sensitivity at mid and high frequencies. Data collecting runs with these new instruments are planned to begin in mid-2015.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In order to better understand the natural history of chronic functional constipation, a questionnaire was applied to 163 children and infants, before beginning standardized treatment. Median age (range) at start was 3 mo(0-108 mo) but age at arrival at the Pediatric Gastroenterology Unit was 53 mo(2-146 mo). In 62.4% of the cases symptoms began before or up to 3 mo after cow's milk introduction and rarely around (-/+ 6 mo) toilet training. Possible complications appeared progressively, often at preschool or school age or as the first noticeable manifestation: recurrent abdominal pain (61.1%), fecal soiling (45.4%), fecal blood (35%), enuresis (23.3%), vomiting (19%), urinary infection (17.9%), urinary retention (8.6%). Abdominal distension was rarely detected on physical examination and was usually discrete. In conclusion, children attended in Botucatu begin their constipation at an early age, frequently associated with weaning,and important complications may ensue along years. This evolution should be avoided by prevention and early treatment of constipation.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This study evaluated the influence of light sources and immersion media on the color stability of a nanofilled composite resin. Conventional halogen, high-power-density halogen and high-power-density light-emitting diode (LED) units were used. There were 4 immersion media: coffee, tea, Coke® and artificial saliva. A total of 180 specimens (10 mm x 2 mm) were prepared, immersed in artificial saliva for 24 h at 37±1ºC, and had their initial color measured with a spectrophotometer according to the CIELab system. Then, the specimens were immersed in the 4 media during 60 days. Data from the color change and luminosity were collected and subjected to statistical analysis by the Kruskall-Wallis test (p<0.05). For immersion time, the data were subjected to two-way ANOVA test and Fisher's test (p<0.05). High-power-density LED (ΔE=1.91) promoted similar color stability of the composite resin to that of the tested halogen curing units (Jet Lite 4000 plus--ΔE=2.05; XL 3000--ΔE=2.28). Coffee (ΔE=8.40; ΔL=-5.21) showed the highest influence on color stability of the studied composite resin. There was no significant difference in color stability regardless of the light sources, and coffee was the immersion medium that promoted the highest color changes on the tested composite resin.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of this study was to analyze, through Vickers hardness test and photoelasticity analysis, pre-bent areas, manually bent areas, and areas without bends of 10-mm advancement pre-bent titanium plates (Leibinger system). The work was divided into three groups: group I-region without bend, group II-region of 90° manual bend, and group III-region of 90° pre-fabricated bends. All the materials were evaluated through hardness analysis by the Vickers hardness test, stress analysis by residual images obtained in a polariscope, and photoelastic analysis by reflection during the manual bending. The data obtained from the hardness tests were statistically analyzed using ANOVA and Tukey's tests at a significance level of 5 %. The pre-bent plate (group III) showed hardness means statistically significantly higher (P < 0.05) than those of the other groups (I-region without bends, II-90° manually bent region). Through the study of photoelastic reflection, it was possible to identify that the stress gradually increased, reaching a pink color (1.81 δ / λ), as the bending was performed. A general analysis of the results showed that the bent plate region of pre-bent titanium presented the best results.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Preterm infants in neonatal intensive care units frequently receive red blood cells (RBC) transfusions due to the anemia of prematurity. A number of variables related to gestational age, severity of illness and transfusion practices adopted in the neonatal unit where the neonate was born may contribute to the prescription of RBC transfusions. This study aimed to analyse the frequency and factors associated with RBC transfusions in very-low-birth-weight preterm infants. A prospective cohort of 4283 preterm infants (gestational age: 29.9 ± 2.9 weeks; birth weight: 1084 ± 275 g) carried out at 16 university hospitals in Brazil between January 2009 and December 2011 was analysed. Factors associated with RBC transfusions were evaluated using univariate and multiple logistic regression analysis. A total of 2208 (51.6%) infants received RBC transfusions (variation per neonatal unit: 34.1% to 66.4%). RBC transfusions were significantly associated with gestational age (OR: -1.098; 95%CI: -1.12 to -1.04), SNAPPE II score (1.01; 1.00-1.02), apnea (1.69; 1.34-2.14), pulmonary hemorrhage (2.65; 1.74-4.031), need for oxygen at 28 days of life (1.56; 1.17-2.08), clinical sepsis (3.22; 2.55-4.05), necrotising enterocolitis (3.80; 2.26-6.41), grades III/IV intraventricular hemorrhage (1.64; 1.05-2.58), mechanical ventilation (2.27; 1.74-2.97), use of umbilical catheter (1.86; 1.35-2.57), parenteral nutrition (2.06; 1.27-3.33), >60 days of hospitalization (5.29; 4.02-6.95) and the neonatal unit where the neonate was born. The frequency of RBC transfusions varied among neonatal intensive care units. Even after adjusting for adverse health conditions and therapeutic interventions, the neonatal unit continued to influence transfusion practices in very-low birth-weight infants.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Pós-graduação em Agronomia (Energia na Agricultura) - FCA

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This study evaluated the influence of light sources and immersion media on the color stability of a nanofilled composite resin. Conventional halogen, high-power-density halogen and high-power-density light-emitting diode (LED) units were used. There were 4 immersion media: coffee, tea, Coke® and artificial saliva. A total of 180 specimens (10 mm x 2 mm) were prepared, immersed in artificial saliva for 24 h at 37±1ºC, and had their initial color measured with a spectrophotometer according to the CIELab system. Then, the specimens were immersed in the 4 media during 60 days. Data from the color change and luminosity were collected and subjected to statistical analysis by the Kruskall-Wallis test (p<0.05). For immersion time, the data were subjected to two-way ANOVA test and Fisher's test (p<0.05). High-power-density LED (ΔE=1.91) promoted similar color stability of the composite resin to that of the tested halogen curing units (Jet Lite 4000 plus--ΔE=2.05; XL 3000--ΔE=2.28). Coffee (ΔE=8.40; ΔL=-5.21) showed the highest influence on color stability of the studied composite resin. There was no significant difference in color stability regardless of the light sources, and coffee was the immersion medium that promoted the highest color changes on the tested composite resin.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Introdução: Na sociedade contemporânea costuma-se associar Design ao consumo de luxo, entretanto o design encontra-se aplicado a todos os objetos, do automóvel ao clips, todavia o Design parece estar sempre atrelado à sociedade de consumo, à indústria a serviço do capital e das relações de subordinação e expropriação a ele atrelado. Assim faz-se necessário despertar no aluno do curso de Design a possibilidade da aplicação de seu conhecimento a serviço de uma sociedade mais democrática e solidária, de não apenas produzir a serviço do capital, mas pensar de forma mais abrangente, considerando o bem comum. Objetivos: O Labsol, desde 2007, procura: Otimizar, revitalizar e qualificar a produção artesanal através dos conceitos de ecodesign, sustentabilidade e economia solidária, tendo em vista a auto sustentabilidade das comunidades produtoras. Desenvolver projetos e ações que promovam encontros entre o Design e o patrimônio cultural do artesanato. Preocupar-se com a qualificação do produto artesanal e sua inserção no mercado, tendo em vista a auto sustentabilidade das comunidades produtoras. Métodos: A formação dos integrantes do LabSol é continua e baseada em três conceitos fundamentais: sustentabilidade, economia solidária e eco design. As ações se dão a partir do convite de uma comunidade de artesãos na perspectiva da qualificação estética ou produtiva de seus trabalhos e a melhoria da geração de renda. Utiliza-se o método empírico, de caráter prático, através de estudo de caso. Em uma visita aprende-se métodos e técnicas utilizados pela comunidade, e de volta à sede, faz-se revisão bibliográfica e utiliza-se a metodologia do projeto em design para melhoria das técnicas produção, o redesenho de produtos e a geração de novos objetos de design. Construídos modelos e protótipos e avaliado seu potencial de comercialização são submetidos a aprovação da comuni-dade através de oficinas. O diferencial no trabalho do LabSol se dá na maneira que os projetos são entregues aos grupos. Entende-se todo o processo como um aprendizado de mão dupla, da troca de saberes, onde os membros do laboratório aprendem da comunidade dados de sua cultura e de seus modos de fazer, em contrapartida novos produtos são levados de volta a comunidade, entendidos como mais um dado cultural posto a disposição da comunidade podendo ou não ser por ela incorporado. Resultados: Com mais de 20 grupos atendidos, e centenas de produtos de eco design, as ações o LabSol resultam na pesquisa de eco design, materiais, técnicas, métodos e de novas tecnologias sociais, gerando um número significativo de publicações e exposições de divulgação. Tem recebido graduandos de relações públicas e engenharia de produção, a junção de saberes tem permitido um aprimoramento na qualidade de atendimento ás comunidades.