139 resultados para Fluorescence sensors


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Thin films of the bis[2,3,9,10,16,17,23,24-octachlorophthalocyaninate] lutetium(III) complex (LuPc2Cl32) have been prepared by the Langmuir-Blodgett and the Langmuir-Schaefer (LS) techniques. The influence of the chlorine substituents in the structure of the films and in their spectroscopic, electrochemical and sensing properties has been evaluated. The pi-A isotherms exhibit a monolayer stability greater than the observed in the unsubstituted analogue (LuPc2), being easily transferred to solid substrates, also in contrast to LuPc2. The LB and LS films present a linear growth forming stratified layers, monitored by UV-VIS absorption spectroscopy. The latter also revealed the presence of LuPc2Cl32 in the form of monomers and aggregates in both films. The FTIR data showed that the LuPc2Cl32 molecules present a non-preferential arrangement in both films. Monolayers of LB and LS were deposited onto 6 nm Ag island films to record surface-enhanced resonance Raman scattering (SERRS), leading to enhancement factors close to 2 x 10(3). Finally, LB and LS films deposited onto ITO glass have been successfully used as voltammetric sensors for the detection of catechol. The improved electroactivity of the LB and LS films has been confirmed by the reduction of the overpotential of the oxidation of catechol. The enhancement of the electrocatalytic effect observed in LB and LS films is the result of the nanostructured arrangement of the surface which increases the number of active sites. The sensors show a limit of detection in the range of 10(-5) mol/L.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study describes the use of micro synchrotron radiation X-ray fluorescence (µSR-XRF) to investigate citrus greening disease in sweet orange (Citrus sinensis) plants. An experiment using healthy plants as control and plants of the same variety infected with Candidatus Liberibacter asiaticus (CLas) was performed to verify variations of the mineral composition of citrus leaves. A µSR-XRF system using the D09B X-ray fluorescence beam line at the Brazilian Synchrotron Light Source (LNLS, Campinas, São Paulo State) was employed for this purpose. The data were analyzed using a chemometric tool called soft independent modelling of class analogy (SIMCA). The promising results from SIMCA models reinforce the evidence that plants infected by citrus greening (both asymptomatic and symptomatic) undergo alterations in their micro- and macronutrient compositions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Covalent “click” cycloaddition was used to functionalize silica substrates with pH-sensitive nanoparticles, thus producing uniform and highly luminescent analytical devices usable in both commercial fluorimeters and fluorescence microscopes. Quantitative and spatially-resolved extracellular pH measurements were successfully achieved on live cardiac fibroblasts with these novel ion-sensitive surfaces.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To evaluate the performance of a pen‑type laser fluorescence device (DIAGNOdent 2190; LFpen, KaVo, Germany) and bitewing radiographs (BW) for approximal caries detection in permanent and primary teeth. Materials and Methods: A total of 246 anterior approximal surfaces (102 permanent and 144 primary) were selected. Contact points were simulated using sound teeth. Two examiners assessed all approximal surfaces using LFpen and BW. The teeth were histologically assessed for the reference standard. Optimal cut‑off limits were calculated for LFpen for primary and permanent teeth. Sensitivity, specificity, accuracy and area under the receiver operating characteristic curve (Az) were calculated for D1 (enamel and dentin lesions) and D3 (dentin lesions) thresholds. The reproducibility was assessed by intraclass correlation coefficient (ICC) and Cohen's weighted kappa values. Results: For permanent teeth, the LFpen cut‑off were 0– 27 (sound), 28– 33 (enamel caries) and >33 (dentin caries). For primary teeth, the LFpen cut‑off were 0– 7 (sound), 8– 32 (enamelcaries) and >32 (dentin caries). The LFpen presented higher sensitivity values than BW for primary teeth (0.58 vs. 0.32 at D1 and 0.80 vs. 0.47 at D3) and permanent teeth (0.80 vs. 0.57 at D1 and 0.94 vs. 0.51 at D3). Specificity did not show a significant difference between the methods. Rank correlations with histology were 0.59 and 0.83 (LFpen) and 0.36 and 0.70 (BW) for primary and permanent teeth, respectively, considering all lesions. ICC values for LFpen were 0.71 (inter) and 0.86 (intra) for permanent teeth and 0.94 (inter) and 0.90/0.99 for primary teeth. Kappa values for BW were 0.69 (inter) and 0.68/0.90 (intra) for permanent teeth and 0.64 (inter) and 0.89/0.89 for primary teeth. Conclusion: LFpen presented better reproducibility for primary and permanent teeth and higher accuracy in detecting caries lesions at D1 threshold than BW for permanent teeth. LFpen should be used as an adjunct method for approximal caries detection.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The human dentition is naturally translucent, opalescent and fluorescent. Differences between the level of fluorescence of tooth structure and restorative materials may result in distinct metameric properties and consequently perceptible disparate esthetic behavior, which impairs the esthetic result of the restorations, frustrating both patients and staff. In this study, we evaluated the level of fluorescence of different composites (Durafill in tones A2 (Du), Charisma in tones A2 (Ch), Venus in tone A2 (Ve), Opallis enamel and dentin in tones A2 (OPD and OPE), Point 4 in tones A2 (P4), Z100 in tones A2 ( Z1), Z250 in tones A2 (Z2), Te-Econom in tones A2 (TE), Tetric Ceram in tones A2 (TC), Tetric Ceram N in tones A1, A2, A4 (TN1, TN2, TN4), Four seasons enamel and dentin in tones A2 (and 4SD 4SE), Empress Direct enamel and dentin in tones A2 (EDE and EDD) and Brilliant in tones A2 (Br)). Cylindrical specimens were prepared, coded and photographed in a standardized manner with a Canon EOS digital camera (400 ISO, 2.8 aperture and 1/ 30 speed), in a dark environment under the action of UV light (25 W). The images were analyzed with the software ScanWhite©-DMC/Darwin systems. The results showed statistical differences between the groups (p < 0.05), and between these same groups and the average fluorescence of the dentition of young (18 to 25 years) and adults (40 to 45 years) taken as control. It can be concluded that: Composites Z100, Z250 (3M ESPE) and Point 4 (Kerr) do not match with the fluorescence of human dentition and the fluorescence of the materials was found to be affected by their own tone.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Chlorophyll fluorescence is currently used as a rapid diagnostic and nondestructive method to detect and quantify damage on the photosynthetic apparatus of leaves on weeds, crops and ornamental/coniferous trees in response to both environmental stress and herbicides. This study aimed to evaluate chlorophyll fluorescence in guanandi plants (Calophyllum brasiliense) after application of different postemergence herbicides. The experiment was performed in a completely randomized design, with six treatments (control, bentazon, sulfentrazone, isoxaflutole, atrazine and glyphosate) and five replications. The herbicide treatments were applied with a stationary sprayer, and electron transport rate (ETR) was subsequently analyzed with OS5p Multi-Mode Chlorophyll Fluorometer. In the monitored period, guanandi plants subjected to atrazine showed higher sensitivity to chlorophyll fluorescence than the other treatments. Although bentazon is a photosystem II inhibitor, it showed no major changes in electron transport for the studied species and in the monitored period. In summary, ETR is a good parameter to evaluate the effect of some herbicides on Calophyllum brasiliense plants.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objective of this study was to evaluate the color, translucency and fluorescence of bovine enamel and dentin submitted to different bleaching modalities. Pairs of enamel and dentin discs (3 mm in diameter) were obtained from 150 bovine teeth. In 75 of the pairs, one specimen had the enamel removed (Dentin Group). The dentin was removed from one specimen of the remaining 75 pairs (Enamel Group) and the other specimen was left unaltered (Enamel + Dentin). The evaluation of color, translucency and fluorescence was performed with a spectrophotometer using the CIE L* a* b*. Each group was subdivided into three subgroups: Control, composed of specimens that were not bleached, and two experimental subgroups, bleached with either 10% carbamide peroxide (CP10%) or 35% hydrogen peroxide (HP35%). The CP10% bleaching gel was applied 2 h/day for 14 days. The HP35% bleaching agent was applied using two applications of 30 min each, with a one week interval between each application. When not being bleached, the specimens were immersed in artificial saliva. The color, translucency and fluorescence ratings were assessed using spectrophotometry 7 days after the treatment. Regarding color, significant differences were found between bleaching techniques in the groups Enamel and Enamel + Dentin, with a higher color difference for HP35%. Bleaching did not change the translucency of the dental tissues. There were significant differences for fluorescence for the HP35% subgroups of Dentin and Enamel + Dentin, and for the CP10% subgroup of Enamel. Dental bleaching changed the color and fluorescence of the dental tissues, however translucency was not affected.